MAURY USCG vessel records Sign in
← All vessels

MAERSK MICHIGAN

MAERSK MICHIGAN is a 2002 tank ship. The Coast Guard has recorded 65 inspections since 2003, most recently in June 2023, along with 66 deficiencies, 4 operational controls and 10 casualty investigations between 2010 and 2018.

Records from 2003 to 2023. Most recent: inspection, 20 June 2023.

Built
2002
Last inspected
20 June 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9255244 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
644961
Flag
PANAMA
367393000
Maury page id
psix-644961

Inspections, by type

…with no type recorded12
Years with a record 19 calendar years (2003–2023)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28517 - Convention (Subpart B), Gross Ton
12385 - Convention (Subpart B), Net Ton
47047 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WGDWMMSI 367393000 · active · compulsorily equipped · granted 6 September 2018, expires 6 September 2028
WGDWMMSI 367393000 · terminated · compulsorily equipped · granted 31 July 2008, cancelled 5 September 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

20 June 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7718605
25 January 2023 Administrative Inspection
Administrative · Activities Europe · Activity 7626698
12 January 2023 Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7620376
31 October 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7586352
7 September 2022 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7554822
24 June 2022 Administrative Inspection · Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification · ISM Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7485602
23 September 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7318542
15 September 2021 Drydock Exam · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7345080
8 July 2021 Periodic Inspection · MTSA/ISPS Verification · MSP Periodic Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7250180
4 June 2021 Liferaft Servicing
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7215036
19 April 2021 Internal Structural Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7178805
10 March 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7153382
18 December 2020 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7113536
19 November 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7108022
18 November 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7097399
2 July 2020 Annual Inspection · MSP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6973395
28 May 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6962248
20 February 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6912132
19 August 2019 Ballast Water Examination · Annual Inspection · MSP Annual Oversight
Physical examination · Activities Europe · Activity 6787682
20 December 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6600612
13 December 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6597195
16 May 2018 MTSA/ISPS Verification · Drydock Exam · Internal Structural Exam · COI Inspection · MSP COI Oversight
Physical examination · Activities Europe · Activity 6415785
22 February 2018 Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 6360086
21 February 2018 Type not recorded
No type recorded · Activities Europe · Activity 6365752
31 January 2018 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6351213
25 January 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6344064
21 January 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6341149
21 January 2018 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6382668
14 November 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6306347
12 November 2017 Type not recorded
No type recorded · Activities Europe · Activity 6306349
1 July 2017 Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7541392
7 June 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6186868
20 May 2017 Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6150713
28 December 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6063026
2 November 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6033676
25 May 2016 Annual Inspection · DAPI Audit · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 5886211
8 March 2016 Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 5828972
23 February 2016 Type not recorded
No type recorded · Activities Europe · Activity 5820057
16 February 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5815507
7 January 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5793140
13 November 2015 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 5764892
5 October 2015 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5736476
17 July 2015 Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5163670
13 August 2014 Administrative Inspection
Administrative · Activities Europe · Activity 4953340
28 March 2014 Administrative Inspection
Administrative · Activities Europe · Activity 4824673
12 June 2012 Type not recorded
No type recorded · Activities Europe · Activity 4347446
7 December 2011 Excursion Permit
Administrative · Activities Europe · Activity 4203467
4 December 2010 Type not recorded
No type recorded · Activities Europe · Activity 3904860
8 November 2010 COI Inspection
Physical examination · Commandant (CG-CVC) · Activity 3887033
14 September 2010 Annual Inspection
Physical examination · Activities Europe · Activity 3819018
1 January 2010 Administrative Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 3661783
11 December 2009 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Activities Europe · Activity 3648401
5 May 2009 Administrative Inspection
Administrative · Activities Europe · Activity 3467731
4 February 2009 In-Service Inspection
Physical examination · Activities Europe · Activity 3412233
29 June 2008 Internal Structural Exam · Administrative Inspection · Hull Examination · Reflagging & Initial Certification · MTSA Verification · Cargo Tank Internal · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3276884
12 October 2006 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2799429
5 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2508182
30 August 2005 MARPOL Annex I Examination · MARPOL Annex V Examination · COC-CHEM Renew · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2478598
23 June 2005 Random ISPS/MTSA/PSC
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2400702
10 June 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2386343
11 May 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2355452
28 December 2004 NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2265721
12 August 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2163916
8 August 2004 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2159736
23 August 2003 MARPOL Annex I Examination · Ballast Water Examination · Certificate of Compliance
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1880333

