Records from 2016 to 2026. Most recent: inspection, 29 January 2026.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 6.5 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROZEMA BOAT WORKS INC · MOUNT VERNON, WA, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
29 January 2026
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8288182
8 January 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8280031
14 January 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8063021
1 February 2024
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7852485
19 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7849686
1 February 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7630045
27 January 2022
Hull Examination · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7386286
25 January 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7130090
21 January 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6892823
12 February 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6624475
18 January 2019
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6612415
30 November 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6589921
15 January 2018
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6338117
19 December 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6326567
9 February 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6087392
23 January 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6075205
25 January 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5803003
15 January 2016
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5798426
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 January 2026
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The serpentine drive belts on both the port side and starboard side engines are currently exposed . To prevent accidental access and potential injury, these belts must be properly covered.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 2 February 2026
Resolution: Recieved Photo evidence.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 January 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI except during and emergency. Missing/damaged structural fire protection on forward and starboard bulkheads of engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2025
Resolution: Received photos of replacement for affected areas.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 14 January 2025
Resolved
COI specifies minimum complement of officers and crew necessary for the safe operation of the vessel. Although an MMC serves as a certificate of identification, a TWIC must be retained by the mariner by whom it was issued. The Coast Guard issues a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Licensed mate missing TWIC and medical credential; missing documentation for one deckhand.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2025
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 February 2024
Resolved
Electrical equipment must provide services and electrical hazards minimalized. Open wires on engine and bulkhead must be removed or purposely in service.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 29 February 2024
Resolution: Wires verified as serving no purpose and removed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 February 2024
Resolved
Emergency egress training for each crewmember must be monthly. Egress training was not completed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 February 2024
Resolution: Ran drill including egress as part of inspection to ensure crew was trained on requirement and how to meet it.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 February 2024
Resolved
EPIRB test required shall be logged. EPIRB test was not logged.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 February 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 February 2023
Resolved
Watertight bulkhead penetration must be watertight; Watertight penetrations associated with fire boy system are not watertight; To use rocks blocks, fire-stop, or similar installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 February 2023
Resolved
Fire hose must conform to UL19 or equivalent standard; Fire hose burst while testing fire pump. To replace.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 February 2022
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements must be designed, installed, and maintained with approved standard. The pump outlet to the fire pump must be fitted with a working pressure gauge. Pressure gauge at the pump outlet and pressure gauge inoperable. Replace gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 4 February 2022
Resolution: Vessel rep provided photographic evidence of fire pump gauge being replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 February 2022
Resolved
Each ring buoy with a floating waterlight must be maintained in accordance with subchapter Q of this chapter. Waterlight battery expired, replace battery in waterlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 4 February 2022
Resolution: Vessel rep provided photographic evidence of light list battery being replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 January 2022
Resolved
A hatch exposed to the weather shall be watertight. WTH had a deteriorated gasket; Attended vessel on 01FEB22 for annual inspection, watertight gasket not yet repaired. Updated code to 17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2022
Resolved 1 February 2022
Resolution: Vessel rep provided photographic evidence of gasket being replaced.