Records from 2007 to 2025. Most recent: inspection, 28 October 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2026
Resolved
An inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails. Replace incorrect topmast shroud pin with the correct shroud pin and clevis pin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2026
Resolved 22 June 2026
Resolution: See photos.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 August 2025
Resolved
Ring buoy grab line is weathered, weakened, wasted. Replace ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2025
Resolved 22 August 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 August 2025
Resolved
Vessel is missing logs of inspections of the rig in accordiance with the rig and inspection program. Provide copy of logged rig inspection after 30 days.
Action required: 705 - Other - as specified
Due 12 September 2025
Resolved 8 September 2025
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 11 August 2025
Resolved
All cable and wire must be installed with metal supports
spaced not more than 24 inches apart and must be installed properly. Midship cabin area stbd side light electrical cables were found supported with tape and exposed wiring. Properly install the electrical cable to light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2025
Resolved 22 August 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2025
Resolved
Cable and wire must not be installed with sharp bends. Midship cabin area port side cable bundle has sharp bends in the cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2025
Resolved 22 August 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 August 2025
Resolved
The movement of the vessel shall be under the direction and control of the licensed master. Provide copy of the medical card that accompanies the master's license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 22 August 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Monitor water ingress for 14 days, and report findings to this office. Establish a bilge log reflecting the gallons per minute of water ingress; maintain and present this log to inspectors during future inspections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2024
Resolved 31 May 2024
Resolution: Bilge water ingress slowed significantly, to the satisfaciton of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 May 2024
Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. On systems in which the CO2 cylinders are not within the protected space, these instructions must also include a diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate. CO2 instructions have been painted over.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 31 May 2024
Resolution: Instructions marked properly.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge Marine Inspection, as good marine practice. Replace Jib topmast stay turnbuckle with longer 3/4" turnbuckle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 31 May 2024
Resolution: Turnbuckle replaced as discussed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Gammon iron to forestay bolt shall be replaced with a solid bolt with threads outside of flange. Current bolt allows the stay to land on the threads. Include bushings/spacers on either side of the forestay to prevent the stay from sliding on the bolt.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 31 May 2024
Resolution: Bolt found sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Replace starboard foretopmast shroud turnbuckle. The jib top shall not be flown until this turnbuckle is received and approved by a reviewing MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 31 May 2024
Resolution: Turnbuckle replaced as discussed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2024
Resolved
It is intended that all machinery be installed in such a manner to afford protection against personnel injury. Add machinery guard around bilge pump belts in way of the front of the main engine to prevent injury.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 31 May 2024
Resolution: Machinery Guard Installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Fabricate a well ventilated box to protect the gasoline fire pump on deck. The box should be easily removable and indicate that "NO SMOKING" and "NO SITTING' is allowed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 31 May 2024
Resolution: Cover constructed as discussed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Check fire pump fuel level prior to getting underway at a minimum once a week, while the vessel is in service, to ensure that the fuel tank remains full of good fuel. The results of the check should be logged. Provide this office with the run time of the pump under load on a single tank of fuel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 31 May 2024
Resolution: Completed as discussed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 June 2023
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage and to effect permanent repairs. Following a collision on June 28th 2023, which ripped the vessel's bowsprit off, Marine Inspectors observed damage in way of the bow, and radiating throughout the vessel as a result of the collision. Vessel is required to undergo a Coast Guard Dry Dock and Internal Structural Examination, and effect permanent repairs to damage that is identified by the attending Marine Inspector prior to returning to service.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 29 June 2023
Resolved 24 May 2024
Resolution: Repairs were completed to the satisfaction of the attending Marine Inspectors. See activities 7771212 and 7898093 for additional information.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 June 2023
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Following a collision on June 28th 2023, which ripped the vessel's bowsprit off, Marine Inspectors observed damage in way of the bow, and radiating throughout the vessel as a result of the collision. A rig survey is required prior to the vessel's return to service. Prior to completing the survey, contact this office for approval to proceed, and to orchestrate CG attendance at the survey.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2023
Resolved 24 May 2024
Resolution: Repairs were completed to the satisfaction of the attending Marine Inspectors. See activities 7771212 and 7898093 for additional information.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 December 2022
Resolved
Replace deck planks in forward compartment, from frames 19-26, stbd side.
