MAURY USCG vessel records Sign in
← All vessels

TK ROTTERDAM

TK ROTTERDAM is a 2001 freight ship. The Coast Guard has recorded 3 inspections since 2003, most recently in March 2004, along with 7 deficiencies.

Records from 2003 to 2004. Most recent: inspection, 19 March 2004.

Built
2001
Last inspected
19 March 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9045613 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
643295
Flag
MALTA
—
Maury page id
psix-643295

Inspections, by type

Years with a record 2 calendar years (2003–2004)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8749 - Dead Weight, Ton
12300 - Displacement, Ton
6036 - Convention (Subpart B), Gross Ton
3522 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

19 March 2004 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2027310
5 March 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2018965
11 August 2003 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1897600

Deficiency record · 7

Fire Fighting › Firemans Outfit
Issued 5 March 2004 Resolved
The reflective layer on both fireman's outfits is worn and outfits are in need of replacement. Replace with suitable outfits. LEGACY COMPONENT DESC: Protective Clothing
Action required: 705 - Other - as specified
Due 7 March 2004
Resolved 16 March 2004
Resolution: Received faxed copy of invoice from vessel''''''''s agent showing that 02 fireman''''''''s oufits had been purchased.
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 September 2003 Resolved
Radar - Improper/Lack of Maintenance
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2003
Navigation › Piloting/Steering › Gyro Compass
Issued 5 September 2003 Resolved
Gyro Compass - Improper/Lack of Maintenance
Condition: Improper/Lack of Maintenance
Due 15 September 2003
Resolved 15 September 2003
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 5 September 2003 Resolved
BUCKETS OF OIL IN ENGINE ROOM TO BE REMOVED
Condition: Improper/Lack of Maintenance
Due 5 September 2003
Resolved 5 September 2003
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 5 September 2003 Resolved
OIL ON DECK, PORT SIDE AFT TO BE WIPED UP
Condition: Improper/Lack of Maintenance
Due 5 September 2003
Resolved 5 September 2003
Communications › Alarms/Indicators
Issued 5 September 2003 Resolved
ALARMS AND CONTROLS IN ENGINE CONTROL ROOM TO BE OPERATIONAL
Condition: Improper/Lack of Maintenance
Due 5 September 2003
Resolved 5 September 2003
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 August 2003 Resolved
Oily Water Separator (15 ppm) - Improper/Lack of Maintenance
Condition: Improper/Lack of Maintenance
Due 15 September 2003
Resolved 15 September 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.