KEN RYU

Built
2002
Last inspected
23 September 2020
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 September 2020
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2017–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9246293
642313
Flag
PANAMA
Maury page id
psix-642313

Documentation record

Tonnage as PSIX records it19707 - Convention (Subpart B), Gross Ton
10825 - Convention (Subpart B), Net Ton
31949 - Dead Weight, Ton
39034 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 5 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

23 September 2020 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7063527
26 August 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7033662
22 May 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6142298
14 May 2017 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6145941
14 May 2017 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6146090

Deficiency record · 7

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 August 2020 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO's identified active fuel oil leaks from the fuel oil leak alarm reservoirs on both generators number 1 and 2 creating a fire hazard and bringing their operability into question. 17ac 74 SOLAS (04) II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: Received, reviewed, and accepted class report. Crew renewed the packing for the drain pipe connectionand replaced the fuel injection pipe for the fuel injection valve.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 26 August 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all its respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO identified wasted door frame and missing insulating material on incinerator. 17ac 74 SOLAS (14) I/11.a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2020
Resolution: Received, reviewed, and accepted class report. Crew reparied the bent door frame with replacement of steel plate, renewed door seal and placed insulation materials for door cover.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 August 2020 Resolved
After any survey of the ship under Article 14 has been completed, no change shall be made in the structure, equipment, arrangements, material or scantlings covered by the survey, without the sanction of the Administration. PSCO identified temporary repairs to hatch cover jack support on the number 3 cargo hold without class approval. 50ac ICLL 66/Article 15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2020
Resolved 23 September 2020
Resolution: Repairs were found unsatisfactory, class issued condition for the No.3 cargo hatch cover to be permanetly repaired by the next docking survey.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 August 2020 Resolved
The construction and the means for securing the weathertightness of cargo and other hatchways in positions 1 and 2 shall be at least equivelant to the requirements of regulations 15 and 16 of this Annex.PSCO identified cargo hatch covers with tape over holes which were missing 11 bolts on all five cargo holds. 50ac ICLL 66/14.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2020
Resolved 23 September 2020
Resolution: Gas sampling holes were found correct with new supply of plugs for missing ones.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2020 Resolved
After any survey of the ship under regulation 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by this survey without the sanction of the Administration. PSCO identified temporary hoses running from sewage treatment plant to ballast tank. Alterations to sewage piping were not approved by class. 50ac 74 SOLAS (14) I/11.b
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2020
Resolved 23 September 2020
Resolution: Temporary hoses were replaced with piping and ship owner has been advised that any alteration to sewage piping must be approved by class in the future.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 22 May 2017 Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The identified equipment in ship's SMS is missing the required spare equipment needed to prevent a hazardous situation as per ship's document number SMP-16-01B. ISM Code Part A 10.3 Action: 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 August 2020
Resolution: PSCO conducted routine PSC B exam. Crew aquired spare equipment.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 22 May 2017 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirement which may be established by the company. The vessel does not have written maintenance procedure intervals established for machinery equipment. Currently, there is no maintenance history. ISM Code Part A 10.1 Act:10
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 May 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.