Deficiency record · 66

02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 17 July 2022 Resolved
Conditions of the ship and its equipment shall be maintained to conform with regulations to ensure ship remains fit for sea without danger to ship or persons onboard. Following items require maintenance on cargo deck: 1. Missing containment plug by deck water seal 2. Deteriorated electrical cabling fitting by deck water seal 3. Disconnected grounding cable (8P overhead piping by centerline) 4. New flame screen #6S Aft WBT vent 5. Corroded electrical conduit ivo #2S Foam Hose station 6. Missing supports for shower piping (P, C, S) 7. Corroded electrical conduit box (Stbd manifold, aft #5S) 8. Safe access to bow houses filled with equipment 9. Replace PV breaker TLI sight glass 10. Replace #1C tank cover gasket 11. Corroded aft #1C IG inlet electrical conduit 12. Replace broken latch on swing door (Port Bow) 13. Air leak ivo fwd stbd anchor deck - air line connection to deck underneath grating 14. Mechanical plugs missing at multiple containment boxes Repairs due within 30 days to satisfaction of RO. Cite - 74SOLAS(2020)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2022
Resolved 26 July 2022
Resolution: See attached RO report
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 July 2022 Resolved
Life-saving appliances shall be in working order and ready for immediate use. Medical kits for ship's liferafts expired June2022 and annual liferaft servicing not due until September2022. Spare medical kits to be provided at muster location for expired medical items. Mitigation plan to be submitted and servicing completed within 30 days to replace expired items. Cite - 74SOLAS(2014)III/20.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2022
Resolved 26 July 2022
Resolution: See attached RO report
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 July 2022 Resolved
Life-saving appliances shall be in working order and ready for immediate use. Liferaft painter line incorrectly attached to the vessel, not the weak link. Ship fixed during inspection and verified by USCG [name withheld] - 74SOLAS(2014)III/20.2
Action required: 10 - Deficiency Rectified
Resolved 17 July 2022
Resolution: Verified by attending MI.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 July 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 17 July 2022
Resolution: Verified by attending USCG MI.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 July 2020 Resolved
Rescue Boats-Before the ship leaves port and at all time during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. 01-Observed rescue boat davit limit switch missing, follow risk mitigation plan. 02-improper penetration & loose wire connection IWO winch. 03-unserviceable retro-reflective tape STBD side of Rescue boat. SOLAS 74a (04)III/20.2 50a, #3-10c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 July 2020 Resolved
One or more pressure/vacuum breaker devices shall be provided to prevent the cargo tanks from being subject to a positive or negative pressure. PV breaker water is low showing inaccurate pressure reading of IG line and not providing protection as designed. SOLAS 74a (04) II-2/11.6.3.4 50a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 July 2020 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. Found Pressure gauge junction boxes unsecured and holed for: 1 P/S, 3 P/S, 4 P/S, 8 P/S. SOLAS 74a (04)ll-l/45.11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 2 July 2020 Resolved
One or more pressure/vacuum breaker devices shall be provided to prevent the cargo tanks from being subject to a positive or negative pressure. PV breaker water is low showing inaccurate pressure reading of IG line and not providing protection as designed. SOLAS 74a (04) II-2/11.6.3.4, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 2 July 2020 Resolved
An immersion suit of an appropriate size complying with the requirements of section 2.3 of the Code shall be provided for every person on board the ship. Vessel conducting seam test of immersion suits at three year intervals, majority of suits manufactured in 2005 and are over ten years of age. For immersion suits over 10 years of age shall conduct seam test at intervals not exceeding one year. 74 SOLAS(2004)III/32.3.3 MSC/Circ.1047 10c
Action required: 10 - Deficiency Rectified
Resolved 2 July 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 July 2020 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to the ship or persons on board. Found several pipe bonding straps speared or missing in particular IWO deck water seal. Identify and repair/replace as original. SOLAS 74a (14) I/11(a) 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 2 July 2020 Resolved
