← All vessels
SOUTH FLORIDA PRINCESS
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named SOUTH FLORIDA PRINCESS
SOUTH FLORIDA PRINCESS is a 2003 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2003, most recently in February 2026, along with 49 deficiencies and 1 operational control.
Records from 2003 to 2026. Most recent: inspection, 10 February 2026.
- Built
- 2003
- Last inspected
- 10 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 49 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1146233
WDM6766
643388
Flag
UNITED STATES
368228110
Maury page id
psix-643388
Inspections, by type
The 38 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)73.5 ft × 20.0 ft × 5.5 ft
Registered tonnagegross 61 / net 41
ITC dimensions (L × B × D)73.5 ft × 20.0 ft × 5.5 ft
ITC tonnageNot recorded
BuilderTSS FABRICATING INC · LA CROSSE, WI, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOLLYWOOD, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 21 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM6766MMSI 368228110 · active · compulsorily equipped · granted 18 November 2021, expires 18 November 2031
WDE5448MMSI 367366860 · expired · compulsorily equipped · granted 4 July 2008, cancelled 8 September 2018 · licensed under a name not among this hull’s recorded names (not shown)
WDB9537MMSI 366978040 · expired · compulsorily equipped · granted 16 September 2004, cancelled 22 November 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 38
10 February 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8308494
11 February 2025
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8077791
12 August 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7979390
11 July 2024
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7956109
8 February 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7862772
14 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7636368
3 August 2022
Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7524543
15 November 2021
Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7351163
10 February 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7137559
11 August 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7030167
6 February 2020
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6903264
17 January 2019
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6611538
8 August 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6498540
20 February 2018
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6358628
17 November 2016
COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6041295
19 September 2016
In-Service Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6004366
15 September 2016
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6001358
14 March 2016
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5833113
5 October 2015
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5735492
16 July 2012
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4376242
13 September 2011
Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4145688
8 August 2011
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4109741
26 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3880576
7 July 2009
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3527196
26 March 2009
Drydock Exam
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 3447946
5 December 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3374816
10 June 2008
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3225470
20 March 2008
Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3168756
10 October 2007
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3072556
5 October 2006
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2794195
11 September 2006
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2774572
2 March 2006
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2594577
12 September 2005
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2493346
9 August 2005
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2456543
5 October 2004
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2214155
9 August 2004
COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2183129
16 September 2003
Deficiency Check · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1905351
21 February 2003
Construction Oversight · Hull Examination
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1880810
Deficiency record · 49
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 August 2024
Resolved
No vessel which is required by § 67.7 to be documented may engage in unlimited coastwise trade or the fisheries without being documented in accordance with the requirements of this part.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2021
Resolved
Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20. The auxiliary diesel generator exhaust pipe is broken at the first weld inboard from the port engine room side shell. Make permanent repairs.
46 CFR 182.20-15
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2021
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Remove all interior "rope" lights installed on the vessel or provide proof that they meet the marine service specification.
46 CFR 183.10-20
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 November 2021
Resolved
Each hot water heating boiler must have at least one safety relief valve. Found the fwd water heater safety relief valve to be leaking while secured. Replace safety relief valve prior to use.
46 CFR 53.05-2
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 November 2021
Resolved
Stations in the maritime service must be licensed by the FCC. Provide valid FCC Station License.
47 CFR 80.13
Communications › Radio Communications › EPIRB
Issued 22 February 2018
Resolved
Each disposable hydro release unit must be marked with an expiration date. 46 CFR 185.740(b)
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 22 February 2018
Resolved
Fixed gas fire extinguishing system must automatically shut down all engines. Provide tech report that shutdowns are operational. 46 CFR 181.420
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 February 2018
Resolved
Vessel must undergo satisfactory USCG annual inspection prior to carriage of passengers.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 October 2015
Resolved
Alcohol test strips were expired. Obtain at least three test strips that are not expired.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 October 2015
Resolved
The overhead insulation, in various areas, in the engine room is hanging which would expose the overhead to heat if there were a fire. Re-attach insulation to protect overhead.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 8 August 2011
Resolved
A device must be provided to automatically shut down power ventilation servicing a CO2 protected space (engine room) and to automatically shut down engines that draw intake air from the protected space (fan & back-up gen set do not shutdown when pressure switch is activated). 46 CFR 181.410(b)(10).
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 8 August 2011
Resolved
FCC safety certificate expired. 47 CFR 13
Personnel › Training › Ship's Business
Issued 8 August 2011
Resolved
FCC radio operator permit not available. 47 CFR 13
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 August 2011
Resolved
Provide current CG light list and coast pilot. 46 CFR 184.420
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 7 July 2009
Resolved
Provide a proper FCC Great Lakes Agreement Radio Safety Inspection Certificate IAW 46 CFR 184.502 and 47 CFR 80.59 (b). Currently the vessel has not had the required radio safety inspection completed.
Documentation › Logs/Records › Logbook (official)
Issued 7 July 2009
Resolved
Provide proper logged Crew training IAW 46 CFR 185.524. Currently not all members in the crew have proper documentation to confirm adequate training.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 March 2009
Resolved
Mark life jacket storage containers with 2 inch letters and numbers IAW 46 CFR 185.604 (f).
