← All vessels
AURORA
Passenger (Inspected) · Passenger Ship class · Built 1940s · USCG Northeast District (CGD-NE) · Other hulls named AURORA
AURORA is a 1947 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1993, most recently in October 2025, along with 113 deficiencies and 4 casualty investigations between 2007 and 2023.
Records from 1993 to 2025. Most recent: inspection, 28 October 2025.
- Built
- 1947
- Last inspected
- 28 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 113 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2007–2023
Identity
253584
WDD3330
64735
Flag
UNITED STATES
367129010 (licence lapsed)
Maury page id
psix-64735
Inspections, by type
…with no type recorded8
Years with a record
32 calendar years (1993–2025)
The 58 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)68.0 ft × 17.6 ft × 8.4 ft
Registered tonnagegross 53 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWBERT & WALLACE · THOMASTON ME, UNITED STATES · built 1947
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Net Ton
53 - Regulatory (Subpart C or D), Gross Ton
53 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD3330MMSI 367129010 · expired · compulsorily equipped · granted 21 May 2016, cancelled 15 August 2026
WCW6711MMSI not assigned · expired · compulsorily equipped · granted 17 June 1996, cancelled 19 August 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 58
28 October 2025
Vessel Attendance · Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8260398
11 August 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8207403
24 May 2024
Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7898093
17 August 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7771212
29 June 2023
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7726623
28 June 2023
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7746856
16 December 2022
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7608465
18 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7488469
14 March 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7412323
2 August 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7258219
4 July 2021
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7250688
18 February 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7134694
3 August 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7017368
10 May 2019
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6665152
20 December 2018
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6591242
27 August 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6524367
2 August 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6498745
10 August 2017
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6226971
1 May 2017
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6244794
12 January 2017
Internal Structural Exam · Examination of Repairs · Drydock Exam · Construction Oversight · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6066862
11 August 2016
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5960392
6 August 2016
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 5965852
17 August 2015
Annual Inspection · Administrative Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5205022
25 June 2014
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4910372
5 July 2012
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4359778
29 September 2011
MARPOL Annex VI Survey · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4157324
14 July 2011
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4080956
13 October 2010
Internal Structural Exam · Deficiency Check · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3869155
21 April 2009
Deficiency Check · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3447286
31 July 2008
Deficiency Check · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3274908
15 September 2007
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3059433
27 July 2006
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2726684
23 August 2005
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2465150
22 July 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2435653
21 July 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2434900
14 July 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2426357
11 July 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2422819
23 June 2005
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2400228
3 February 2005
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2278530
8 June 2004
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2088765
18 August 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1876971
8 January 2003
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1724804
16 May 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1616116
11 May 2001
Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1455994
9 March 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1059718
12 July 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 822699
12 June 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1415399
24 May 2000
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1049924
28 March 2000
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1047513
26 May 1999
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1412017
15 April 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1450380
16 June 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1126603
19 June 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 781579
13 June 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 775057
10 June 1996
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1082991
21 June 1995
MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1377409
24 June 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 826207
24 June 1993
Initial Construction-Excluding Oversight · Hull Examination · MARPOL Annex V Examination · Initial Certification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1157473
Deficiency record · 113
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2026
Resolved
An inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails. Replace incorrect topmast shroud pin with the correct shroud pin and clevis pin.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 August 2025
Resolved
Ring buoy grab line is weathered, weakened, wasted. Replace ring buoy.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 August 2025
