PANDA is a 1969 freight ship. The Coast Guard has recorded 53 inspections since 2003, most recently in October 2008, along with 65 deficiencies and 31 operational controls.

Records from 2003 to 2008. Most recent: operational control imposed, 27 October 2008.

Built
1969
Last inspected
27 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7000229 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
643297
Flag
COOK ISLANDS
—
Maury page id
psix-643297

Inspections, by type

…with no type recorded45
Years with a record 6 calendar years (2003–2008)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it299 - Regulatory (Subpart C or D), Gross Ton
525 - Convention (Subpart B), Gross Ton
231 - Regulatory (Subpart C or D), Net Ton
231 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 53

27 October 2008 Ballast Water Examination · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3352005
16 October 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3348103
10 October 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3342355
16 May 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3208376
7 May 2008 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 3201005
6 May 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3200069
13 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3163617
9 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3161039
25 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3161516
14 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3130822
13 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3129580
9 November 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3095371
8 November 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3095514
11 September 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 3055562
21 June 2007 PII Safety Exam · Deficiency Check · ISPS II Exam · ISM Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2938869
23 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2937933
10 October 2006 ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2797021
6 April 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2618416
17 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2604415
28 February 2006 PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS II Exam · ILO-147 Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2593122
12 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2512849
8 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2510552
19 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2496166
22 August 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2472667
20 August 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2468880
10 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2421515
6 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2381859
4 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2378741
1 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2347083
29 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2322617
28 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2300490
25 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2299549
28 January 2005 PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2276236
18 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2276292
14 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2275047
11 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2273175
9 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2256187
4 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2253357
28 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2231090
26 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2229089
1 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2211183
29 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2208297
5 August 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2157205
27 July 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2146677
27 July 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2153161
25 July 2004 Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2143906
29 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2082050
29 April 2004 Type not recorded
No type recorded · USCGC THETIS (WMEC 910) · Activity 2089237
13 April 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2044296
30 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2033989
29 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2033722
18 December 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1965922
18 August 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1879640

