PINTAIL is a 1948 freight ship. The Coast Guard has recorded 56 inspections since 1993, most recently in January 2026, along with 99 deficiencies.

Records from 1993 to 2026. Most recent: inspection, 27 January 2026.

Built
1948
Last inspected
27 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP4267
Flag
UNITED STATES
367717390
Maury page id
psix-65140

Inspections, by type

…with no type recorded5
Years with a record 27 calendar years (1993–2026)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)69.1 ft × 24.1 ft × 5.0 ft
Registered tonnagegross 91 / net 80
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWELDIT TANK & STEEL CO · BELLINGHAM, WA, UNITED STATES · built 1948
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFRIDAY HARBOR, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
80 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP4267MMSI 367717390 · active · compulsorily equipped · granted 13 February 2024, expires 13 February 2034
WDI6312MMSI 367717390 · cancelled · compulsorily equipped · granted 25 February 2016, cancelled 9 February 2024
WDF5177MMSI 367460260 · expired · compulsorily equipped · granted 9 July 2010, cancelled 12 September 2020
WBG6184MMSI not assigned · expired · voluntarily equipped · granted 14 May 1997, cancelled 29 July 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 56

27 January 2026 Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8302588
24 March 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8098675
29 October 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8026301
8 March 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7883169
6 October 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7804632
21 September 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7796094
4 May 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7684489
10 June 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7476632
15 October 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7317465
14 May 2021 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7196983
26 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6987955
7 October 2019 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6826622
9 July 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6743851
4 March 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6636217
15 March 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6372210
12 March 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6370793
20 February 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6358092
2 October 2017 Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6279783
24 March 2017 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6108874
19 January 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6160683
28 December 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6063244
21 September 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6006667
11 March 2016 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5828782
20 November 2015 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5769087
20 December 2011 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4212041
21 December 2009 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3653502
7 December 2009 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3645910
30 January 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3416814
26 February 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3153809
15 January 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3131445
9 April 2007 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2904325
13 March 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2888661
12 December 2005 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2550520
16 December 2004 Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2260877
17 November 2004 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2243153
5 February 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2001103
4 April 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1373411
28 April 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1472690
1 July 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1091998
4 May 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395178
23 February 1999 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1365071
4 May 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470442
4 December 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1112640
2 May 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383528
1 October 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 833424
2 May 1996 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1390250
4 April 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404129
29 August 1995 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1191731
20 July 1995 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 881477
15 May 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1235762
3 May 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1377399
9 December 1994 Excursion Permit
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 834250
19 August 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 868800
3 May 1994 Plan Review "T" Boat · Inclining Experiment · Hull Examination · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1165237
24 July 1993 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 685532
20 July 1993 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 144576

Deficiency record · 99

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 March 2025 Resolved
Each ring life buoy on a vessel must: Be approved in accordance with 160.050 in subchaper Q of this chapter, or other standard specified b the COmmandant, including but not limited to, approval series 160.150. Vessel's ring life buoy has hole approximately 1 inchin in diameter allowing water intrusion. 46CFR180.70(b)(1)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2025
Resolved 24 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 June 2022 Resolved
Life floats and buoyant apparatus, together with their oars and paddles, shall be conspicuously marked with the vessel's name. Paddles are not marked with the vessels name. 46 CFR 185.30-6
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 13 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 June 2022 Resolved
The float-free link required by § 180.130(a)(1) must be certified to meet § 160.073 (requires inclusion of tag). Vessels float free link tag was missing. 46 CFR 180.137
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2022
Resolved 13 July 2022
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 October 2021 Resolved
Crack in weld seam where bilge turn meets the fwd most bulkhead in forepeak void on PORT side, affecting structural integrity and seaworthiness of vessel. Vessel approved for temporary repair via rewelded seam incorporating drill stops, but required to implement permanent crop and renew repair during haul out for DDX credit in Oct/Nov 2021.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 November 2021
Resolved 31 October 2021
Resolution: Permanent repair coducted at DDX.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 March 2019 Resolved
The heating and galley LPG system was not installed IAW applicable standards, nor did it go through plan approval. The system does not have cutoff valves in proper locations, and it does not utilize proper hoses. POC has removed all sources of shipboard LPG from vessel. Vessel will not be allowed to utilize system as is until undergoing proper plan review.
