← All vessels
AUCKLAND SPIRIT
AUCKLAND SPIRIT is a 2003 freight ship. The Coast Guard has recorded 24 inspections since 2003, most recently in February 2021, along with 9 deficiencies and 3 operational controls.
Records from 2003 to 2021. Most recent: inspection, 12 February 2021.
- Built
- 2003
- Last inspected
- 12 February 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9268083 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7IP8
650893
Flag
MARSHALL ISLANDS
—
Maury page id
psix-650893
Inspections, by type
…with no type recorded4
Years with a record
12 calendar years (2003–2021)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it19883 - Convention (Subpart B), Gross Ton
10780 - Convention (Subpart B), Net Ton
32262 - Dead Weight, Ton
249946 - Displacement, Ton
10780 - Convention (Subpart B), Net Ton
32262 - Dead Weight, Ton
249946 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
12 February 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7140161
28 January 2021
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7128227
21 January 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7128302
3 July 2019
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6734969
25 February 2019
ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6625813
21 February 2019
COE-Administrative
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6630180
9 February 2017
ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6085604
6 February 2017
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6083543
14 October 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5742413
3 May 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4292388
18 December 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3648648
17 November 2008
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3364647
4 May 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3198294
8 February 2008
Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3141004
30 March 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2898443
25 January 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · ILO-147 Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2860477
25 January 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2861425
9 August 2006
ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2735384
16 November 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2536026
27 July 2005
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2439891
26 May 2004
Deficiency Check · MTSA/ISPS Verification
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2079155
17 October 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1930584
16 October 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1930135
16 October 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1933920
Deficiency record · 9
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 January 2021
Resolved
Bulk carriers shall comply with the maintenance requirements provided in the standards for owner’s inspection and maintenance of bulk carrier hatch covers adopted by the organization by resolution MSC.169 (79). PSCO noted deficient maintenance items such as cleat gaskets frozen, hydraulic leak in the forward No. 2 cargo hold, and sealing arrangements of cargo hold No. 3.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 28 January 2021
Resolved
Adequate power ventilation shall be provided in enclosed cargo spaces. PSCO noted that the ventilation dog and dampers were frozen as well as covers inoperable.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 January 2021
Resolved
The sitting and installation of accumulator batteries which provided as reserve source of energy shall be such as to ensure reasonable safety. PSCO noted batteries were not seated and able to shift easily.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 January 2021
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker). PSCO noted flammable liquids in the BOSN locker were not properly stowed in a space protected by a fixed extinguishing system. PSCO also noted a hole in the paint locker door rendering it not vapor tight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 28 January 2021
Resolved
Ventilator openings shall be provided with weather tight closing appliances of steel or other equivalent material. PSCO noted ventilators cannot close successfully due to excess corrosion on cover.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 January 2021
Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the organization. PSCO noted that fire extinguishers and other equipment were not maintained and should be carried out in accordance with MSC. Circ.1432.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 9 February 2017
Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices with a stored energy capacility of at least three consecutive starts. A second source of energy shall be provided for an additional three starts. Second batter bank was incapable of starting emergency generator. Solas (2004 Cons) Ch. II-1 Reg. 44.2
Fire Fighting › Structural - A Class Divisions › Doors
Issued 18 December 2009
Resolved
0710 Multiple self-closing doors, designated by ship's fire plan, have permanently installed hold-back devices. These doors include, but are not limited to, both steering gear-engine room accesses, CO2 bottle room, and door directly outside ship's office. Doors will not properly prevent the spread of fire in the held back position. SOLAS (04 cons) Ch. II-2 reg.9.4.2.2 70ac
Engineering › Shafting/Propeller Arrangements
Issued 17 October 2003
Resolved
Vsl propulsion propeller has two bent blades. # 1 the bent in way of the tip, over 130 mm. Blade # 5 bent over approx 400 mm x 300 mm along trailing edge. Repair the following to the satisfaction of the issuing authority of the Safety Construction Cert. Condition of class was issued, by ABS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.