AGATHONISSOS is a 2002 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in March 2020, along with 3 deficiencies and 2 operational controls.

Records from 2016 to 2020. Most recent: inspection, 30 March 2020.

Built
2002
Last inspected
30 March 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 March 2020
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9232448
643254
Flag
GREECE
Maury page id
psix-643254

Documentation record

Tonnage as PSIX records it57062 - Convention (Subpart B), Gross Ton
32824 - Convention (Subpart B), Net Ton
122954 - Displacement, Ton
106149 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

30 March 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6933199
30 December 2019 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6879765
21 May 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6689907
30 July 2018 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6492222
27 August 2017 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6252588
8 August 2017 COE-Dockside · COE-Administrative
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6228151
10 July 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Annual · COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6203994
6 July 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6199580
23 March 2017 COE-Dockside · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6110361
9 November 2016 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6038140
15 October 2016 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6022865
16 August 2016 COC-TVE Renew · Ballast Water Examination · COE-Dockside · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5974239
11 August 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5969468
25 April 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5862235

Deficiency record · 3

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 30 December 2019 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. VOM-OSPO19 pumproom entry procedure ventilation is started at least (1) hour prior to the programmable entry and during the works. As denoted in deficiency #2, the cargo pump room #2 fan was wired improperly during vsl visit to Freeport, Bahamas on 11/28/2019. As such, the pump room was supplied with positive as opposed to negative {suction type} causing a hazardous condition. Pump room was entered multiple times by the vessels crew since the last service. {74 SOLAS 14 IX/3.1} {Ref ISM Code 10.1}
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2020
Resolved 30 March 2020
Resolution: Internal audit report was submitted addressing the concerns and issues identified in deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 December 2019 Resolved
Cargo pump rooms shall be mechanically ventilated and discharges from the exhaust fans shall be led to a safe place on the open deck. The ventilation shall be of the suction type using fans of the non-sparking type. #2 Pump room exhaust fan was wired backwards causing the pump room space to be positivley ventilated as opposed to the required suction type. Electrician swapped the wiring allowing the ventilation fan to spin in the direction necessary to provide negative (suction type) ventilation. An additional internal verification of the vessel's SMS focusing on maintenance of the ship and cargo pump room entry procedures is required in three months. 74 SOLAS (01) II/2.59.3.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 December 2019
Resolved 30 December 2019
Resolution: Electrician swapped the wiring allowing the ventilation fan to spin in the direction necessary to provide negative (suction type) ventilation.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 July 2018 Resolved
The high level alarm must... activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled. The audible alarm volume is so low that it cannot be readily heard by the watchstander in the cargo control room. 46 CFR 39.2007 50 a/c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 August 2018
Resolved 14 August 2018
Resolution: See attached class report.