Deficiency record · 65

Lifesaving › Rescue Boat › Construction
Issued 13 November 2008 Resolved
Connection on rescue boat to cable parted while conducting drill.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2008
Resolution: Connection to rescue boat was purchased and installed. Inspected by PSCO.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 November 2008 Resolved
Vessel recieved worklist of 19 non-conformities from ISM auditer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2008
Resolution: List of non-conformites has been completed to the satisfaction of Flag and PSCOs.
Lifesaving › Hand Flares › Expired
Issued 27 October 2008 Resolved
Flares and Line Throwing Devices expired. Provide replacements prior to departure. 03NOV: New flares purchased. Pyro-launcher for Line-throwing Device missing. Orange smoke signals (2) expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2008
Resolution: New flares and line-throwing devices have been purchased and installed on ship.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 27 October 2008 Resolved
ISM-DOC not endorsed. Provide endorsement prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Personnel › Certificates/Documents/Licenses › License, Master
Issued 27 October 2008 Resolved
Master does not have valid flag state endorsement. Provide endorsement prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 27 October 2008 Resolved
Vessel not incompliance with safe manning certificate. Provide first mate prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Communications › Radio Communications › EPIRB
Issued 27 October 2008 Resolved
EPIRB expired. Provide replacement prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 27 October 2008 Resolved
Hydrostatic release for both liferafts expired. Provide replacement prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Lifesaving › Visual Distress Signals (General) › Expired
Issued 27 October 2008 Resolved
SART Expired. Provide replacement prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Engineering › Fuel Oil Service System › Piping
Issued 29 May 2007 Resolved
Emergency generator fuel line severely wasted. Line from aft fuel tank along main deck to forward compartment had 12 inch rubber soft patch. Condition is such that, if PSCO were to tap it with inspection hammer, it would cause a major leak.
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 20 June 2007
Resolution: Emergency generator line replaced.
Fire Fighting › Fire Main › Condition
Issued 29 May 2007 Resolved
PSCO observed entire fire main severely wasted with holes and rust. Piping had several large holes over a 12 inch section. Water was spraying out through holes with significant pressure. Pressure at nozzle was not maintained, water was trickling out of nozzle. Vessel could not adequately fight fire with the fire main leaks.
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 4 June 2007
Resolution: Fire Main was adequately repaired and satisfactory operation observed
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 29 May 2007 Resolved
Emergency fire pump did not start. PSCO's observed crew member pull on starting cord for 10 minutes. As he pulled, it parted, resulting in the pump not having a means of starting. Pump is not operational.
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 4 June 2007
Resolution: Vessel installed new emergency fire pump. Satisfactory operation was observed.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 29 May 2007 Resolved
Vessel does not have the chief engineer. Vessel does not meet the minimum safe manning certificate. Previous chief engineer signed-off vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2007
Resolved 21 June 2007
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 29 May 2007 Resolved
Company (ISM) failed to provide evidence of reviewing non-conformities and taking corrective action on several major safety items. PSCO's observed non-conformity log with damaged fire pipe line noted march 03, 2007; in which no action was taken. Vessel made two voyages on 3/28/07 and 5/15/07 with this major non-conformity.
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 21 June 2007
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 29 May 2007 Resolved
CCSSC requires vessels to have 2 anchors. Vessel missing starboard anchor.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2007
Resolved 20 June 2007
Resolution: Vessel installed starboard anchor.
Deck/Cargo › Mooring/Anchoring › Anchor Cable
Issued 29 May 2007 Resolved
Port side anchor chain severely rusted and wasted. Condition is such that, it is at risk of parting during normal operations.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2007
Resolved 20 June 2007
Resolution: Vessel installed new anchor chain.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 May 2007 Resolved
VHF radio microphone "push-to-talk" button does not have conductivity. Button does not complete the circuit. Vessel does not have means of VHF radio.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2007
Resolved 20 June 2007
Resolution: Vessel installed new microphone.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 29 May 2007 Resolved
Antenna for GPS broken; signal not captured.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2007
Resolved 20 June 2007
Resolution: Vessel installed new GPA antenna.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 29 May 2007 Resolved
Based on the deficiencies found on the fire main, and the company did not take action on this major non-conformity, of which is critical to the ship's operation, PSCO's believe the SMS is not being implemented. Vessel made two voyages on 3/28/07, and 5/15/07 with major critical non-conformity required to be repaired prior to sailing. Recommend Flag Administration audit of SMS.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2007
Resolved 21 June 2007
Electrical › Electric Generation Source (emergency) › Switch
Issued 26 October 2006 Resolved
Emergency Shut-off valve was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2006
Resolved 10 November 2006
Resolution: Flag faxed letter attesting to repairs. Vsl released from Custom''s Hold.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 October 2006 Resolved
Flag endorsement for Master expires on 27 OCT 06. Must provide application or new endorsement prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2006
Resolved 26 October 2006
Resolution: Received flag endorsement for Master
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 23 October 2006 Resolved
Found open extention cords used to provide electricity to on-deck refrigerators. Must hard-wire unit or remove
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2006
Resolved 26 October 2006
Resolution: Vsl hardwired on-deck refrigerators.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 23 October 2006 Resolved
Main switchboard did not have non-conductive matting
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 October 2006
Resolved 26 October 2006
Resolution: Installed non-conductive matting
Fire Fighting › Fire Pumps › Arrangement
Issued 23 October 2006 Resolved
Main firepump was inoperable
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2006
Resolved 26 October 2006
Resolution: found that valves were mis-aligned. Corrected.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 23 October 2006 Resolved
Rescue Boat engine did not start
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2006
Resolved 26 October 2006
Resolution: operational
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 23 October 2006 Resolved
Did not have a portable fire estinguisher in the rudder room.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2006
Resolved 26 October 2006
Resolution: installed
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 10 October 2006 Resolved
CCSSC CERTIFICATE HAS NOT HAD REQUIRED ANNUAL SURVEY AND IS PAST THE 3 MONTH EXTENSION. CERTIFICATE IS INVALID
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2006
Resolved 23 October 2006
Resolution: Validated newly issued CCSSC
Documentation › Certificates/Documents › International Load Line Certificate
Issued 10 October 2006 Resolved
ILLC CERTIFICATE HAS NOT HAD REQUIRED ANNUAL SURVEY AND IS PAST THE 3 MONTH EXTENSION. CERTIFICATE IS INVALID
