MAURY USCG vessel records
← All vessels

DURABLE

DURABLE is a 2003 industrial vessel. The Coast Guard has recorded 5 inspections since 2019, most recently in April 2025, along with 4 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 2019 to 2025. Most recent: inspection, 15 April 2025.

Built
2003
Last inspected
15 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Identity

9242376
645726
Flag
MARSHALL ISLANDS
Maury page id
psix-645726

Inspections, by type

…with no type recorded1
Years with a record 5 calendar years (2019–2025)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it16148 - Displacement, Ton
12184 - Simplified, Gross Ton
3655 - Simplified, Net Ton
9200 - Dead Weight, Metric Ton
12184 - Convention (Subpart B), Gross Ton
3655 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

15 April 2025 PSC B
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8112677
29 December 2024 In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8051891
11 March 2022 Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7409980
6 May 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6945898
3 January 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6604954

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 March 2022 Resolved
07106 - Any required fixed fire detection and fire alarm system with manually operated call points shall be capable of immediate operation at all times. PSCO observed the smoke detection alarm system was in fault. 74 SOLAS (2001) II-2/13.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2022
Resolved 17 March 2022
Resolution: Technician attended vessel and cleared system fault, all in good working order.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 March 2022 Resolved
07116 - Machinery spaces of category "A" shall be adequately ventilated. PSCO observed port side outboard ventilation fan not operational and fire dampers not able to be secured. 74 SOLAS (2001) II-1/35
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2022
Resolved 17 March 2022
Resolution: Technician attended vessel and class report states that ventilation fan an fire dampers are in good working order
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 11 March 2022 Resolved
01117 - After any survey of the ship, no changes shall be made in the structure, equipment, systems, fittings, arrangements, or materials. PSCO observed unapproved modification to piping after 3-way valve on OWS. MARPOL ANNEX I/6.4.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2022
Resolved 17 March 2022
Resolution: OWS piping arrangement IAW the piping diagram approved for OWS
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 11 March 2022 Resolved
14799 - Any vessel equipped with ballast water tanks that operates in waters of the U.S. must remove fouling organisms from the vessel's hull. PSCO observed algae growth on the hull. 33 CFR 151.2050(f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2022
Resolved 17 March 2022
Resolution: Fouling organisms removed from hull