On a tankship, each cargo tank must be equipped with an overfill device. Found 7S COT overfill alarm was active and could not be reset, verified tank level (Cont) below 98%. Vessel is restricted to filling tank no greater than 95% until repaired. 33 CFR 155.480 705a
Action required: 705 - Other - as specified
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 2 July 2020 Resolved
Satisfactory means shall be provided for the protection of the crew in getting to and from all other parts used in the necessary work of the ship. Found Catwalk structure forward of pump room to be severely wasted, holed and unsafe for use. Repair prior to use. ILLC 66 Annex I/16 705a
Action required: 705 - Other - as specified
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 July 2020 Resolved
dentify “TANK OVERFILL ALARM” in black letters at least 2" high on a white background. Vessel tank overfill alarm signage was faded and red on white. 46CFR 39.2007(d)(2) 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 July 2020 Resolved
The lights and shapes specified in these rules shall comply with the provisions of Annex I. Found Christmas tree lights housing with water and one light out. 72 COLREGs Rule 20 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 July 2020 Resolved
All ships shall have; a receiver for global navigation satellite system. Found GPS antenna mount to be unsecured and loose. 74 SOLAS (14) V/19.2.6 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
Resolution: 27JUL2020: Received ABS report #4368872, Sat repair.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 July 2020 Resolved
Each life raft or group of life rafts shall be stowed with a float-free arrangement. Observed 01 life raft with the HRU not secured to cradle. SOLAS 74a (04)III/13 10c
Action required: 10 - Deficiency Rectified
Resolved 2 July 2020
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 19 August 2019 Resolved
Prior to conducting cargo loading operations replace teh pressure vent valve for cargo tank number 4 also excercise and repair the vaccum valve on cargo tank number 6. 74SOLAS(14) II-2/6.1
Action required: 10 - Deficiency Rectified
Due 26 August 2019
Resolved 26 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 August 2019 Resolved
Illustrations and instructions in appropriate languates shall be conspicoulsy displayed at muster station for the method of donnign lifejackets. SOLAS (14) III/8.4.3
Action required: 10 - Deficiency Rectified
Due 26 August 2019
Resolved 26 August 2019
Resolution: Posted
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 19 August 2019 Resolved
The emergency stop located at the port mainfold shall bomply with cables and wiring installed in hazardous zones, this items shall be rapired prior to cargo opearations. The enclosure box is wasted away and should be replaced in the next 30 days. SOLAS II-1/45.11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2019
Resolved 3 September 2019
Resolution: Recieved pictures and an email from the vessels master attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 August 2019 Resolved
Cylinders must alwways be scured and when onot in use must be stowed in a rack in an upright position, with the valve protection cap in place. The argon gas for calibraiton for the flue gas system was being stowed strapped to handrail in the upper engineroom. 46CR47.60
Action required: 10 - Deficiency Rectified
Due 26 August 2019
Resolved 26 August 2019
Resolution: MOVED buliding a rack for long term storage near the IG system.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 August 2019 Resolved
The turbochargers on both No. 1 and 2 Generators are missing the lagging around the exhaust side of the turbo leaving high temperature surfaces exposed. SOLAS II-2.2.6
Action required: 10 - Deficiency Rectified
Due 26 August 2019
Resolved 26 August 2019
Resolution: Crew found the missing lagging and installed.
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2018 Resolved
The bilge holding tank at frames 13-17 suffered a 1.5cm hole in the hull plating. Temporary plate and cement patches were applied. The crew shall monitor the condition of the patch and report any change of conditions to the USCG. Permanent repairs are are due during the next drydock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 July 2018
Resolved 29 July 2018
Resolution: Repaired during drydock in Duqm, Oman.
Lifesaving › Launching Appliances › Davit