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2006
Resolved 23 October 2006
Resolution: Annual Survey has been conducted.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 10 October 2006 Resolved
ISM DOC COPY OF ANNUAL SURVEY ENDORSEMENT IS NOT ABOARD SHIP
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2006
Resolved 23 October 2006
Resolution: Annual Endorsement has been conducted.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 28 February 2006 Resolved
Submit ballast water management plant to NBIC. Reports are required onboard prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2006
Personnel › Certificates/Documents/Licenses › License, Master
Issued 28 February 2006 Resolved
Master to provide proof of application acceptance from flag administration for STCW documents. Prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 February 2006 Resolved
Vessel to install or demonstrate proper operation of emergency lighting.
Action required: 705 - Other - as specified
Resolved 16 March 2006
Communications › Audible Communications › Horn/Whistle
Issued 28 February 2006 Resolved
Demonstrate proper operation of ship’s whistle while on main generator and emergency power
Action required: 705 - Other - as specified
Resolved 16 March 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 28 February 2006 Resolved
Repair hose on large CO2 extinguisher in engine room and provide servicing/inspection report from approved facility.
Action required: 705 - Other - as specified
Resolved 16 March 2006
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 28 February 2006 Resolved
Provide and demonstrate proper operation of ship's emergency fire pump.
Action required: 705 - Other - as specified
Resolved 28 February 2006
Deck/Cargo › Cargo Stowage › General
Issued 19 September 2005 Resolved
Stowage of cargo deck is overloaded. View from pilot house restricted, access to bow is restricted. Cargo will be reloaded according to vessel cargo plan, after the storm passes and the port is cleared by the COTP.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2005
Lifesaving › Lifeboat › Propulsion Engine
Issued 28 January 2005 Resolved
Rescue boat motor inoperable. Make proper repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2005
Resolution: Replaced Engine
Lifesaving › Visual Distress Signals (General) › Expired
Issued 28 January 2005 Resolved
Smoke signals from pilothouse were found expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 January 2005 Resolved
Generator and ballast pump missing protective guards on moving parts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 January 2005 Resolved
Update fire control plan to meet the vessels current configuration. Remove halon markings from plan.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2005
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 January 2005 Resolved
Prove proper opeation of smoke detection and alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 27 July 2004 Resolved
Vessel does not have a chief mate on board. Provide a chief mate with proper STCW certificates and lisence in accordance with minimum safe manning. CCSSC 1.7 74 SOLAS 74/78, 5/13 STCW95 1/2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2004
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 27 July 2004 Resolved
Vessel must present original ships certificates in the presence of a US coast guard inspector. 74 SOLAS I/16
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2004
Operations/Management › Drills/Instruction › Fire
Issued 27 July 2004 Resolved
Vessel requires to have full crew ready for a priority II AEF, conducted by USCG
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2004
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 27 July 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2004
Engineering › Reduction Gearing/Clutches › Gear, Jacking
Issued 27 July 2004 Resolved
Main reduction gear cooler end bell (plate) holed and wasted. Remove old end bell and install new end bell on aft end of cooler, prior to departure from port and to the satisfaction of the flag administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 July 2004 Resolved
Port side salt water suction pipe from aft bulkhead in engine room to suction valve and engine strainers is wasted and holed. Remove all bad piping and properly install new piping, to the satisfactory of the flag state. Prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 July 2004 Resolved
Starboard side saltwater suction pipe from sea suction valve to main engine strainers are wasted and holed. Remove old bad pipe and properly install new pipe to the satisfaction of the flag administration. Prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 August 2004
Lifesaving › Visual Distress Signals (General)
Issued 18 August 2003 Resolved
Vessel does not have required number of pyrotechnics. LEGACY COMPONENT DESC: Quantity
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Lifesaving › Line-Throwing Appliances
Issued 18 August 2003 Resolved
Vessel does not have line-throwing appliances onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Resolution: Vessel is now CCSSC and does not require these.
Lifesaving › Rescue Boat
Issued 18 August 2003 Resolved
Vessel does not have a rescue boat installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Lifesaving › Launching Appliances
Issued 18 August 2003 Resolved
Motorized davit for rescue boat not provided onboard. LEGACY COMPONENT DESC: Davit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Electrical › Electric Generation Source (emergency)
Issued 18 August 2003 Resolved
Emergency batteries need to be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Lifesaving › Inflatable Liferafts
Issued 18 August 2003 Resolved
Liferafts are overdue for servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 18 August 2003 Resolved
The fixed halon fire-fighting system for the engine room is overdue for testing and hydro-test.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Resolution: Halon system was removed and was replaced with a large semi-portable CO2 bottle.
Operations/Management › Drills/Instruction
Issued 18 August 2003 Resolved
No SOLAS training manual. LEGACY COMPONENT DESC: Safety Orientation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Electrical › Lighting (service)
Issued 18 August 2003 Resolved
Several lights in the engine room are missing covers. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Pollution Prevention/Response › Prevention Equipment
Issued 18 August 2003 Resolved
Permanent repairs to a hole in the sewage tank are required.. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Electrical › Electric Supply System (service)
Issued 18 August 2003 Resolved
For all battery chargers, provide permanent electircal connections. LEGACY COMPONENT DESC: Battery Charger
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Electrical › Electrical Distribution System (service)
Issued 18 August 2003 Resolved
Electrical wiring in the engine room needs proper terminating points or junction boxes. LEGACY COMPONENT DESC: Junction Box
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 18 August 2003 Resolved
Exhaust leak from the generator located in the forecastle needs repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 18 August 2003 Resolved
Repair elbow in exhaust line for generator in forecastle and install proper insulation material.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Construction/Loadline › Markings
Issued 18 August 2003 Resolved
Current loadline does not reflect markings on loadline certificate. LEGACY COMPONENT DESC: Load Line Mark
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2003
Fire Fighting › Fire Pumps
Issued 18 August 2003 Resolved
Currently, the emergency fire pump is gasoline. Provide a diesel pump and test in presence of USCG inspector. LEGACY COMPONENT DESC: Arrangement
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2003
Lifesaving › Launching Appliances
Issued 18 August 2003 Resolved
Rescue Boat cannot effectively swing over the side to be properly lowered. Provide an efficient means to swing the rescue boat while attached to the davit. LEGACY COMPONENT DESC: Davit
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2003
Resolution: Witnessed satisfactory operational test of rescue boat and davit.

Ownership record