Action required: 705 - Other - as specified
Due 20 March 2019
Resolved 20 March 2019
Resolution: Operator removed propane tanks from the vessel prior to the end of inspection. It was clearly stated to operator that propane system is not to be used until plans have been submitted and approved.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 March 2019 Resolved
Buoyant apparatus is missing paddle; two required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 10 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 March 2019 Resolved
Light on ring buoy assembly on starbard bridge wing is missing latch pin and watertight gasket. Must repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2019
Resolved 10 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 March 2019 Resolved
Stern light was extinguished upon inspection; bulb was replaced on the spot. Sat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 March 2019
Resolved 10 April 2019
Resolution: POC replaced bulb.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 24 March 2017 Resolved
Replace light on life float - 46CFR180.15-1(a) - No night ops prior to correction.
Action required: 705 - Other - as specified
Resolved 18 April 2017
Resolution: New approved light float installed.
Engineering › Fuel Oil Service System › Valve, Solenoid
Issued 24 March 2017 Resolved
Install second means to shut-off fuel supply - 46CFR182.20-40(b)(3) - 14 days.
Action required: 705 - Other - as specified
Due 8 April 2017
Resolved 18 April 2017
Resolution: Installed solenoid valve.
Construction/Loadline › Hull › Bottom Plating
Issued 20 November 2015 Resolved
Repair starboard rose box IWO machinery space IAW 46CFR177.100
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 30 November 2015
Resolution: Cropped and renewed to original condition.
Construction/Loadline › Hull › Hull Plating
Issued 20 November 2015 Resolved
Repair pinhole wastage on starboard IWO of bilge overboard IAW 46CFR177.100
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 30 November 2015
Resolution: Insert of appropriate size fitted into stern.
Construction/Loadline › Hull › Girder
Issued 20 November 2015 Resolved
Repair required for port side girders near steering gear IAW 46CFR177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 30 November 2015
Resolution: Repaired to maintain structural integrity.
Construction/Loadline › Hull › Bottom Plating
Issued 20 December 2011 Resolved
1. Cracked in forward rake, 3rd to 4th transverse frames aft just inboard of 2nd long 2. Cropped out sweage pipe just outboard of port rudder post.
Action required: 705 - Other - as specified
Resolved 20 December 2011
Resolution: 1. 18" X 18" insert completed/tested 2. 18" X 18" insert completed/tested
Lifesaving › Lifefloat › Float-free Link
Issued 21 December 2009 Resolved
Procure and properly install lifefloat float free link in accordance with 46 CFR 180.130.
Due 29 December 2009
Resolved 30 December 2009
Engineering › Fuel Oil Service System › Filter
Issued 21 December 2009 Resolved
Properly install fuel filter flame impingement bowl in accordance with 46 CFR 182.455 (b) 6.
Due 29 December 2009
Resolved 30 December 2009
Documentation › Certificates/Documents › FCC SSL
Issued 21 December 2009 Resolved
Obtain valid FCC station license, Safety Radio Certificate, and Operators Permit in accordance with 46 CFR 184.502.
Due 29 December 2009
Resolved 30 December 2009
Resolution: Vessel has submitted paperwork to FCC to obtain required FCC documents.
Lifesaving › Lifefloat › Float-free Link
Issued 12 February 2009 Resolved
2 requirements included : #1 on 835--Procure and install proper size weak-link on lifefloat. #2 on 835--Reroute painter to permit proper operation of weak-link. Existing weak-link is rated for larger size float and painter is routed in a manner to cause the line to pull against itself rather than the weak-link. As an interim measure, weak link was disconnected to allow assembly to float-free.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 20 February 2009
Resolution: O/O procured and installed proper weak-link. Painter was routed correctly and reattached to allow proper float-free arrangement.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 January 2009 Resolved
Provide proof of current certificate of documentation. Document onboard expired.
Action required: 705 - Other - as specified
Due 14 February 2009
Resolved 2 February 2009
Resolution: Owner provided proof of current document.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 30 January 2009 Resolved
Stbd r/g directional control cylinder mount missing 3 of 4 bolts. O/O installed new bolts/lockwashers during inspection; item was not listed on 835, but was included for tracking purposes only.
Action required: 705 - Other - as specified
Resolved 30 January 2009
Resolution: Prior to end of inspection, Operator reattached cylinder with new bolts/lockwashers. Tested sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 January 2008 Resolved
Renew expired items in first aid kit.
Due 15 February 2008
Resolved 25 February 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 15 January 2008 Resolved
Remove unused wires from the engine room.