Issued 21 January 2018 Resolved
Make necessary repairs to vessel's hydraulic ram on the free fall lifeboat davit. Repairs and operational testing to be completed to the satisfaction of OCMI prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2018
Resolved 8 March 2018
Resolution: Uploaded ABS report into MISLE.
Engineering › Freshwater System (cylinder head cooling) › Pump
Issued 11 July 2017 Resolved
Make repairs to #1 circ pump discharge outlet pipe.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 2 August 2017
Resolution: Vessel replaced flanged on circ pump, master provided pictures.
Communications › Alarms/Indicators › General Alarm
Issued 11 July 2017 Resolved
Make operable #1 center cargo tank high pressure alarm.
Due 11 August 2017
Resolved 2 August 2017
Resolution: Vessel provided tech reports stating the alarm was repaired.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 11 July 2017 Resolved
Make operable the port slop tank level indicator.
Due 11 August 2017
Resolved 3 August 2017
Resolution: Vessel made repairs to the slop tank level indicator.
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 7 June 2017 Resolved
Rescue boat steering was found faulty during routine maintenance . Worn out plastic cable guide. Secondary steering (Tiller} installed tested and demonstrated to crew .
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 21 June 2017
Resolution: Received work order reciept confirming repairs and satisfactory operational tests of the Rescue boat from IFTEC repair facility.
Engineering › Diesel Engine (auxiliary) › Nozzle, Injection (fuel injection)
Issued 13 June 2016 Resolved
Replace old, fuel soacked lagging on fuel supply line beneath deck plating on all ship service generators and beneath the deck plates on both fuel oil purifier units.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 June 2016
Resolution: Lagging has been replaced.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 13 June 2016 Resolved
Properly install lagging on #2 ship service diesel generator exhaust elbow
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 June 2016
Resolution: Lagging was installed on #2 SSDG exhaust elbow
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 13 June 2016 Resolved
Properly install lagging on piping near ship service diesel generator fuel oil boost pumps leading to the filtering unit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 July 2016
Resolved 15 June 2016
Resolution: Lagging was correctly installed.
Lifesaving › Lifeboat › Propulsion Engine
Issued 16 February 2016 Resolved
Inoperable lifeboat engine
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 3 March 2016
Resolution: Rcvd email from vessel master stating that the Lifeboat is now operating properly after completion of the repairs and ABS Class surveyor has re-issued their Cargo Ship Safety Equipment Certificate.
Construction/Loadline › Markings › Load Line Mark
Issued 8 November 2010 Resolved
repaint loadline in contrasting color
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 26 April 2011
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 14 September 2010 Resolved
Provide USCG approval letter for the onboard Automated Test Procedures (rev1.6). Current onboard approval letter is for revision 1.4.
Action required: 705 - Other - as specified
Due 14 October 2010
Resolved 14 October 2010
Documentation › Safety Management System › Safety/Environmental Protection Policy
Issued 8 January 2010 Resolved
Provide Non-Conformity Report/Corrective Action Report addressing failure to conduct proper installation plan review for electrical installations related to emergency lighting and new lifesaving arrangements. (see narrative for detailed explanation)
Condition: Unknown
Due 22 January 2010
Resolved 15 January 2010
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 8 January 2010 Resolved
Submit Non-Conformity Report (copy ACTEUR) concerning general failure to follow approved installation plans (where plans were submitted and approved by ABS).
Condition: Unknown
Due 22 January 2010
Resolved 15 January 2010
Lifesaving › Rescue Boat › Carriage Requirement
Issued 1 January 2010 Resolved
Vessel crew to conduct underway launch test of new rescue boat at 5 kts vessel speed, and make report to USCG Activities Europe.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 January 2010
Resolution: Received email report from Master attesting to satisfactory launch underway.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 December 2009 Resolved
Hydrostatically test all portable fire extinguishers which have not been tested in more than 5 years.