Action required: 705 - Other - as specified
Due 30 June 2025
Resolved 21 May 2024
Resolution: Forward compartment re-worked during DD/ISE work.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 December 2022
Resolved
Remove ceiling boards in forward compartment, port side, to allow for further inspection of frames.
Action required: 705 - Other - as specified
Due 31 December 2023
Resolved 21 May 2024
Resolution: Forward compartment carlins and futtocks on stbd side restored during DD/ISE.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 July 2022
Resolved
At each subsequent inspection for certification the MI shall view the vessel afloat and shall conduct inspections of the hull. Clipper bow laminated knee second laminate from stem has come apart. Provide repair proposal and make repairs to satisfaction of MI. 46 CFR 176.25-5
Action required: 705 - Other - as specified
Due 18 July 2022
Resolved 21 May 2024
Resolution: Stem, Bowsprit, Deck, hull planking and surrounding hardware restored as new during DD/ISE.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 July 2022
Resolved
At all inspections special attention shall be paid to insure that guards or protective devices are provided. No guard for rotating machinery on MDE. Install. 46 CFR 176.25-10
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 16 August 2022
Resolution: Guard installed. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2022
Resolved
Individual pumps used for separate spaces must have a light or other visual means to indicate operation. Fwd bilge indicator and mid bilge indicator lights are out. Replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 16 August 2022
Resolution: Fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2022
Resolved
A vessel must be provided with bilge pumps. Mid bilge pump inop. Corrected on the spot. One of two E/R electric bilge pumps inop. Replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 16 August 2022
Resolution: E/R bilge pump replaced. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2022
Resolved
A submersible electric pump may be used provided that a positive shutoff valve is installed. No positive shutoff valves installed on discharge.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 21 May 2024
Resolution: Found sat.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 18 July 2022
Resolved
A complete but simple instructions for the operation of a fixed fire extinguishing system must be located in a conspicuous place where the extinguishing agent cylinders are stored. No instructions provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 16 August 2022
Resolution: Instructions provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2021
Resolved
When the flexible section of a fuel fill pipe is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Bonding wire is not bonded at the top.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 19 August 2021
Resolution: Reattached bonding wire correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2021
Resolved
Spaces containing machinery shall be fitted with adequate ventilators to provide sufficient air for proper operation. Vent piping is loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 19 August 2021
Resolution: Added fastners to secure the vent piping.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 August 2021
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Stbd fwd space bulkhead penetrations not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 30 August 2021
Resolution: sealed the watertight bulkhead penetration.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 August 2021
Resolved
The sidelights of vessels 20 meters or more in length shall be fitted with matte black inboard screens. Screens on vessel lights are not matte black.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 26 August 2021
Resolution: Painted nav light screens matte black.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult
life jackets so the child size life jackets are not
mistaken for adult life jackets. Life jackets onboard
the vessel are stored with sizes mixed together.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 19 August 2021
Resolution: Separated adult and child PFDs and labeled appropriately.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 2 August 2021
Resolved
Prior to departing on a voyage, the passenger count must be communicated verbally or or in writing and available ashore at the vessel's normal berthing location or with a representative of the owner and shall be available to the Coast Guard upon request. No passenger count method established.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 26 August 2021
Resolution: Passenger count mailbox has been placed on the pier.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC licensed technician once every 5 years, after which a Communications Act Safety Radiotelephony Certificate will be issued. Vessel does not have a current radiotelephony certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 30 August 2021
Resolution: provided certificate after FCC licensed technician visited the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2021
Resolved
Bridge-to-bridge radiotelephone station will be inspected on vessels subject to regular inspections pursuant to the requirements of Parts II and II of Title III of the Communications Act. Vessel does not have proof of bridge-to-bridge FCC inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2021
Resolved 9 May 2022
