MAURY USCG vessel records Sign in
← All vessels

PINK CORAL

PINK CORAL is a 2003 tank ship. The Coast Guard has recorded 13 inspections since 2003, most recently in January 2016, along with 7 deficiencies and 7 operational controls, 1 with no removal date recorded.

Records from 2003 to 2016. Most recent: operational control imposed, 26 January 2016.

Built
2003
Last inspected
26 January 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9259898 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
643502
Flag
MALTA
—
Maury page id
psix-643502

Inspections, by type

…with no type recorded6
Years with a record 7 calendar years (2003–2016)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29982 - Convention (Subpart B), Gross Ton
12861 - Convention (Subpart B), Net Ton
49474 - Dead Weight, Ton
59326 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

26 January 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5803737
15 November 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3890044
15 November 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3891380
3 March 2009 MARPOL Annex V Examination · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex II Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3426738
3 March 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3427229
20 November 2007 NPV Safety Exam · Deficiency Check · ISPS III Exam · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3099383
14 November 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3096762
14 November 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3098839
29 June 2007 MARPOL Annex I Examination · COC-CHEM Renew · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2977465
28 June 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2976463
30 October 2005 COC-TVE Renew · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2524701
17 August 2004 PII Safety Exam · ISPS I Exam · COC-TVE Annual
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2168394
13 August 2003 Ballast Water Examination · Certificate of Compliance · Tank Vessel Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1874863

Deficiency record · 7

Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 20 November 2007 Resolved
The vessel was brought into the port in a hazardous condition with 03 of the cargo tanks laden with gasoline with an oxygen content above 13% oxygen. This is not in accordance with the Ships Cargo Handling Manual which states "inerected spaces must be maintained at not more than 6% oxygen" as stated in Chapter 7.
Due 20 November 2007
Resolved 20 November 2007
Resolution: Corrected on the spot.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 15 November 2007 Resolved
The vessel crew could not demonstrate the proficiency in operation of the inert gas system in that the cargo officer could not perform the tests of alarms & required shut downs in the presense of PSC. These alarms are required by the ship's SMS & Cargo Manual to be tested & documented monthly.
Action required: 705 - Other - as specified
Due 16 December 2007
Resolved 20 November 2007
Resolution: The crew properly demonstrated proficiency in the operation of the inert gas system.
Deck/Cargo › Cargo Stowage › General
Issued 15 November 2007 Resolved
The ship currently has only one portable oxygen meter that is documented as calibrated and properly maintained.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2007
Resolved 20 November 2007
Deck/Cargo › Cargo Stowage › General
Issued 15 November 2007 Resolved
Vessel was brought into the port in a hazardous condition with 3 of the cargo tanks laden with gasoline with an O2 content above 13%. This is not IAW the vessels SMS or Cargo Handling Manual which requires inerted tanks to be kept below 6% O2 at all times. Crew was directed to IG the cargo tanks to below 6% O2.
Action required: 705 - Other - as specified
Due 15 November 2007
Resolved 15 November 2007
Resolution: IGS was put on-line and all the cargo tanks were verified to be less then 6% O2
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 29 June 2007 Resolved
Ship to be provided with Cargo Record Book for ship carrying noxious liquid substance in bulk, which includes the updates which came into enforcement 01JAN07, prior to loading Annex II Cargos.
Action required: 705 - Other - as specified
Resolved 21 August 2007
Resolution: Received confirmation that Cargo Record book has been placed onboard.
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 17 August 2004 Resolved
Prior to cargo operations, class must attest to the proper operation of all audible and visual alarms related to the inert gas system. SOLAS 74 II/19.1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2004
Resolution: [name withheld] reports in company cover letter def is corrected.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 17 August 2004 Resolved
Prior to loading cargo in the U.S., the vessel must prove proper operation of the visual high level alarm on the bridge open deck to the satisfaction of the U.S. Coast Guard. 46 CFR 153.409
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 August 2004
Resolution: Captain reports on company letter def is corrected.

Ownership record