Action required: 705 - Other - as specified
Due 16 January 2010
Resolved 18 January 2010
Resolution: Received report of hydrotest of 2 fire extinguishers from Captain.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 15 December 2009 Resolved
Emergency Generator fuel oil tank is wasted and in need of repair.
Due 16 January 2010
Resolved 19 January 2010
Resolution: Received photos attesting to replacement. Def noted fuel oil tank, should be tank vent head--which was repalced.
Fire Fighting › Portable Foam Applicators › General
Issued 15 December 2009 Resolved
Provide sufficient number of portable foam fire extinguishers in accordance with SOLAS 74/78 Ch II-2, Reg.5.2.2.2
Condition: Unknown
Due 16 January 2010
Resolved 18 January 2010
Resolution: Received purchase order for new foam extinguisher unit.
Lifesaving › Lifeboat › Carriage Requirement
Issued 16 March 2009 Resolved
Replace existing port and starboard lifeboats/rescueboat and launching appliances with USCG approved lifeboats, rescue boat and launching appliances.
Due 15 August 2009
Resolved 15 December 2009
Resolution: Item to be changed to more stringent 835 issued 16Dec09.
Engineering › Compressed Air System (start air) › Valve
Issued 18 September 2008 Resolved
Provide pressure relief valves for main air pressure vessels in engine room. Cleared via email. Will verify at next USCG inspection.
Due 7 September 2009
Resolved 15 December 2009
Resolution: Relief valves present and operated properly.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 18 September 2008 Resolved
Provide a Coast Guard approved rescue boat IAW 46 CFR 199.262, with embarkation and launching arrangements IAW 46 CFR 199.160. Submit plans for Coast Guard approval prior to installation.
Due 18 December 2008
Resolved 16 March 2009
Resolution: Rescinded deficiency by ACTEUR OCMI letter dated 16 March 2009.
Lifesaving › Launching Appliances › Release Mechanism
Issued 18 September 2008 Resolved
Submit plans to CG for the replacement of the lifeboat release gear. Plans must be approved prior to installation of any replacement release gear. Until lifeboat release gear can be renewed, lifeboat drills should be conducted with minimum crew and should not include release of the lifeboat. The functional test of the release hooks should be conducted w/ vessel stowed, utilizing stand off gear.
Due 17 March 2009
Resolved 16 March 2009
Resolution: Rescinded by ACTEUR OCMI letter dated 16 Mar 2009.
Lifesaving › Launching Appliances › Release Mechanism
Issued 7 September 2008 Resolved
Provide servicing report from manufacturer's rep attesting to proper operation of rescue boat release gear prior to departure from Fujairah, UAE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2008
Lifesaving › Rescue Boat › Propulsion Engine
Issued 7 September 2008 Resolved
Provide servicing report from manufacturer's rep attesting to proper operation of rescue boat engine prior to departure from Fujairah UAE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2008
Lifesaving › Lifeboat › Markings
Issued 7 September 2008 Resolved
Stencil/mark all lifesaving equipment including lifeboats and liferafts with vessel's new name.
Due 7 October 2008
Resolved 18 September 2008
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 7 September 2008 Resolved
Provide four complete fire suits that meet NFPA 1971-2000, complete with all req'd SOLAS equipment. Cleared by email, will verify at next USCG attendance.
Due 7 September 2009
Resolved 15 December 2009
Resolution: All items in ensembles meed NFPA 1971-2000 and documentation is present.
Fire Fighting › Fire Pumps › Arrangement
Issued 7 September 2008 Resolved
Prove proper operation of emergency fire pump (prime pump in ballast condition)
Due 7 October 2008
Resolved 18 September 2008
Communications › Radio Communications › EPIRB
Issued 7 September 2008 Resolved
Properly install EPIRB
Due 7 October 2008
Resolved 18 September 2008
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 7 September 2008 Resolved
Complete damage control scenario, provide damage control plan.
Due 7 October 2008
Resolved 7 September 2008
Lifesaving › Launching Appliances › Davit
Issued 7 September 2008 Resolved
Provide lifeboat and rescue boat davit cradle securing gear.
Due 7 October 2008
Resolved 18 September 2008
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 7 September 2008 Resolved
Prove proper operation of #3P cargo oil tank high level visual alarm (cargo control room console)
Due 7 October 2008
Resolved 18 September 2008
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 7 September 2008 Resolved