Due 15 February 2008
Resolved 25 February 2008
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 15 January 2008 Resolved
Prove proper operation of starboard engine tachometer.
Due 15 February 2008
Resolved 25 February 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 January 2008 Resolved
Provide guard for rotating machinery on both engines and generator.
Due 15 February 2008
Resolved 25 February 2008
Fire Fighting › Fire Hoses › Number
Issued 15 January 2008 Resolved
Provide approved 50 ft fire hose to be kept onboard the vessel.
Due 15 January 2008
Resolved 25 February 2008
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 15 January 2008 Resolved
Provide emergency broadcast placard.
Due 15 February 2008
Resolved 25 February 2008
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 January 2008 Resolved
Provide compass deviation table.
Due 15 February 2008
Resolved 25 February 2008
Documentation › Certificates/Documents › FCC SSL
Issued 15 January 2008 Resolved
Renew expired radio station license.
Due 15 February 2008
Resolved 6 March 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 15 January 2008 Resolved
Provide lifejacket donning placard.
Due 15 February 2008
Resolved 25 February 2008
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 15 January 2008 Resolved
Provide emergency instructions as required by 46 CFR 185.512.
Due 15 February 2008
Resolved 6 March 2008
Personnel › Training › First Aid/CPR
Issued 15 January 2008 Resolved
Provide renewed Red Cross first aid/CPR card.
Due 15 February 2008
Resolved 25 February 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 January 2008 Resolved
Provide junction boxes for wires joined by wire nuts on the bridge.
Due 15 February 2008
Resolved 25 February 2008
Electrical › Electric Supply System (service) › Cable
Issued 15 January 2008 Resolved
Provide means to shut down both engines from the operating station.
Due 15 February 2008
Resolved 6 March 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 January 2008 Resolved
Replace plastic wire tie wraps with metal supports (spaced no more than 24 inches apart).
Due 15 February 2008
Resolved 25 February 2008
Stability › Watertight Integrity › General
Issued 15 March 2007 Resolved
Remove and weld up open pipe in water tight aft bulkhead center line in #3 void.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 April 2007
Resolved 9 April 2007
Resolution: COMPLETED
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 March 2007 Resolved
Provide updated Coastal Pilot, Light list, and Nav Rules.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2007
Resolved 9 April 2007
Resolution: PUBS ON BOARD
Engineering › Bilge Water Management System › Eductor
Issued 13 March 2007 Resolved
Renew basket and fittings on bilge suction in the #2 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2007
Resolved 9 April 2007
Resolution: CORRECTED
Lifesaving › Lifefloat › Painter
Issued 12 December 2005 Resolved
Provide and install painter, float-free link, and light for life float.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 21 December 2005
Resolution: Installed painter, float free link, and float light
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 12 December 2005 Resolved
Replace wasted screen guards on generator housing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 21 December 2005
Resolution: Installed new screen on generator.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 December 2005 Resolved
Remove non-hazardous, 220 volt, welding receptacle in generator space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 21 December 2005
Resolution: Remove welding receptacle from hazardous area.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 12 December 2005 Resolved
Install remote cut-out valve for LPG to gas stove in galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 21 December 2005
Resolution: Install remote cut-out valve for galley stove LPG.
Deck/Cargo › Cargo Stowage › General
Issued 16 December 2004 Resolved
Propane tank on deck improperly secured.
Condition: Improper Installation
Due 15 January 2005
Resolved 13 January 2005
Resolution: Propane tank secured
Engineering › Pressure Vessel › Support
Issued 16 December 2004 Resolved
Properly secure portable air compressor in engine room.
Condition: Improper Installation
Due 15 January 2005
Resolved 13 January 2005
Resolution: Compressor secured
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 16 December 2004 Resolved
Provide proper flame screens in vents for port and starboard fuel storage tanks and day tank.
Condition: Improper Installation
Due 15 January 2005
Resolved 13 January 2005
Resolution: Flame screen installed
Electrical › Electric Supply System (service) › Cable
Issued 16 December 2004 Resolved
Shore power cable was severed and improperly spliced back together.
Condition: Damaged By Earlier Event
Due 15 January 2005
Resolved 13 January 2005
Resolution: respliced cable
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 December 2004 Resolved
Terminals on 32 volt and 12 volt batteries need to be properly covered.
Condition: Improper Installation
Due 15 January 2005
Resolved 13 January 2005
Resolution: Installed rubber boots
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 16 December 2004 Resolved
Adjust packing gland on port propeller shaft to reduce excessive leackage.