Resolved
Vessel is missing logs of inspections of the rig in accordiance with the rig and inspection program. Provide copy of logged rig inspection after 30 days.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 11 August 2025
Resolved
All cable and wire must be installed with metal supports
spaced not more than 24 inches apart and must be installed properly. Midship cabin area stbd side light electrical cables were found supported with tape and exposed wiring. Properly install the electrical cable to light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2025
Resolved
Cable and wire must not be installed with sharp bends. Midship cabin area port side cable bundle has sharp bends in the cable.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 August 2025
Resolved
The movement of the vessel shall be under the direction and control of the licensed master. Provide copy of the medical card that accompanies the master's license.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Monitor water ingress for 14 days, and report findings to this office. Establish a bilge log reflecting the gallons per minute of water ingress; maintain and present this log to inspectors during future inspections.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 May 2024
Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the CO2 cylinder storage room. On systems in which the CO2 cylinders are not within the protected space, these instructions must also include a diagram of the system and instructions detailing alternate methods of discharging the system should the manual release or stop valve controls fail to operate. CO2 instructions have been painted over.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge Marine Inspection, as good marine practice. Replace Jib topmast stay turnbuckle with longer 3/4" turnbuckle.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Gammon iron to forestay bolt shall be replaced with a solid bolt with threads outside of flange. Current bolt allows the stay to land on the threads. Include bushings/spacers on either side of the forestay to prevent the stay from sliding on the bolt.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Replace starboard foretopmast shroud turnbuckle. The jib top shall not be flown until this turnbuckle is received and approved by a reviewing MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2024
Resolved
It is intended that all machinery be installed in such a manner to afford protection against personnel injury. Add machinery guard around bilge pump belts in way of the front of the main engine to prevent injury.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Fabricate a well ventilated box to protect the gasoline fire pump on deck. The box should be easily removable and indicate that "NO SMOKING" and "NO SITTING' is allowed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 May 2024
Resolved
For items not covered in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Check fire pump fuel level prior to getting underway at a minimum once a week, while the vessel is in service, to ensure that the fuel tank remains full of good fuel. The results of the check should be logged. Provide this office with the run time of the pump under load on a single tank of fuel.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 June 2023
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage and to effect permanent repairs. Following a collision on June 28th 2023, which ripped the vessel's bowsprit off, Marine Inspectors observed damage in way of the bow, and radiating throughout the vessel as a result of the collision. Vessel is required to undergo a Coast Guard Dry Dock and Internal Structural Examination, and effect permanent repairs to damage that is identified by the attending Marine Inspector prior to returning to service.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 June 2023
Resolved
The design, materials, and construction of masts, posts, yards, booms, bowsprits, and standing rigging on a sailing vessel must be suitable for the intended service. The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Following a collision on June 28th 2023, which ripped the vessel's bowsprit off, Marine Inspectors observed damage in way of the bow, and radiating throughout the vessel as a result of the collision. A rig survey is required prior to the vessel's return to service. Prior to completing the survey, contact this office for approval to proceed, and to orchestrate CG attendance at the survey.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 December 2022
Resolved
Replace deck planks in forward compartment, from frames 19-26, stbd side.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 December 2022
Resolved
Remove ceiling boards in forward compartment, port side, to allow for further inspection of frames.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 July 2022
Resolved
At each subsequent inspection for certification the MI shall view the vessel afloat and shall conduct inspections of the hull. Clipper bow laminated knee second laminate from stem has come apart. Provide repair proposal and make repairs to satisfaction of MI. 46 CFR 176.25-5
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 July 2022
Resolved
At all inspections special attention shall be paid to insure that guards or protective devices are provided. No guard for rotating machinery on MDE. Install. 46 CFR 176.25-10
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2022
Resolved
Individual pumps used for separate spaces must have a light or other visual means to indicate operation. Fwd bilge indicator and mid bilge indicator lights are out. Replace.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2022
Resolved
A vessel must be provided with bilge pumps. Mid bilge pump inop. Corrected on the spot. One of two E/R electric bilge pumps inop. Replace.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2022
Resolved
A submersible electric pump may be used provided that a positive shutoff valve is installed. No positive shutoff valves installed on discharge.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 18 July 2022
Resolved
A complete but simple instructions for the operation of a fixed fire extinguishing system must be located in a conspicuous place where the extinguishing agent cylinders are stored. No instructions provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2021
