MAURY USCG vessel records
← All vessels

AZTEC

Built
2003
Last inspected
11 December 2023
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 December 2023
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9265354
644272
Flag
PANAMA
Maury page id
psix-644272

Documentation record

Tonnage as PSIX records it39085 - Convention (Subpart B), Gross Ton
19936 - Convention (Subpart B), Net Ton
81464 - Displacement, Metric Ton
68439 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 13 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 13

11 December 2023 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7833744
24 May 2022 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7458410
24 May 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7470268
9 March 2022 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7407969
8 March 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7407818
27 December 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7372796
3 November 2021 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7344634
8 October 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329374
31 August 2021 PSC B · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7294527
10 January 2018 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6331739
6 March 2017 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6099371
27 January 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5804883
20 January 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5800323

Deficiency record · 7

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 May 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed 5 foot by 3 foot puncture in Bosun Storage, Frame 111. Require damage assessment to include all adjacent compartments, tanks, and bulbous area for damage. 74SOLAS (20) I/11(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 25 May 2022
Resolved 15 June 2022
Resolution: Received, reviewed and approved class report from LR verifing vessel's repairs were completed and approved by approved technician and Class.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 9 March 2022 Resolved
EVERY STEAM PIPE AND EVERY FITTING CONNECTED THERETO THROUGH WHICH STEAM MAY PASS SHALL BE SO DESIGNED, CONSTRUCTED AND INSTALLED AS TO WITHSTAND THE MAXIMUM WORKING STRESSES TO WHICH IT MAY BE SUBJECTED. PSCO OBSERVED LEAKS ON STEAMLINES LOCATED NEAR TANKS ONE PORT AND SIX STARBOARD. 74 SOLAS(04) II-1/33.1 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 March 2022
Resolution: Steam heating pipe for cargo tank No.1P and No.6S were cropped and renewed. Three valves were replaced w/ new spares. Steam heating pipes has been renewed, installed and tested successfully.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 November 2021 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL REPORTED PARTIAL LOSS OF PROPULSION WHILE TRANSITING DELAWARE BAY. VESSEL MUST PROVIDE A CLASS REPORT WITH A CAUSAL ANALYSIS OF THE LOSS OF PROPULSION AND COMPLETION OF REPAIRS PRIOR TO MOVEMENT.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 November 2021
Resolution: Received Class report;the issue was traced to the air in the fuel oil (fo)counter meter.Once the counter meter was bypassed and the fo line was purged,the fo pressure returned to normal (8 bar).
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 31 August 2021 Resolved
Safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops to prevent overstressing the fall or davits. While retrieving the starboard side life boat, the first activation of the limit switch failed. On the second lowering, the limit switch operated only after the crew manually reset it. 74 SOLAS (14) III/34 LSA V/ 6.1.2.7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 8 October 2021
Resolution: Received class report attesting to satisfactory repair.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 6 March 2017 Resolved
0611-Lifeboat Inventory- Food rations shall be kept in airtight packaging. PSCO observered a total of 9 non-airtight food ration packaging; 5 on the port lifeboat and 4 on the starboard lifeboat. 74 SOLAS (14) III/34 LSA 4.4.8.12 17c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2017
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Communications › Radio Communications › EPIRB
Issued 6 March 2017 Resolved
1673-VHF EPIRB- Hydrostatic release units shall be serviced at intervals not exceeding 12 months. PSCO observed hydrostatic release unit for the EPIRB was expired. 74 SOLAS (14) III/9.1 17c
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2017
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 6 March 2017 Resolved
0690-Line Throwing Appliance- Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed line-throwing appliances were expired on January 2017. 74 SOLAS (14) III/20.2 17c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2017
Resolution: PSC NOLA received a class report from LR satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.