MAURY USCG vessel records Sign in
← All vessels

LANCASHIRE

LANCASHIRE is a 2000 freight ship. The Coast Guard has recorded 5 inspections since 2000, most recently in January 2004, along with 4 deficiencies and 2 operational controls.

Records from 2000 to 2004. Most recent: inspection, 22 January 2004.

Built
2000
Last inspected
22 January 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9162629 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
BAHAMAS, THE
—
Maury page id
psix-6470

Inspections, by type

…with no type recorded2
Years with a record 3 calendar years (2000–2004)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it24836 - Convention (Subpart B), Gross Ton
7450 - Convention (Subpart B), Net Ton
14254 - Dead Weight, Ton
24098 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

22 January 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1990708
2 August 2002 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1656043
29 July 2002 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1653900
2 May 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 277476
28 April 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 277450

Deficiency record · 4

Communications › Alarms/Indicators
Issued 22 January 2004 Resolved
Prove proper operation of the ships general alarm. to the satisfaction of class (LR). LEGACY COMPONENT DESC: General Alarm
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2004
Resolution: Received class report from Lloyd''s Register dated 22 January 2004 stating, Deficiency was traced to a burned 1.5 A fuse in the power supply for the General Alarm. Replaced fuse and alarm satisfactorily tested.
Personnel › Certificates/Documents/Licenses
Issued 22 January 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2004
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 22 January 2004 Resolved
Have class (LR) inspect repairs to the storm damage in the UPS and Battery room. LEGACY COMPONENT DESC: UPS And Battery Room
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2004
Resolution: Received class report from Lloyd''s Register dated 22 January 2004 stating, Temporary repairs in the UPS battery room are satisfactory.
Engineering
Issued 28 April 2000 Resolved
EXHAUST LEAK IN STACK PIPING ABOVE GENERATORS IN ENGINE ROOM.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000

Ownership record