Engineering › Bilge Water Management System › Piping
Issued 26 March 2009
Resolved
Replace corroded length of stbd bilge discharge pip IAW 46 CFR 182.510 (b) and 46 CFR 182.710 (c) (1).
Engineering › Steering Gear System › Rudder Bearing
Issued 26 March 2009
Resolved
Replace stbd rudder shaft cutlass bearing IAW 46 CFR 61.20-23 (b).
Engineering › Lubricating Oil Service System › Hose
Issued 10 June 2008
Resolved
Provide proper oil hose that meets SAE J-1942 requirements on aft generator turbo drain hose. 46 CFR 182.720(e). As an alternative a fire sleeve can be installed over the current hose.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 10 June 2008
Resolved
Provide proper life jacket markings I.A.W. 46 CFR 185.604(b) (vessel name on jackets needs to be changed to new vessel).
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 June 2008
Resolved
Provide proper navigation lights I.A.W. 46 CFR 183.420 prior to operating at night or in reduced visibility. (STBD Nav light is inop.)
Communications › Radio Communications › VHF Radiotelephone
Issued 10 June 2008
Resolved
Provide proper Station License (correct vessel) and safety certificate as required by 46 CFR 184.502.
Lifesaving › Hand Flares › Expired
Issued 10 June 2008
Resolved
Provide Proper number and type of distress flares and smoke signals I.A.W. CFR 180.68(a).
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 10 June 2008
Resolved
Provide proper name on the port and stbd bow as required by 46 CFR 67.123(a) Prior to 7/10/08.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 10 June 2008
Resolved
Provide surfaces within 3 feet of the galley cook-top, convection oven, and upright ovens that meet ASTM E-84 standards as required by 46 CFR 177.410. No cooking is to be done when passengers are onboard the vessel.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 10 June 2008
Resolved
Provide Draft Marks/Loading Marks on the vesssel IAW 46 CFR 185.602 and the vessel's stability letter. *Due at Next Dry Dock of Vessel*
Lifesaving › Rescue Boat › Capacity
Issued 10 June 2008
Resolved
Provide Rescue Boat for vessel or install a camera system (as discussed with Master) to meet the requirements for a waiver. 46 CFR 180.210(a) (2).
Personnel › Training › Familiarization Training
Issued 10 June 2008
Resolved
Provide Proper Senior Deckhand Designation Letter with Documentation of Required Training I.A.W. NVIC 1-91 and 46 CFR 185.420 Prior to 24 June 08.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 September 2006
Resolved
SECURE RAILS
Documentation › Markings/Placards › Warning Signs
Issued 11 September 2006
Resolved
POST LIFE JACKET DONNING PLACARD
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 11 September 2006
Resolved
MARK BILGE ALARM BREAKER
Electrical › Electric Supply System (service) › Cable
Issued 11 September 2006
Resolved
HARD WIRE ELECTRICAL CABLE.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 12 September 2005
Resolved
PROVIDE PROCEDURES FOR SERIOUS MARINE INCIDENT AND EAP INFORMATION FOR CREW.
Communications › Radio Communications › EPIRB
Issued 12 September 2005
Resolved
PROVIDE A CURRENT HYDROSTATIC RELEASE FOR THE EPIRB.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 12 September 2005
Resolved
LOG THE MONTHLY LIFESAVING EQUIPMENT INSPECTION INCLUDING THE EPIRB TEST.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 September 2005
Resolved
PROVIDE 60 FEET OF BOUYANT NON-KINKING UV RESISTANT LINE FOR THE RING BOUY.
Documentation › Certificates/Documents › FCC SSL
Issued 9 August 2004
Resolved
Provide valid FCC Safety Certificate.
Documentation › Certificates/Documents › FCC SSL
Issued 9 August 2004
Resolved
Provide valid FCC Station License
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 9 August 2004
Resolved
Provide proof of payment for user fee.
Communications › Radio Communications › EPIRB
Issued 9 August 2004
Resolved
Provide NOAA registration for EPIRB.
Lifesaving › Hand Flares › Quantity
Issued 16 September 2003
Resolved
Provide an additional 2 hand red or hand orange emergency signals as per 46CFR180.68.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 September 2003
Resolved
Remove seat cushions on 2nd deck stern lifejacket locker and label "Not a Seat". ref. 46CFR177.820(b).
Deck/Cargo › Ballast
Issued 16 September 2003
Resolved
Install securing straps for the fixed ballast in the bow.
Documentation › Certificates/Documents
Issued 21 February 2003
Resolved
PROVIDE ORIGINAL ON BOARD VESSEL. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Documentation › Certificates/Documents
Issued 21 February 2003
Resolved
PROVIDE ORIGINAL LETTER ON BOARD VESSEL AND POST IT. LEGACY COMPONENT DESC: Stability Letter
Engineering › Generator (propulsion/auxiliary-electric)
Issued 21 February 2003
Resolved
AUX GENERATOR RUNNING AT 600 RPM OVER MANUFACTURES SPEC. AWAITING PARTS TO FIX LEGACY COMPONENT DESC: Fixture Circuitry
Engineering › Steering Gear System
Issued 21 February 2003
Resolved
NOT OPERATING AT BRIDGE. LEGACY COMPONENT DESC: Rudder Angle Indicator
Engineering › Diesel Engine (propulsion-direct drive)
Issued 21 February 2003
Resolved
GAUGES AT OPERATING STATION NOT OPERATIONG.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.