Records from 2003 to 2023. Most recent: inspection, 11 December 2023.
Inspection history · 37
11 December 2023
PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7833744
24 May 2022
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7458410
24 May 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7470268
9 March 2022
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7407969
8 March 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7407818
27 December 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7372796
3 November 2021
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7344634
8 October 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329374
31 August 2021
PSC B · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7294527
10 January 2018
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6331739
6 March 2017
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6099371
27 January 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5804883
20 January 2016
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5800323
15 May 2014
COE-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4851233
10 September 2011
COC-TVE Renew · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4125069
22 March 2010
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3696975
25 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3685951
8 January 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3661132
30 December 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3656577
1 December 2009
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3634781
23 March 2009
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3438345
21 March 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3437578
4 February 2009
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3412072
14 April 2008
COC-TVE Annual · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3182606
20 April 2007
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2914767
26 September 2006
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2787467
24 September 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2785805
10 January 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2564299
14 October 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2514901
20 September 2005
COC-TVE Renew · ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2497270
11 May 2005
Spot Check · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2355061
19 April 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2338267
22 March 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2317374
17 September 2004
COC-TVE Annual · ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2198488
21 August 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1882842
20 August 2003
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1879731
19 August 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1881082
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 May 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed 5 foot by 3 foot puncture in Bosun Storage, Frame 111. Require damage assessment to include all adjacent compartments, tanks, and bulbous area for damage.
74SOLAS (20) I/11(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 25 May 2022
Resolved 15 June 2022
Resolution: Received, reviewed and approved class report from LR verifing vessel's repairs were completed and approved by approved technician and Class.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 9 March 2022
Resolved
EVERY STEAM PIPE AND EVERY FITTING CONNECTED THERETO THROUGH WHICH STEAM MAY PASS SHALL BE SO DESIGNED, CONSTRUCTED AND INSTALLED AS TO WITHSTAND THE MAXIMUM WORKING STRESSES TO WHICH IT MAY BE SUBJECTED. PSCO OBSERVED LEAKS ON STEAMLINES LOCATED NEAR TANKS ONE PORT AND SIX STARBOARD. 74 SOLAS(04) II-1/33.1 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 March 2022
Resolution: Steam heating pipe for cargo tank No.1P and No.6S were cropped and renewed. Three valves were replaced w/ new spares. Steam heating pipes has been renewed, installed and tested successfully.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 November 2021
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL REPORTED PARTIAL LOSS OF PROPULSION WHILE TRANSITING DELAWARE BAY. VESSEL MUST PROVIDE A CLASS REPORT WITH A CAUSAL ANALYSIS OF THE LOSS OF PROPULSION AND COMPLETION OF REPAIRS PRIOR TO MOVEMENT.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 November 2021
Resolution: Received Class report;the issue was traced to the air in the fuel oil (fo)counter meter.Once the counter meter was bypassed and the fo line was purged,the fo pressure returned to normal (8 bar).
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 31 August 2021
Resolved
Safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops to prevent overstressing the fall or davits. While retrieving the starboard side life boat, the first activation of the limit switch failed. On the second lowering, the limit switch operated only after the crew manually reset it.
74 SOLAS (14) III/34
LSA V/ 6.1.2.7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 8 October 2021
Resolution: Received class report attesting to satisfactory repair.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 6 March 2017
Resolved
0611-Lifeboat Inventory- Food rations shall be kept in airtight packaging. PSCO observered a total of 9 non-airtight food ration packaging; 5 on the port lifeboat and 4 on the starboard lifeboat. 74 SOLAS (14) III/34 LSA 4.4.8.12 17c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2017
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Communications › Radio Communications › EPIRB
Issued 6 March 2017
Resolved
1673-VHF EPIRB- Hydrostatic release units shall be serviced at intervals not exceeding 12 months. PSCO observed hydrostatic release unit for the EPIRB was expired. 74 SOLAS (14) III/9.1 17c
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2017
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 6 March 2017
Resolved
0690-Line Throwing Appliance- Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed line-throwing appliances were expired on January 2017. 74 SOLAS (14) III/20.2 17c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2017
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Lifesaving › Launching Appliances › Davit
Issued 10 September 2011
Resolved
0610 Each lifeboat shall be provided witha n appliance which is capable of launching and recovering the lifeboat. After lowering the port side lifeboat; the crew was unable to raise/recover the lifeboat dut to inoperable davit motor. SOLAS 74(AMEND) 2009 CONS. ED. CH.III Reg. 16.2 17A/C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2011
Resolution: PSCO recieved class report All sat.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 8 January 2010
Resolved
Starboard side anchor windlass hydraulic motor was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2010
Resolution: Received, reviewed and accepted class report from [name withheld] stating the anchor windless was repaired, tested and found satisfactory.
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 February 2009
Resolved
Vessel has a INOP S-Band radar, vessel has stated that a tech is going to attend the vessel while at the pier.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2009
Resolution: Tech report received, radar in good working order.
Accommodation/Occupational Safety › Ventilation › General
Issued 14 April 2008
Resolved
0510- Ventilation Heating work spaces- Air intake ducting for main A/C ventilator is wasted and holed in A/C room. This could aid in the spread of fire through the ventilation system even when ventilation is secured. Rectify to satisfaction of flag/class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 April 2008
Resolved 7 May 2008
Resolution: As per Lloyd''s Register Statement Certificate #GUY800078 dated 29Apr08 via e-mail. Air ducts are now temporarily repaired, new ducts are planned to be installed 28 JULY 2008 during the call of the ship to Talachauno- Chile. A memoranda is now in place.
Construction/Loadline › Structures › Superstructure
Issued 14 April 2008
Resolved
1299- Other (Load Lines)- Forward bulkhead of house adjacent to cargo deck has numerous stress cracks beneath lower corners of accommodation windows. These could allow weather/water into house or dangerous vapors from cargo. Address to satisfaction of class/flag.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 April 2008
Resolved 7 May 2008
Resolution: As per Lloyd''s Register Statement Certificate #GUY800078 dated 29Apr08 via e-mail from ship agent. Repairs completed in accordance with original specifications.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 26 September 2006
Resolved
The #1 battery set is unable to start the emergency generator which prevents the vsl from demonstrating second means of starting. Class is to verify repairs on behalf of the administration prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2006
Resolution: Recieved class report stating "Emergency generator was verified and tested with both means of startig (Battery bank no. 1 and 2) wth satisfactory results."