MAURY USCG vessel records Sign in
← All vessels

DIVINE FAITH EXPRESS

DIVINE FAITH EXPRESS is a 1962 freight ship. The Coast Guard has recorded 36 inspections since 2003, most recently in February 2024, along with 58 deficiencies and 20 operational controls.

Records from 2003 to 2024. Most recent: inspection, 5 February 2024.

Built
1962
Last inspected
5 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5065366 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZKU2104
652074
Flag
TANZANIA
—
Maury page id
psix-652074

Inspections, by type

…with no type recorded20
Years with a record 6 calendar years (2003–2024)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it274 - Convention (Subpart B), Gross Ton
264 - Regulatory (Subpart C or D), Gross Ton
149 - Convention (Subpart B), Net Ton
149 - Regulatory (Subpart C or D), Net Ton
450 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 36

5 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7860932
5 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7860952
7 May 2007 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2924446
5 May 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2922699
3 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2921139
27 February 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2878699
19 January 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2868695
17 October 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2802310
2 October 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2791631
6 February 2006 Random ISPS/MTSA/PSC · STCW 95 Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2579985
4 February 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2579306
29 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2575580
7 December 2005 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2547407
26 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2540927
7 November 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2529981
11 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2257726
5 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2253626
22 November 2004 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2245724
29 October 2004 ISPS I Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2231004
29 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2232550
28 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2232888
22 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2225911
29 June 2004 PI Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2098878
25 June 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2110736
24 June 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2108879
18 June 2004 Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2103001
14 June 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2098469
21 May 2004 Periodic Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2073766
9 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2040810
2 April 2004 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2035999
27 March 2004 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2032755
25 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2031085
29 October 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1938531
26 October 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1936236
23 September 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1910755
16 September 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1905961