Inspect/test IG safety/shutdowns
Due 7 October 2008
Resolved 7 September 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 7 September 2008 Resolved
Prove proper operation of cargo pump emergency stops from main deck.
Due 7 October 2008
Resolved 7 September 2008
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Operation Controls
Issued 7 September 2008 Resolved
Provide plan that ensures time delay prior to activation of fixed foam system.
Due 7 October 2008
Resolved 18 September 2008
Fire Fighting › Nozzles › Condition
Issued 7 September 2008 Resolved
Repair slide-brake on #3 fire monitor.
Due 7 October 2008
Resolved 18 September 2008
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 7 September 2008 Resolved
Make hospital space ready for immediate use.
Due 7 October 2008
Resolved 18 September 2008
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 7 September 2008 Resolved
Prove proper operation of incinerator. Cleared by email, test report dated 4 Nov 08. Will verify during next USCG inspection visit.
Due 7 September 2009
Resolved 4 November 2008
Resolution: Incinerator operated satisfactorily.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 7 September 2008 Resolved
Provide warning placards at MSD overboard discharge to prevent discharge of sewage.
Due 7 October 2008
Resolved 18 September 2008
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 7 September 2008 Resolved
Provide USCG approval letter for Vessel Response Plan/SMPEP. Application for plan verified. Will verify at next USCG attendance.
Due 7 September 2009
Resolved 15 December 2009
Resolution: Viewed the VRP/SMPEP approval letter.
Fire Fighting › Ventilation Systems › Grouping
Issued 7 September 2008 Resolved
Properly label all fire damper access covers indicating "fire damper".
Due 7 October 2008
Resolved 18 September 2008
Communications › Alarms/Indicators › General Alarm
Issued 7 September 2008 Resolved
Provide placards at general alarm bells that state "General Alarm, when emergency alarm signal rings go to your station" in red letters at least 1/2inch high.
Due 7 October 2008
Resolved 18 September 2008
Documentation › Manuals/Policy Documentation › Crude Oil Washing Operations/Equipment Manual
Issued 12 October 2006 Resolved
Vessels COW manual is not marked with the approval of the Government of the Flag State.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2008
Resolution: Valid COW manual onboard at time of MSP reflag exam.
Construction/Loadline › Structures › Air Pipe
Issued 12 October 2006 Resolved
Inspectors unable to verify if the Alterations to the vessels stern tube vent line have been approved by the administration. A 15 foot piece of flexible plastic hose has been added to the fixed stern tube vent line located adjacent to the oxygen analyzer
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 September 2008
Resolution: Attending ABS surveyor during MSP reflag had no issues with arrangement.
Deck/Cargo › Cargo Stowage › General
Issued 29 August 2005 Resolved
Vessel has no visible/audible "High Alarm" on cargo deck. Vessel is not to load in US waters until permanent repairs are made.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 August 2005
Resolved 7 September 2005
Resolution: Received class report clearing vessel of def.
Documentation › Certificates/Documents
Issued 23 August 2003 Resolved
Remove item #3 from the International Certificate of Fitness where it is indicated that the vessel is an "incinerator ship" the vessel does not have an incinerator that meets IBC/19. LEGACY COMPONENT DESC: Certificate of Fitness
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 August 2003
Resolution: Received fax from ABS nullifying item #3 of the Certificate Fitness.

Casualty record · 10

16 May 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3838590
4 December 2010Routine · role: Involved in a Marine Casualty · activity 3904860
7 March 2011Routine · role: Involved in a Marine Casualty · activity 3968367
6 March 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4264995
12 June 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4347446
22 January 2014Routine · role: Involved in a Marine Casualty · activity 4789219
23 February 2016Routine · role: Involved in a Marine Casualty · activity 5820057
12 November 2017Routine · role: Involved in a Marine Casualty · activity 6306349
21 January 2018Routine · role: Involved in a Marine Casualty · activity 6382668
21 February 2018Routine · role: Involved in a Marine Casualty · activity 6365752
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.