Resolved
When the flexible section of a fuel fill pipe is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Bonding wire is not bonded at the top.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2021
Resolved
Spaces containing machinery shall be fitted with adequate ventilators to provide sufficient air for proper operation. Vent piping is loose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 August 2021
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Stbd fwd space bulkhead penetrations not watertight.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 August 2021
Resolved
The sidelights of vessels 20 meters or more in length shall be fitted with matte black inboard screens. Screens on vessel lights are not matte black.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult
life jackets so the child size life jackets are not
mistaken for adult life jackets. Life jackets onboard
the vessel are stored with sizes mixed together.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 2 August 2021
Resolved
Prior to departing on a voyage, the passenger count must be communicated verbally or or in writing and available ashore at the vessel's normal berthing location or with a representative of the owner and shall be available to the Coast Guard upon request. No passenger count method established.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC licensed technician once every 5 years, after which a Communications Act Safety Radiotelephony Certificate will be issued. Vessel does not have a current radiotelephony certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2021
Resolved
Bridge-to-bridge radiotelephone station will be inspected on vessels subject to regular inspections pursuant to the requirements of Parts II and II of Title III of the Communications Act. Vessel does not have proof of bridge-to-bridge FCC inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2021
Resolved
Ship stations in maritime service must be licensed by the FCC. Vessel does not have an FCC ship station license.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 July 2021
Resolved
Vessel reported a complete shutdown of the main engine. Vessel directed to make repairs & prove satisfactory operation to USCG. 46 CFR 182.100
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 February 2021
Resolved
Vessel down-rigged for dry dock. Re-rig, tune and complete sea trail to the satisfaction of the attending Coast Guard Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2021
Resolved
Vessel re-powered during dry dock. Complete sea trail and prove proper operation of main engine, gauges and auxiliaries to the satisfaction of the attending Coast Guard Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 August 2020
Resolved
Vessels bilge priming line is wasted, leaking, and in need or replacement. Replace Bilge priming line to the satisfaction of the CGMI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 August 2020
Resolved
Vessels fire pump is INOP. Provide and prove proper operation of fire pump with 50 GPM @ 60 psi.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020
Resolved
Midship compartment - Found permanently mounted extension cord with power strip and multiple items plugged into it. Remove from vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020
Resolved
Found exposed wiring in midships compartment. Remove or end in an enclosure to the satisfaction of the CGMI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020
Resolved
Improperly wired GPS ran from exposed hole in power panel and through an old gauge mount location in the consol. Ensure no opening in the power panel and make penetration to weather deck weather-tight to the satisfaction of the CGMI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020
Resolved
Found wiring in aft steering not properly secured. Properly mount and secure wiring to the satisfaction of the CGMI.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 August 2018
Resolved
Prove proper operation of the starboard running light
Lifesaving › Lifebuoys › Serviceable
Issued 10 August 2017
Resolved
Found grab line not serviceable.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 August 2017
Resolved
Non compliance with NVIC 02/16 Sail rigging PMP.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 August 2016
Resolved
Provide MMSI and location information on VHF radio.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 August 2016
Resolved
Replace existing trash can with approved metal can.
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 11 August 2016
Resolved
Properly mouse shrouds to prevent unwanted movement.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 August 2016
Resolved
Replace outlet cover on GFCI outlet located on main deck.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 August 2016
Resolved
Provide current safety radio certificate.
Navigation › Piloting/Steering › Marine Charts
Issued 5 July 2012
Resolved
Provide current up to date charts.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 5 July 2012
Resolved
Renew main engine cooling pump inlet and discharge hoses.
Electrical › Electrical Distribution System (service) › Conductor
Issued 5 July 2012
Resolved
Properly support loose wiring in lazzarette as discussed.
Construction/Loadline › Structures › Superstructure
Issued 21 April 2009
Resolved
Provide new boom for main mast.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 21 April 2009
Resolved
Resecure rail stanchion IWO operating station, stbd side
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 April 2009
Resolved
Provide functioning light for compass.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 April 2009
Resolved
Provide new waterlight battery.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 April 2009
Resolved
Provide ground for both fuel tanks.
Fire Fighting › Fire Pumps › Arrangement
Issued 21 April 2009
Resolved
Provide support for fire manifold piping (per supports prior to fire pump overhaul).
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 21 April 2009
Resolved
Provide marking for child PFD shelves in main hold, port side.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 21 April 2009
Resolved
Provide marking for CO2 bottle stowage IAW 46 CFR part 185.