Resolution: Vessel has second radio installed and received a bridge to bridge certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2021
Resolved
Ship stations in maritime service must be licensed by the FCC. Vessel does not have an FCC ship station license.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 19 August 2021
Resolution: Located and displayed the current FCC ship station license.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 July 2021
Resolved
Vessel reported a complete shutdown of the main engine. Vessel directed to make repairs & prove satisfactory operation to USCG. 46 CFR 182.100
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 4 July 2021
Resolved 6 July 2021
Resolution: Found cause to be loose wire connection on fuse for MDE computer. Tightened wire, used locktight, and hung wire so it would not pull on fuse.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 February 2021
Resolved
Vessel down-rigged for dry dock. Re-rig, tune and complete sea trail to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2021
Resolved 14 June 2021
Resolution: Vessel has been re-rigged, tuned and has completed sea trail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2021
Resolved
Vessel re-powered during dry dock. Complete sea trail and prove proper operation of main engine, gauges and auxiliaries to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2021
Resolved 14 June 2021
Resolution: Completed sea trail to prove proper operation of main engine, gauges and auxiliaries; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 August 2020
Resolved
Vessels bilge priming line is wasted, leaking, and in need or replacement. Replace Bilge priming line to the satisfaction of the CGMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2020
Resolution: Inspected new bilge priming line and test ran the bilge system; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 August 2020
Resolved
Vessels fire pump is INOP. Provide and prove proper operation of fire pump with 50 GPM @ 60 psi.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2020
Resolution: Inspected new fire pump installation and test ran; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020
Resolved
Midship compartment - Found permanently mounted extension cord with power strip and multiple items plugged into it. Remove from vessel.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2020
Resolution: Inspected midship compartment, extension cord and surge protector have been removed from the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020
Resolved
Found exposed wiring in midships compartment. Remove or end in an enclosure to the satisfaction of the CGMI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2020
Resolution: Dead end wiring removed from vessel; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020
Resolved
Improperly wired GPS ran from exposed hole in power panel and through an old gauge mount location in the consol. Ensure no opening in the power panel and make penetration to weather deck weather-tight to the satisfaction of the CGMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2020
Resolved 2 September 2020
Resolution: Deficiency cleared to satisfaction of CG marine inspector
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020
Resolved
Found wiring in aft steering not properly secured. Properly mount and secure wiring to the satisfaction of the CGMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2020
Resolved 2 September 2020
Resolution: Deficiency cleared to satisfaction of CG marine inspector
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2018
Resolved 18 September 2018
Resolution: Vessel rep. cleared the AIS deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 August 2018
Resolved
Prove proper operation of the starboard running light
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2018
Resolved 15 August 2018
Lifesaving › Lifebuoys › Serviceable
Issued 10 August 2017
Resolved
Found grab line not serviceable.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 7 September 2017
Resolution: Life ring replaced with all attachments renewed.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 August 2017
Resolved
Non compliance with NVIC 02/16 Sail rigging PMP.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 September 2017
Resolved 7 September 2017
Resolution: Inspected and verified compliance with NVIC 02/16 Sail rigging PMP is current.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 August 2016
Resolved
Provide MMSI and location information on VHF radio.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 13 September 2016
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 August 2016
Resolved
Replace existing trash can with approved metal can.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 13 September 2016
Resolution: Replaced existing trash can with approved metal can.
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 11 August 2016
Resolved
Properly mouse shrouds to prevent unwanted movement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 13 September 2016
Resolution: Properly moused shrouds to prevent unwanted movement.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 August 2016
Resolved
Replace outlet cover on GFCI outlet located on main deck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 13 September 2016
Resolution: Replaced outlet cover on GFCI outlet located on main deck.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 August 2016
Resolved
Provide current safety radio certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2016
Resolved 13 September 2016