Deficiency record · 58

Lifesaving › Inflatable Liferafts › Servicing
Issued 19 January 2007 Resolved
Liferaft not onboard vessel due to servicing.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2007
Resolved 27 February 2007
Resolution: Liferafts were properly serviced and on board the vessel.
Fire Fighting › Fire Main › Condition
Issued 19 January 2007 Resolved
Fire Station #1 fire box severely wasted. Box cannot open manually.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2007
Resolved 27 February 2007
Resolution: Fire Station Box was replaced
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 2 October 2006 Resolved
Able Seaman, oiler and cook did not have valid medical certificates.
Action required: 705 - Other - as specified
Resolved 17 October 2006
Resolution: Vsl faxed valid medical certificates for the AB, Oiler and Cook.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 February 2006 Resolved
Vsl is not manned in accordence with Minimum safe manning document. Vsl does not have a chief officer.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Lifesaving › Inflatable Liferafts › Servicing
Issued 7 December 2005 Resolved
Ensure liferafts are serviced by 01/01/2006
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2006
Resolved 21 December 2005
Lifesaving › Rescue Boat › Transom
Issued 7 December 2005 Resolved
Make recue boat operational and repair or replace transom prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 December 2005 Resolved
service all portable fire extinguishers prior to loading cargo
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2005
Fire Fighting › Fire Pumps › Power Source
Issued 7 December 2005 Resolved
make opertaonal main fire pump prior to cargo operations
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2005
Engineering › Compressed Air System (start air) › Compressor
Issued 7 December 2005 Resolved
properly repair air start system for main engine
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2005
Engineering › Generator (propulsion-electric) › Battery
Issued 7 December 2005 Resolved
cover battery for emergency generator and replace protective panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2005
Engineering › Generator (propulsion-electric) › Wiring
Issued 7 December 2005 Resolved
repair and make operational ship service generator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2005
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 7 December 2005 Resolved
remove all flammable liquids and place in paint locker from forpeake space
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2005
Engineering › Fuel Oil Service System › Gauge
Issued 7 December 2005 Resolved
replace plactic sight guage with glass sight guage on fuel tank
Action required: 705 - Other - as specified
Due 21 January 2006
Resolved 5 October 2006
Navigation › Piloting/Steering › Notices to Navigation
Issued 7 December 2005 Resolved
correct all navigational charts with current notice to mariners corrections.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2005
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 7 December 2005 Resolved
provide copy of code of safety for caribbean cargo ship safety code (ccssc)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2005
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 7 December 2005 Resolved
provide flag state endorsements for chief engineer and chief mate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2005
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 7 December 2005 Resolved
provide medical certificate for a/b.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 29 October 2004 Resolved
Provide portable extinguisher service reports for all required fire extinguishers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 October 2004 Resolved
Repair emergency power for SSB radio, navigation lights and all required equipment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2004
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 29 October 2004 Resolved
Properly adjust main shaft seal to reduce amount of water.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2004
Communications › Alarms/Indicators › General Alarm
Issued 29 October 2004 Resolved
Repair general alarm to sound throughout the ship.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2004
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 29 October 2004 Resolved
Install guard on main engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2004
Engineering › Sea-water System (primary cooling) › Valve
Issued 29 June 2004 Resolved
Two leaking valves connected by starboard seachest. Make proper and proper repairs to the satisfaction of class with a survey report submitted to this Office.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 October 2004
Fire Fighting › International Shore Connection › Washers
Issued 29 June 2004 Resolved
Missing four washers and the International Shore Connection is not marked in the current Fire Comtrol Plan. Provide 4 additional wahsers for the connection and have class make proper adjustment to the plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 October 2004
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 June 2004 Resolved
E-generator does not have fuel. Provide adequate supply of fuel to the e-generator fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 October 2004
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 29 June 2004 Resolved
Able Seaman possessed an expired medical certificate. Conduct a physical fitness exam by an licensed Physician and provide copy of updated medical certificate signed by attending physician to this Office.
Action required: 705 - Other - as specified
Resolved 29 October 2004
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 29 June 2004 Resolved
All smoke detectors inside the vessel are inoperable. Make proper maintenance and provided class survey report to this Office.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 November 2004
Fire Fighting › Fire Hydrants › Material
Issued 29 June 2004 Resolved
Missing sapenner wrenches in the majority of the fire stations. Provide one wrench on each station to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 October 2004
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 June 2004 Resolved
Provide adequate amount of potable dirinking water for the crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 October 2004
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 29 June 2004 Resolved
Provide adequate amount of provision for the crew on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 October 2004
Engineering › Fuel Oil Service System › Tank
Issued 29 June 2004 Resolved
Provide sufficient fuel on board vessel for voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 October 2004
Communications › Radio Communications
Issued 2 April 2004 Resolved
HF Radio installation missing. Install radio IAW CCSSC Reocrd of Equipment. LEGACY COMPONENT DESC: VFH Radiotelephone
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2004
Resolved 9 April 2004
Resolution: Observed and tested with satisfactory results installed HF Radio.
