NEW FRIENDSHIP is a 2003 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in February 2019, along with 6 deficiencies and 1 operational control.
Records from 2016 to 2019. Most recent: inspection, 10 February 2019.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it58088 - Convention (Subpart B), Gross Ton 30727 - Convention (Subpart B), Net Ton 122172 - Displacement, Ton 104801 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 10 February 2019Resolved
Every Ship of 400 gross tonnage and above and every ship which is certified to carry 15 persons or more shall carry a garbage management plan which the crew shall follow. Crew not following garbage management plan; paint cans, cleaning agents, oil containers,and other flammable products stowed in engine room under lube oil setteling tank for generators.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2019
Resolved 10 February 2019
Resolution: Crew removed and stowed iteam IAW garbage management plan.
Lifesaving › Inflatable Liferafts › Servicing
Issued 25 April 2016Resolved
All life saving appliances shall be ready for immediate use. All liferafts were absent due to servicing. SOLAS (14) III/20.2 Action Taken: 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2016
Resolution: Liferafts are serviced and installed.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 25 April 2016Resolved
Vapor connection flange face must have a permanent stud projecting outward. Required studs were missing or deteriorated to aft port and aft/fwd stbd vapor connection flange face piece. 46CFR39.2001(i) Action taken: 50c
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 18 May 2016
Resolution: Corrected all 4 installed and 2 spare connection flanges.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 25 April 2016Resolved
Each tankship must be fitted with a pressure-sensing device. Vessel's crew was unable to prove operation installed oxygen/vapor pressure monitoring alarm system. 46CFR39.2013 ACTION TAKEN: 50c
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 18 May 2016
Resolution: Tested high/low pressure devices; ALL SAT.
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 25 April 2016Resolved
Vessel did not have the required certification attesting that the installed vapor control system meets 46 CFR Part 39. 46CFR39.1015 ACTION TAKEN: 50c
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 18 May 2016
Resolution: Reviewed the class approval letter; ALL SAT.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 25 April 2016Resolved
Vessels fitted with vapor control systems must have transfer procedures that contain a description of the vapor collection system. The description of the VCS did not exist as prescribed. 33CFR155.750(d) ACTION TAKEN: 50c
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 18 May 2016
Resolution: Reviewed the vapor portion of the transfer procedures; ALL SAT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.