Records from 2003 to 2004. Most recent: inspection, 15 January 2004.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Lifejacket/PFD (General)
Issued 13 August 2003
Resolved
Life preservers do not have lights affixed to them. LEGACY COMPONENT DESC: Lights
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 15 January 2004
Documentation › Logs/Records
Issued 13 August 2003
Resolved
Vessel does not have an Oil Record Book. LEGACY COMPONENT DESC: Oil Record Book
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 26 January 2004
Documentation › Logs/Records
Issued 13 August 2003
Resolved
Vessel does not have a Garbage Log. LEGACY COMPONENT DESC: Garbage Recordkeeping
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 15 January 2004
Pollution Prevention/Response › Prevention Equipment
Issued 13 August 2003
Resolved
The vessels Oil Water Seperator is inoperable. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 15 January 2004
Pollution Prevention/Response › Prevention Equipment
Issued 13 August 2003
No resolution recorded
Vessel does not have a Standard Discharge Connection. LEGACY COMPONENT DESC: Standard Discharge Connection
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 13 August 2003
Resolved
Vessel needs 2 additional B-II fire extinguishers for a total of 8. (Agent informed MSD AS that [name withheld] cleared deficiencies, however, there is no record of the DEF Check. Vessel departed, unable to verify.). LEGACY COMPONENT DESC: Number
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2004
Fire Fighting › Semiportable CO2 Fire Extinguishers
Issued 13 August 2003
Resolved
Vessel needs 1 B-III fire extinguisher for engineroom. (Agent informed MSD AS that [name withheld] cleared deficiencies, however, there is no record of the DEF Check. Vessel departed, unable to verify.). LEGACY COMPONENT DESC: Number
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2004
Pollution Prevention/Response › Prevention Equipment
Issued 13 August 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2004
Pollution Prevention/Response › Prevention Equipment
Issued 13 August 2003
Resolved
Vessel does not have fixed containment for all fuel / lube oil vents and fill pipes. LEGACY COMPONENT DESC: Fixed Containment
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 15 January 2004
Documentation › Certificates/Documents
Issued 13 August 2003
Resolved
Vessel does not have original COFR onboard. LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 15 January 2004