MAURY USCG vessel records
← All vessels

OLUF MAERSK

OLUF MAERSK is a 2003 freight ship. The Coast Guard has recorded 29 inspections since 2016, most recently in December 2025, along with 10 deficiencies and 6 operational controls.

Records from 2016 to 2025. Most recent: inspection, 19 December 2025.

Built
2003
Last inspected
19 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 December 2025
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9251626
650228
Flag
DENMARK
Maury page id
psix-650228

Documentation record

Tonnage as PSIX records it34202 - Convention (Subpart B), Gross Ton
41026 - Dead Weight, Metric Ton
56983 - Displacement, Metric Ton
15054 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

29 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; 6 operational controls with the dates imposed and removed; 1 vessel inspected with it, by name and date; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

B-320 Freight Barge · MISLE 78470 · 18 March 2016 · activity 5836198

Inspection history · 29

19 December 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8284619
29 April 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8123245
13 September 2024 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7999934
15 April 2024 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7895334
4 March 2024 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7873538
23 December 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7841390
3 October 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7802782
23 May 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7694537
8 October 2022 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7571915
17 February 2022 Ballast Water Examination · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7394760
7 February 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7391964
16 June 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7226797
14 October 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7076802
3 March 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6919436
17 July 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6752915
12 February 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6624613
3 July 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6465033
3 December 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6316996
3 October 2017 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6280473
3 October 2017 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6281257
25 September 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6274828
9 May 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6141898
23 May 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5884472
18 March 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5836198
16 March 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5834209
16 March 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5834261
15 March 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5834044
15 March 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5835801
14 March 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5833186

Deficiency record · 10

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 September 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2024
Resolved 22 September 2024
Resolution: Vessel receieved pyro on board.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 23 December 2023 Resolved
Machinery and associated piping systems shall be adequate for intended service. Discharge valve on #1 HFO purifier is secured to adjacent piping with bailing wire in order to ensure that valve handle engages fuel pup cutoff contact switch due to play in the valve handle assembly. 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 December 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 23 December 2023 Resolved
Machinery and associated piping system shall be adequate for inteded service. Ballast Water control valve actuator was dissassembled and valve was being temporarily operated with an adjustable wrench held in place by line. 74 SOLAS (2004 Consolidated) II-1/26.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 April 2024
Resolution: Received documentation approving repairs, see documents for further information.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 23 December 2023 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. The above technical deficiencies, which were unreported to the company and did not have a clearly proposed corrective action, indicate a failure or lack of effective implementation of the ISM Code related to onboard maintenance protocols. An internal audit of maintenance procedures is to be conducted and corrective actions implemented within three months. 74 SOLAS (2020 Consolidated) IX/3.1; ISM Code 10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 March 2024
Resolved 4 March 2024
Resolution: Received report from the internal audit. See attached for further information.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2019 Resolved
The Emergency generator was actively leaking fuel oil from a sample port just before the generators fuel filters at a rate or 60 drips per min while the system was running. Crew replaced the O-Ring while PSC was onboard.
Action required: 10 - Deficiency Rectified
Resolved 17 July 2019
Resolution: Crew replaced O-Ring while PSC was onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 July 2018 Resolved
99101- the condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. In one of the segments of the underdeck passageway there was an excessive accumulation of water measuring approximately 03 inches deep along the entire length of the passageway. 74 SOLAS (14) I/11 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 July 2018
Resolved 3 July 2018
Resolution: Class report attached in documents, steam line leak in area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 July 2018 Resolved
09210- the machinery shall be so installed and protected as to reduce to a minimum any daners to persons on board with due regard being paid to moving parts, hot surfaces, and other hazards. The design shall have regard to materials used in construction the purpose for which the equipment is intended, the working conditions to which it will be subjected and the enviormental conditions on board. Box fans were placed near generators to cool them down. 74SOLAS(04) II-1/26 (50ac)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2018
Resolved 3 July 2018
Resolution: class report is attached in documents.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 July 2018 Resolved
03199- the ring, lines, and letters shall be painted in white or yellow on a dark background or in black on a light background. the ring and load lines were not painted and the deckline was painted blue on a blue background. 66ICLL(88 proto) I/8 (40c)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 December 2018
Resolution: Vessel supplied photo showing correction
Engineering › Diesel Engine (auxiliary) › Blower, Centrifugal
Issued 3 October 2017 Resolved
#2 Scavenge air blower failed
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2017
Resolved 3 October 2017
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 March 2016 Resolved
All ships 3000 GT and upwards shall have the following functional radars: 9GHz and a 3 Ghz, or 02 9Ghz radars. Vessel reported inoperable secondary radar, unable to fix in port due to lack of parts. 74 SOLAS (14) V/19.2.3.2, 19.2.7.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 May 2016
Resolution: On 23MAY16 Sector Delaware Bay received class/tech report attesting to repairs to secondary marine radar. 00 Deficiencies remain outstanding.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.