MAURY USCG vessel records
← All vessels

BACALIAROS

BACALIAROS is a 2003 tank ship. The Coast Guard has recorded 7 inspections since 2016, most recently in October 2019, along with 2 deficiencies and 1 operational control.

Records from 2016 to 2019. Most recent: inspection, 23 October 2019.

Built
2003
Last inspected
23 October 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 October 2019
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9233777
645126
Flag
MARSHALL ISLANDS
Maury page id
psix-645126

Documentation record

Tonnage as PSIX records it81310 - Convention (Subpart B), Gross Ton
46385 - Convention (Subpart B), Net Ton
160209 - Dead Weight, Metric Ton
183044 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

23 October 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6836335
4 April 2018 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6384923
23 January 2018 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6338310
25 November 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6047407
8 July 2016 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5934187
16 June 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5909411
14 January 2016 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5792390

Deficiency record · 2

12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 23 October 2019 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions, against such risks shall be taken to the satisfaction of the administration. Temperature sensing devices on all three cargo pumps are not installed in an explosion proof manner due to exposed wires. Cargo pump #1: bearing, casing, lower shaft; Cargo pump #2: bearing, lower shaft, upper shaft; Cargo pump #3: bearing, lower shaft, upper shaft. Ground on light in forward part of lower pump room missing. Correct prior to cargo. SOLAS 09 II-1/45.5.4
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2019
Resolved 24 October 2019
Resolution: Prior to cargo def cleared by class, MI attended vessel and endorsed COC.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 October 2019 Resolved
The following fire protection system shall be kept in good order so as to ensure their required performance if a fire occurs. Structural fire protection, including fire-resisting divisions. PSCO observed the door from the galley scullery to the officers mess room to have deformities on the hinge side causing the door to not be self-closing. SOLAS 09 II-2/14.2.1.1.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 23 October 2019
Resolved 23 October 2019

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.