Condition: Improper/Lack of Maintenance
Due 15 January 2005
Resolved 13 January 2005
Resolution: Inspected sat
Engineering › Bilge Water Management System › Not Operational
Issued 16 December 2004 Resolved
Make all bilge alarms operable and proberly label bilge alarm indicators on bridge with location of alarm.
Condition: Improper Installation
Due 15 January 2005
Resolved 13 January 2005
Resolution: tested sat
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 December 2004 Resolved
Install cover on electrical distribution circut breaker panel in engine room.
Condition: Improper Installation
Due 15 January 2005
Resolved 13 January 2005
Resolution: Installed cover
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 16 December 2004 Resolved
Crew must provide valid first aid card. COI requires only one crew member. Crew member operating the vessel must posess a valid first aid card. If there is more than one crewmember on the vessel 50% of the crew must have a valid first aid card.
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 13 January 2005
Resolution: Valid 1st aid card on board for Capt.
Communications › Audible Communications › SPD (Other)
Issued 16 December 2004 Resolved
Repair public address system or porvide portable bull horn.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 13 January 2005
Resolution: Bull Horn on Board
Engineering › Bilge Water Management System › Pump
Issued 16 December 2004 Resolved
Provide portable hand bilge pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 13 January 2005
Resolution: Portable bilge pump on board
Engineering › Fuel Oil Service System › Filter
Issued 16 December 2004 Resolved
Flame shields must be fitted on bottom of fuel strianer/filters on main engines.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 13 January 2005
Resolution: Flame impengement bowls installed
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 16 December 2004 Resolved
Stowage, embarkation arrangement and survival craft equipment for the boyant apparatus must meet the requirements of 46 CFR Part 180 subchapter D.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 January 2005
Resolved 13 January 2005
Resolution: Boyant apparatus properly mounted
Lifesaving
Issued 28 April 2000 Resolved
NEED 4FT PADDLES AND A FLOAT LIGHT FOR LIFE FLOAT.
Condition: Unknown
Due 9 May 2000
Resolved 12 May 2000
Navigation
Issued 28 April 2000 Resolved
NAVIGATION LIGHTS NEED BLACK MATTING BACKGROUND.
Condition: Unknown
Due 9 May 2000
Resolved 12 May 2000
Electrical
Issued 28 April 2000 Resolved
ELECTRICAL BOXES IN PILOT HOUSE MISSING PLUGS.
Condition: Unknown
Due 9 May 2000
Resolved 12 May 2000
Electrical
Issued 28 April 2000 Resolved
WIRE NUTS NEED TO BE PROPERLY SECURED WITH ELECTRICAL TAPE.
Condition: Unknown
Due 9 May 2000
Resolved 12 May 2000
Electrical
Issued 28 April 2000 Resolved
ALL DEAD END WIRE RUNS NEED TO BE REMOVED OR CAP OFF. SUPPLY ROOM, PILOT HOUSE, ENGINE ROOM.
Condition: Unknown
Due 9 May 2000
Resolved 12 May 2000
Fire Fighting
Issued 28 April 2000 Resolved
PROVE PROPER OPERATION OF BILGE AND FIRE PUMPS. AND ALL FIRE HOSES.
Condition: Unknown
Due 9 May 2000
Resolved 12 May 2000
Engineering
Issued 28 April 2000 Resolved
PROVE PROPER OPERATION OF THE MAIN ENGINES FROM THE PILOT HOUSE.
Condition: Unknown
Due 9 May 2000
Resolved 12 May 2000
Documentation
Issued 4 May 1999 Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Lifesaving
Issued 4 May 1999 Resolved
Provide lifejacket donning placards.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Navigation
Issued 4 May 1999 Resolved
Provide updated charts.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Lifesaving
Issued 4 May 1999 Resolved
Replace port ring life buoy.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Navigation
Issued 4 May 1999 Resolved
Provide updated compass deviation card.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Navigation
Issued 4 May 1999 Resolved
Provide alternate VHF FM radio to meet the Bridge to Bridge Act. 47 CFR 80.1001
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Fire Fighting
Issued 4 May 1999 Resolved
Replace or recharge galley fire extinguisher.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Engineering
Issued 4 May 1999 Resolved
Provide means for shutting down propulsion machinery in pilot house.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Engineering
Issued 4 May 1999 Resolved
Install flame impingement bowl on port MDE fuel filter.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Construction/Loadline
Issued 4 May 1999 Resolved
Provide bilge alarms in the engine room and generator compartment.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Electrical
Issued 4 May 1999 Resolved
Provide electrical one line diagram for newly installed bow flood lights.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Deck/Cargo
Issued 4 May 1999 Resolved
Replace all cracked & worn hydraulic hoses.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Construction/Loadline
Issued 23 February 1999 Resolved
SEAL HOLES BETWEEN WEATHER DECK AND ENGINE ROOM NEAR CIRCUIT BREAKER.