Engineering › Bilge Water Management System
Issued 2 April 2004 Resolved
Cargo bilge line starboard side flange leaking fuel. Remove fuel from cargo/engine room bilges. Provide receipt. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2004
Resolved 13 April 2004
Fire Fighting › Structural - Horizontal Zones › General
Issued 2 April 2004 Resolved
Two large holes in overhead of engine room port/starboard sides. Make permanent/proper repairs (crop & renew steel) LEGACY COMPONENT DESC: Engine Room Overhead
Action required: 15 - Rectify deficiencies by next port
Due 2 April 2004
Resolved 29 June 2004
Resolution: Recieved satisfactory survey report plus witnessed permanent repairs.
Fire Fighting › Structural - Horizontal Zones › General
Issued 2 April 2004 Resolved
Overhead vistibule aft of galley leading to the engine room is severely wasted and patched with concrete. Make permanent/proper repairs (crop & renew steel) to overhead. LEGACY COMPONENT DESC: Engine Room Vestibule Overhead
Action required: 15 - Rectify deficiencies by next port
Due 2 April 2004
Resolved 29 June 2004
Resolution: Recieved satisfactory survey report plus witnessed permanent repairs.
Stability › Watertight Integrity › General
Issued 2 April 2004 Resolved
Ballast water piping prot side has several temporary repairs. Make permantent/proper repairs (crop/renew steel) LEGACY COMPONENT DESC: Ballast Piping
Action required: 15 - Rectify deficiencies by next port
Due 2 April 2004
Resolved 29 June 2004
Resolution: Recieved satisfactory survey report plus witnessed permanent repairs.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 April 2004 Resolved
Piping for engine cooling starboard side is holed and constructed of unapproved material (thing walled copper piping). Make permanent/proper repairs (crop/renrew steel).
Action required: 15 - Rectify deficiencies by next port
Due 2 April 2004
Resolved 29 June 2004
Resolution: Recieved satisfactory survey report plus witnessed permanent repairs.
Construction/Loadline › Structures › Superstructure
Issued 2 April 2004 Resolved
Superstructure is wasted and holed on recue boat deck near base (right where bulkehead meets deck). Make permanent/proper repairs (crop/renew) wasted and holed areas.
Action required: 15 - Rectify deficiencies by next port
Due 2 April 2004
Resolved 29 June 2004
Resolution: Recieved satisfactory survey report plus witnessed permanent repairs.
Fire Fighting › Structural - Horizontal Zones › General
Issued 2 April 2004 Resolved
Renewed section of overhead is improper materials (diamond plate) Remove diamond plate and repair with proper material. LEGACY COMPONENT DESC: Diamond Plate
Action required: 15 - Rectify deficiencies by next port
Due 2 April 2004
Resolved 29 June 2004
Resolution: Recieved satisfactory survey report plus witnessed permanent repairs.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 April 2004 Resolved
Fire control plan does not accuraetely represent th evessel's fire fighting and life saving arrangement. Update plan to accurately depict vessel's arrangement.
Action required: 15 - Rectify deficiencies by next port
Due 2 April 2004
Resolved 29 June 2004
Resolution: Observed updated plan with proper arrangement of lifesaving equipment.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 2 April 2004 Resolved
Have flag state appointed representative provide gauging report of vessel's hull as well as a full survey of vessel. Provide report to USCG MSO Miami.
Action required: 15 - Rectify deficiencies by next port
Due 2 April 2004
Resolved 29 June 2004
Resolution: Recieved satisfactory gauging report for the vessel''s hull.
Navigation
Issued 26 October 2003 Resolved
Vessel shall be provided with an effective inclinometer. LEGACY COMPONENT DESC: Inop inclinometer
Due 29 October 2003
Resolved 29 October 2003
Engineering
Issued 26 October 2003 Resolved
Flag state shall provide report indicating satisfactory operation of air compressor and ballst pumps. LEGACY COMPONENT DESC: Compressor
Due 29 October 2003
Resolved 29 October 2003
Operations/Management
Issued 26 October 2003 Resolved
Vessel shall remove cargo blocking fire stations. LEGACY COMPONENT DESC: Cargo arrangement
Due 29 October 2003
Resolved 29 October 2003
Lifesaving › Rescue Boat
Issued 26 October 2003 Resolved
Adjust rail impeding operation of rescue boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2003
Operations/Management
Issued 26 October 2003 Resolved
Remove cargo impeding access to E-generator and International shore connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2003
Navigation
Issued 26 October 2003 Resolved
Vessel shall have stability calculations before its departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2003
Operations/Management
Issued 26 October 2003 Resolved
Paint and batteries stored together.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2003
Lifesaving
Issued 26 October 2003 Resolved
Hydrostatic release installed improperly LEGACY COMPONENT DESC: Hydrostatic release
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2003
Engineering
Issued 26 October 2003 Resolved
Connection for air tanks from mannual compresson missing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2003
Stability › Watertight Integrity
Issued 23 September 2003 Resolved
Engine room overhead bulkhead shows signs of wastage (holes).
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2003
Resolved 26 October 2003
Lifesaving › Lifebuoys
Issued 23 September 2003 Resolved
Lifebuoys are missing self-igniting lights. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2003
Operations/Management › Drills/Instruction
Issued 23 September 2003 Resolved
Did not witness a satisfactory fire drill. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2003
Operations/Management › Drills/Instruction
Issued 23 September 2003 Resolved
Did not witness a satisfactory abandon ship drill. LEGACY COMPONENT DESC: Abandon Ship
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2003
Navigation › Collision/Grounding Avoidance
Issued 23 September 2003 Resolved
Primary radar not functioning. MSO Miami issues a Letter of Deviation. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2003
Resolution: Verified satisfactory operation of radar.
Electrical › Electrical Distribution System (service)
Issued 23 September 2003 Resolved
Wiring behind engine room main control panel are dead-ended/not properly terminated. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 October 2003
Resolved 26 October 2003
Resolution: Wiring no longer in use and will be removed.
Documentation › Certificates/Documents
Issued 16 September 2003 Resolved
Vessel's ITC is invalid. ITC tonnage is lower than national tonnage. LEGACY COMPONENT DESC: International Tonnage Certificate
Action required: 15 - Rectify deficiencies by next port
Resolved 23 September 2003
Resolution: 23Sep03 - Inspected vessel''s documents to determeined that ITC is valid until 08Dec03.
Construction/Loadline
Issued 16 September 2003 Resolved
Vessel does not meet the dry dock requirements delineated in CCSSC. LEGACY COMPONENT DESC: Dry Dock
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.