Stability › Watertight Integrity › General
Issued 20 April 2009
Resolved
Prior to credit drydock, seal wire runs through water tight bulkheads and provide gasket material around acess hatches to steering compartment and forepeak.
Construction/Loadline › Hull › Keel
Issued 20 April 2009
Resolved
Prior to credit drydock, provide satisfactory operational/underway test with marine inspector to witness keelson repair area and framing in forward hold.
Engineering › Fuel Oil Service System › Hose
Issued 31 July 2008
Resolved
Provide approved SAE1942 hose and attachments for fuel vent runs using flex hose
Engineering › Fuel Oil Service System › Gauge
Issued 31 July 2008
Resolved
Provide for proper means to determine amount of fuel in fuel tank
Engineering › Sea-water System (primary cooling) › Valve
Issued 31 July 2008
Resolved
Provide operational valve handles for all overboard discharge/intake valves in engine room
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 31 July 2008
Resolved
Repair/replace broken glass cover on fixed firefighting system emergency pull
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 July 2008
Resolved
Prior to carrying passengers properly attach all ladders
Fire Fighting › Fire Pumps › Power Source
Issued 31 July 2008
Resolved
Prior to sailing/carrying passengers provide required power driven fire and bilge pump. Prove proper operation to attending USCG Marine Inspector
Lifesaving › Buoyant Apparatus › Serviceable
Issued 31 July 2008
Resolved
Repair or replace both Bouyant Apparatus NLT 14Aug2008
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 31 July 2008
Resolved
Provide proper rescue platform and complete MOB drills
Engineering › Bilge Water Management System › Piping
Issued 31 July 2008
Resolved
Remove temporary bilge pump and hose/bucket
Engineering › Fuel Oil Service System › Hose
Issued 31 July 2008
Resolved
Ensure vent lines for fuel tanks are installed w/ an upward gradient manner
Communications › Alarms/Indicators › High Water Alarm
Issued 31 July 2008
Resolved
Provide visual high water alarm at the operating station
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 27 July 2006
Resolved
Provide FCC Safety Radio Telephone Inspection and Certificate.
Documentation › Certificates/Documents › Stability Letter
Issued 27 July 2006
Resolved
Prove vessel's current ballast condition is in accordance with the stability letter dated 22 June 1993 or perform a new stability test. Until complete, vessel is restricted to waters of Narragansett Bay inside the line of demarcation (protected).
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 July 2006
Resolved
Provide copy of fixed CO2 servicing certificate.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 July 2006
Resolved
Replace expired items in first aid kit.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 27 July 2006
Resolved
Prior to operating outside of 1NM offshore of land , renew and install weak links for bouyant apparatus.
Construction/Loadline › Structures › Superstructure
Issued 18 May 2005
Resolved
Provide rigging survey from qualified rigger or marine surveyor.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 8 June 2004
Resolved
Install a double clamp on the hosing from the fuel tank vent
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 June 2004
Resolved
Replace the reflective tape on 48 life jackets that were rejected by the inspector, the vessel is restricted to carrying 60 passengers till resolved
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 8 June 2004
Resolved
Replace the grounding wire on the fuel fills to the proper size
Engineering › Bilge Water Management System › Manifold
Issued 18 August 2003
Resolved
Ships bilge manifiold valve for the forepeak bilge suction inop. Prove proper operation of system prior to carrying passengers.
Lifesaving › Lifebuoys
Issued 18 August 2003
Resolved
Replace retro tape on life rings. LEGACY COMPONENT DESC: retro tape
Engineering › Bilge Water Management System
Issued 18 August 2003
Resolved
replace wasted sea strainer for bigle suction in forward fish hold. LEGACY COMPONENT DESC: Strainer
Construction/Loadline › Markings
Issued 8 January 2003
Resolved
Spreaders for main and fore topmasts must be replaced to run further aft and line up for proper lead-to-chain plate angle. Topsails are not permitted to be flown with passengers prior to repair.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 May 2002
Resolved
Provide contract and annual activity rport from consortium.