Condition: Unknown
Due 23 February 1999
Resolved 23 February 1999
Construction/Loadline
Issued 23 February 1999 Resolved
CROP AND RENEW INDICATED AREAS IN THE #5 TRANSVERSE FRAME PORT SIDE AND BULKHEAD AREA OF COLLISION BULKHEAD PORT SIDE.
Condition: Unknown
Due 23 February 1999
Resolved 23 February 1999
Lifesaving
Issued 2 May 1997 Resolved
Provide 2 type I PFD's on board NLT 09 May 97. Crew is limited to four until requirement is met.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Navigation
Issued 4 April 1996 Resolved
Replace worn cutlass bearings on port and stbd shafts.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Construction/Loadline
Issued 4 April 1996 Resolved
Hole in upper port side of bulkhead between engineroom and generator space.Repair and make watertight.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Construction/Loadline
Issued 4 April 1996 Resolved
Repair wasted deck and hydraulic fittings through the main deck port side midships.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Electrical
Issued 4 April 1996 Resolved
Provide suitable battery box for battery in generator room and complete newbattery box in engineroom.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Construction/Loadline
Issued 4 April 1996 Resolved
Replace all non-metallic bilge piping with acceptable metallic piping.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Electrical
Issued 4 April 1996 Resolved
Provide 5/8" metal bands every 24" for all wire runs. Currently using plastic ties.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Lifesaving
Issued 3 May 1995 Resolved
PROVIDE TWO PFD'S TOTAL PERSONS ON BOARD REDUCED TO 4 UNTIL PROVIDED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Lifesaving
Issued 3 May 1995 Resolved
PROVIDE SIX (6) HAND HELD RED FLARES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Lifesaving
Issued 3 May 1995 Resolved
PROVIDE ONE APPROVED RING BOUY LIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1995
Resolved 4 May 1995
Lifesaving
Issued 3 May 1995 Resolved
PROVIDE ONE RING BOUY_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1995
Resolved 4 May 1995
Lifesaving
Issued 3 May 1994 Resolved
LIFE FLOAT NEEDS TO BE FLOAT FREE
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Lifesaving
Issued 3 May 1994 Resolved
REMOVE PAINT FROM OFFICE AFT OF PILOTHOUSE.
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Documentation
Issued 3 May 1994 Resolved
PROVIDE PROOF OF RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Construction/Loadline
Issued 3 May 1994 Resolved
PAINT NAME ON BOW AND "PINTAIL" ON STERN.
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Lifesaving
Issued 3 May 1994 Resolved
PROVIDE "NO OPEN LIGHTS/SMOKING/VISITORS" SIGN.
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Electrical
Issued 3 May 1994 Resolved
CHANGEOUT 4 30 AMP BREAKERS TO 20 AMP ON THE 32 VOLT PANEL
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Engineering
Issued 3 May 1994 Resolved
PROVIDE FLAME IMPINGEMENT BOWLS ON MDE FUEL FILTER.
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Lifesaving
Issued 3 May 1994 Resolved
Renew hydrostatic release for EPIRB or remove EPIRB
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Unknown
Issued 3 May 1994 Resolved
PROVIDE SIDE PROFILE PHOTO OF VESSEL FOR VESSEL FILE.
Condition: Unknown
Due 15 August 1994
Resolved 22 August 1994
Electrical
Issued 3 May 1994 Resolved
REMOVE DEAD-END WIRING.
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Construction/Loadline
Issued 3 May 1994 Resolved
INSTALL SEA SUCTION VALVE REACH ROD.
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Engineering
Issued 3 May 1994 Resolved
INSTALL VALVES ON FUEL GUAGING DEVICE.
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994
Engineering
Issued 3 May 1994 Resolved
LABEL FUEL VALVE SHUTOFFS
Condition: Unknown
Due 19 August 1994
Resolved 22 August 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.