Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)76.4 ft × 18.0 ft × 8.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN TRACY & SONS INC · GLOUCESTER CITY, NJ, UNITED STATES · built 1947
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 18 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton 99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 22 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 22
5 November 2025Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8241235
1 July 2025Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8099672
18 October 2024Annual Inspection · Plan Review "T" Boat · Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7997807
8 September 2023COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7739924
7 August 2023Liferaft Servicing
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7803697
27 June 2023Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7677580
8 November 2022Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7568899
29 November 2021Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7348125
22 June 2021Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7233103
17 June 2021In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7228607
23 March 2021Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7161360
4 February 2021Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7135951
15 December 2019Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6874634
15 December 2019Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6881182
9 December 2019Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6859355
13 November 2019In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6855117
2 July 2019Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6725214
8 August 2018Administrative Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6515281
29 November 2017Administrative Inspection
Administrative · Navigation Center · Activity 6314614
20 June 2017Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6176154
10 May 2017Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6137495
9 August 2016Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5967336
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2025Resolved
All machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. MI found fuel oil leak on secondary fuel filter on port side MDE.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2025
Resolved 17 November 2025
Resolution: Vessel repaired leak on port engine.
Licenses other than ship stations in maritime services will normally be issued for a term of ten years. MI found FCC Station License expired and in the process of renewal.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2025
Resolved 2 December 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2025Resolved
Conduct satisfactory sea-trial prior to credit dry-dock.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 July 2025
Resolved 3 July 2025
Resolution: Conducted satisfactory sea-trial
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel was overdue for Annual Inspection on 13DEC2020. Vessel must complete satisfactory Annual Inspection prior to the carriage of passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2021
Resolution: Sector LA-LB personnel completed annual inspection of the small passenger MAURETANIA.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 December 2019Resolved
Vessel on which a pre-engineered fire extinguishing system is installed must have a means to reset devices used to automatically shut down ventilation and engines. Main engine overrides on seafire system not functional. Prove proper operation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2019
Resolution: Vessel proved proper operation of engine shutdown overrides on fixed fire system in engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 December 2019Resolved
Exposed hazards such as gears and rotating machinery must be properly protected by a cover, guard, or rail. Rotating machinery on stbd generator exposed. Provide adequate protection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2019
Resolved 11 December 2019
Resolution: Vessel provided adequate machinery guard for stbd generator.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 December 2019Resolved
A power driven vessel underway shall exhibit a masthead light forward. Vessels masthead light not functional. Prove proper installation and functionality of ul approved masthead light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2019
Resolved 11 December 2019
Resolution: Vessel installed new UL 1107 approved masthead light.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 July 2019Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel exceeded two year interval on 01JUL2019. Vessel required to undergo satisfactory drydock examination prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2019
Resolved 13 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2019Resolved
Old T-L must have 2 fixed power bilge pumps. Vessel has 02 Electric Pumps and 02 Generators. However, the Port generator is inoperable. Prove proper operation of the Port Generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2019
Resolved 13 November 2019
Conduct annual inspection. Vessel must undergo an annual inspection within the 3 months before or after each anniversary date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2018
Resolved 12 September 2018
Resolution: Annual COI conducted.
Construction/Loadline › Hull › Keel
Issued 20 June 2017Resolved
Grind to good wood and make available areas as identified #1,3,4,5,6.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 21 June 2017
Resolution: Yard made areas available for inspection.
Construction/Loadline › Hull › Keel
Issued 20 June 2017Resolved
Scarf to good wood area as identified #2 for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 21 June 2017
Resolution: Yard removed area identified and scarfed in a new piece of wood.
Construction/Loadline › Hull › Hull Plating
Issued 20 June 2017Resolved
Recaulk all areas as identified #1,2,3,4,5,6.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 21 June 2017
Resolution: Yard recaulked all areas identified.
Construction/Loadline › Hull › Hull Plating
Issued 20 June 2017Resolved
work list item: replace/Renew stbd aft anode for cathod system.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 23 June 2017
Resolution: Vessel installed anode for cathod system.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 May 2017Resolved
Demonstrate proper operation of pre-engineered fixed gas fire extinguishing system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2017
Resolved 17 May 2017
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 May 2017Resolved
Prove proper operation of fixed gas firefighting system shut down for generators drawing intake from the engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 12 September 2018
Resolution: Verifed installation of modification to SSDGs intake drawn from outside source and proprt operation in Fireboy system.
Fire Fighting › Grease Extraction Hood › General
Issued 10 May 2017Resolved
Repair disconnected fusible link for the galley hood fixed fire system.
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 10 May 2017
Resolution: Corrected during inspection.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.