Engineering › Bilge Water Management System
Issued 16 May 2002
Resolved
Provide visual indication at the operating station for each automatic bilge pump. LEGACY COMPONENT DESC: Pump
Fire Fighting › Nozzles
Issued 16 May 2002
Resolved
Provide nozzle for fire hose that allows 1/2" stream+ fog.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 May 2002
Resolved
Complete MOB drill.
Documentation › Markings/Placards
Issued 16 May 2002
Resolved
Label "No passengers beyond this point" at the bow sprit. LEGACY COMPONENT DESC: Injury Placard
Navigation › Piloting/Steering
Issued 16 May 2002
Resolved
During vessels next hull exam rebuild or fabricate spokes for helm so that they fit tightly and are sound in their hub assembly. LEGACY COMPONENT DESC: Steering helm
Documentation › Markings/Placards
Issued 16 May 2002
Resolved
Label F/O pulls. LEGACY COMPONENT DESC: emegency fuel shutoffs
Unknown
Issued 11 May 2001
Resolved
VHF RADIO TRASMISSION WEAK (1WATT), REPAIR OR REPLACE. VESSEL RESTRICTED TO1000 FT FROM SHORE.
Unknown
Issued 11 May 2001
Resolved
OBTAIN/MOUNT EMERGENCY BROADCAST PLACARD IN VICINITY OF VHF RADIO.
Unknown
Issued 11 May 2001
Resolved
STENCIL ALL LIFEJACKET STORAGE AREAS WITH NUMBER AND TYPE (ADULT/CHILDREN)._x001C_ _x001C_ _x001C_
Unknown
Issued 11 May 2001
Resolved
NO LIGHT LIST OR COAST PILOT ONBOARD, OR EQUIVILANT.
Unknown
Issued 12 June 2000
Resolved
MAKE PROPER REPAIRS TO LIFE FLOAT WHERE TWO DEEP HOLES HAVE BEEN MADE.
Unknown
Issued 12 June 2000
Resolved
INSTALL VISUAL INDICATOR FOR AUTOMATIC BILGE PUMP.
Unknown
Issued 26 May 1999
Resolved
INSTALL AN AIRTIGHT BULKHEAD IWO AFT ENGINE ROOM ENTRANCE IN ORDER TO CREATE A SMALLER SPACE TO COMPLY WITH THE FIXED FIRE SUPRESSION TOTAL FLOODING REQUIREMENTS IN ENGINE ROOM.
Unknown
Issued 26 May 1999
Resolved
INSTALL FIRE DETECTION SYSTEM IN ENGINE ROOM.
Unknown
Issued 26 May 1999
Resolved
PROVIDE PROOF OF VALID ANNUAL STICKER FOR THE VESSEL'S CERTIFICATE OF DOCUMENTATION.
Unknown
Issued 26 May 1999
Resolved
PROVIDE ON BOARD A VALID RADIO SAFETY CERTIFICATE.
Documentation
Issued 10 June 1996
Resolved
PROVIDE AN UPDATED DRUG PROGRAM CREW ENROLLMENT FORM.
Documentation
Issued 10 June 1996
Resolved
POST A 1-800 NUMBER IN AN AREA FREQUENTED BY THE CREW.
Documentation
Issued 10 June 1996
Resolved
PROVIDE PROOF OF UPDATED VSL DOCUMENTATION DUE TO CHANGE IN OWNERSHIP.
Documentation
Issued 10 June 1996
Resolved
PROVIDE PROOF OF CURRENT RADIO STATION FCC LICENSE.
Construction/Loadline
Issued 10 June 1996
Resolved
INSTALL A BELT GUARD FOR THE MAIN ENGINE ATTACHED BILGE PUMP.
Lifesaving
Issued 10 June 1996
Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Lifesaving
Issued 10 June 1996
Resolved
PROVIDE A FIRST AID KIT IN ACCORDANCE WITH 46CFR160.041-5.
Documentation
Issued 10 June 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Casualty record · 4
15 September 2007Routine · role: Involved in a Marine Casualty · activity 3059433
25 June 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4910372
6 August 2016Routine · role: Involved in a Marine Casualty · 1 injured · activity 5965852
28 June 2023Routine · role: Involved in a Marine Casualty · activity 7746856
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.