MAURY USCG vessel records Sign in
← All vessels

AUCKLAND SPIRIT

AUCKLAND SPIRIT is a 2003 freight ship. The Coast Guard has recorded 24 inspections since 2003, most recently in February 2021, along with 9 deficiencies and 3 operational controls.

Records from 2003 to 2021. Most recent: inspection, 12 February 2021.

Built
2003
Last inspected
12 February 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9268083 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
650893
Flag
MARSHALL ISLANDS
—
Maury page id
psix-650893

Inspections, by type

…with no type recorded4
Years with a record 12 calendar years (2003–2021)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19883 - Convention (Subpart B), Gross Ton
10780 - Convention (Subpart B), Net Ton
32262 - Dead Weight, Ton
249946 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

12 February 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7140161
28 January 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7128227
21 January 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7128302
3 July 2019 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6734969
25 February 2019 ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6625813
21 February 2019 COE-Administrative
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6630180
9 February 2017 ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6085604
6 February 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6083543
14 October 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5742413
3 May 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4292388
18 December 2009 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3648648
17 November 2008 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3364647
4 May 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3198294
8 February 2008 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3141004
30 March 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2898443
25 January 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · ILO-147 Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2860477
25 January 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2861425
9 August 2006 ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2735384
16 November 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2536026
27 July 2005 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2439891
26 May 2004 Deficiency Check · MTSA/ISPS Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2079155
17 October 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1930584
16 October 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1930135
16 October 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1933920

Deficiency record · 9

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 January 2021 Resolved
Bulk carriers shall comply with the maintenance requirements provided in the standards for owner’s inspection and maintenance of bulk carrier hatch covers adopted by the organization by resolution MSC.169 (79). PSCO noted deficient maintenance items such as cleat gaskets frozen, hydraulic leak in the forward No. 2 cargo hold, and sealing arrangements of cargo hold No. 3.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2021
Resolved 11 February 2021
Resolution: Recieved class report on 11FEB2021 clearing def, uploaded in docs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 28 January 2021 Resolved
Adequate power ventilation shall be provided in enclosed cargo spaces. PSCO noted that the ventilation dog and dampers were frozen as well as covers inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2021
Resolved 11 February 2021
Resolution: Recieved class report on 11FEB2021 clearing def, uploaded in docs.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 January 2021 Resolved
The sitting and installation of accumulator batteries which provided as reserve source of energy shall be such as to ensure reasonable safety. PSCO noted batteries were not seated and able to shift easily.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2021
Resolved 28 January 2021
Resolution: 10C
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 January 2021 Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker). PSCO noted flammable liquids in the BOSN locker were not properly stowed in a space protected by a fixed extinguishing system. PSCO also noted a hole in the paint locker door rendering it not vapor tight.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2021
Resolved 11 February 2021
Resolution: Recieved class report on 11FEB2021 clearing def, uploaded in docs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 28 January 2021 Resolved
Ventilator openings shall be provided with weather tight closing appliances of steel or other equivalent material. PSCO noted ventilators cannot close successfully due to excess corrosion on cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2021
Resolved 11 February 2021
Resolution: Recieved class report on 11FEB2021 clearing def, uploaded in docs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 January 2021 Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the organization. PSCO noted that fire extinguishers and other equipment were not maintained and should be carried out in accordance with MSC. Circ.1432.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2021
Resolved 11 February 2021
Resolution: Recieved class report on 11FEB2021 clearing def, uploaded in docs.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 9 February 2017 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices with a stored energy capacility of at least three consecutive starts. A second source of energy shall be provided for an additional three starts. Second batter bank was incapable of starting emergency generator. Solas (2004 Cons) Ch. II-1 Reg. 44.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2017
Resolution: Recieved class report attesting to batteries for number 2 battery bank on emergency generator being replaced. See documents for details.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 18 December 2009 Resolved
0710 Multiple self-closing doors, designated by ship's fire plan, have permanently installed hold-back devices. These doors include, but are not limited to, both steering gear-engine room accesses, CO2 bottle room, and door directly outside ship's office. Doors will not properly prevent the spread of fire in the held back position. SOLAS (04 cons) Ch. II-2 reg.9.4.2.2 70ac
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2010
Resolution: Vessel removed all permanetly installed hold-back devices on all doors designated as self-closing, class A doors by the FIre control plan.
Engineering › Shafting/Propeller Arrangements
Issued 17 October 2003 Resolved
Vsl propulsion propeller has two bent blades. # 1 the bent in way of the tip, over 130 mm. Blade # 5 bent over approx 400 mm x 300 mm along trailing edge. Repair the following to the satisfaction of the issuing authority of the Safety Construction Cert. Condition of class was issued, by ABS.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 5 January 2004
Resolution: Dive Solutions performed an inspection of the propellor. No damage noticed or stress cracks. Propellor in good condition. [name withheld] states that the blades are straight, no mechanical damage noticed, or stress cracks.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.