MAURY USCG vessel records Sign in
← All vessels

DAUNTLESS

DAUNTLESS is a 2003 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 2003, most recently in August 2023, along with 29 deficiencies and 10 casualty investigations between 2004 and 2023.

Records from 2003 to 2023. Most recent: inspection, 9 August 2023.

Built
2003
Last inspected
9 August 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB5381
654512
Flag
UNITED STATES
366909020
Maury page id
psix-654512

Inspections, by type

…with no type recorded11
Years with a record 17 calendar years (2003–2023)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB5381MMSI 366909020 · active · compulsorily equipped · granted 8 October 2022, expires 13 November 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 40

9 August 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7769985
9 August 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7776138
26 October 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7583920
6 June 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7542026
9 December 2021 Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7363632
22 November 2021 DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7362186
28 October 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7341455
14 September 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7321848
2 November 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087417
16 January 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6891685
18 December 2019 Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6876484
6 December 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6885384
7 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6830928
15 February 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6642121
5 November 2018 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6575150
5 February 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6350024
4 December 2017 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6316056
23 January 2017 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6087826
14 October 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6034326
4 December 2015 Drydock Exam · In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5774742
23 November 2015 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5788222
11 November 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5764822
22 February 2012 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4248948
6 December 2010 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3979057
5 December 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3912254
11 December 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3648639
24 April 2009 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3459870
19 January 2009 Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 3396708
26 November 2008 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3370094
26 June 2008 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3248792
21 February 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3151191
17 April 2007 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2909578
25 May 2006 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2658944
7 February 2006 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2581047
9 August 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2182770
6 March 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2288288
10 February 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2003975
6 January 2004 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1977060
18 December 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1966682
19 November 2003 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1941225

Deficiency record · 29

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 26 October 2022 Resolved
FCC requires mariners that operate a vessel with more than 6 passengers to have a valid FFC Marine Radio Operator Permit(MROP). Vessel master did not have FCC MROP. Master shall provide MROP. 47 CFR 13.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2022
Resolved 7 December 2022
Resolution: MROP provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 October 2022 Resolved
Life float painter must be at least 100 ft in length, be of a dark color if synthetic, or of a type certified to be resistant to deterioration from UV light, and be stowed in a way that it runs out freely when the life float floats away. Painter deteriorated. Provide new painter. 46 CFR 180.175(f)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2022
Resolved 14 November 2022
Resolution: New painter provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2021 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel missing windlass device. Submit repair proposal to install missing mechanism in kind. 46 CFR 176.800(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2022
Resolved 6 January 2022
Resolution: Windlass removed. Wiring end put into J-box.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 November 2021 Resolved
The selection of crewmembers for random drug testing shall be made by a scientifically valid method, such as a random number generator that is matched with crewmembers' Social Security numbers, payroll identification numbers, or other comparable identifying numbers. Under the testing frequency and selection process used, each covered crewmember shall have an equal chance of being tested each time selections are made and an employee's chance of selection shall continue to exist throughout his or her employment. Current selection process is not a scientifically valid method. Ensure random selection process complies with the above requirements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2021
Resolved 22 November 2021
Resolution: DER identified and implemented acceptable scientific random selection process.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 October 2021 Resolved
Each portable fire extinguisher required must be acceptable to the Officer In Charge, Marine Inspection. 03 portable fire extinguishers showing corrosion on cylinder. Replace fire extinguishers. 46 CFR 181.500
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2021
Resolution: Portables replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 October 2021 Resolved
Each item of survival craft equipment must be of good quality. 01 life float condemned due to severe cracks. 01 life float has minor damage and needs repaired Replace 01 life float and repair 01 life float in accordance with manufacture specifications or replace in kind. 46 CFR 180.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 17 November 2021
Resolution: New life float provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 October 2021 Resolved
A vessel shall have visual and audible alarm provided at the operating station to indicate a high water level in each machinery space. Bilge high level audible alarm in laz not operating as designed. Make audible high level alarm operational as designed. 46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 October 2021
Resolution: Alarm opertional.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel. 46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 22 November 2021
Resolution: EAP Training provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2020 Resolved
The discharge ends of fuel tank vent pipes must terminate on the hull exterior as high above the waterline as practicable and remote from any hull openings, or they must terminate in U-bends as high above the weather deck as practicable and as far as practicable from openings into any enclosed spaces. Vent pipes terminating on the hull exterior must be installed or equipped to prevent the accidental contamination of the fuel by water under normal operating conditions. Diesel fuel vents onboard vessel vent into vessel. At next drydock install proper venting for fuel tanks in accordance with approved vessel drawings dated 12 July 2000.
Action required: 705 - Other - as specified
Resolved 23 August 2021
Resolution: Fuel tank vent to exterior installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 October 2019 Resolved
Fireboy audible alarm at the operating station was inoperable. Prove correct operation in accordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 7 October 2019
Resolution: Received video of audible alarm at operating station.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 January 2017 Resolved
First aid kit was not complete and dirty.
Due 23 February 2017
Resolved 14 February 2017
Resolution: First aid kit was fully stocked and cleaned.
Lifesaving › Lifefloat › Painter
Issued 23 November 2015 Resolved
Painter was not attached to the correct spot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2015
Resolution: Painter was attached to the correct place.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 22 February 2012 Resolved
Provide lights for PFD's prior to conducting coastwise voyages.
Action required: 705 - Other - as specified
Resolved 22 February 2012
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 February 2012 Resolved
Provide alcohol testing device aboard.
Action required: 705 - Other - as specified
Resolved 22 February 2012
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 November 2008 Resolved
Renew seven adult PFD's
Due 26 November 2008
Resolved 26 November 2008
Resolution: Corrected during course of inspection.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 26 November 2008 Resolved
Provide compass deviation table.
Action required: 705 - Other - as specified
Due 28 December 2008
Resolved 8 January 2009
Operations/Management › Drills/Instruction
Issued 18 December 2003 Resolved
Prove efficiency in fire and MOB drills IAW 46 CFR 185.520, 524. LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 December 2003 Resolved
Affix life jacket lights to each life jacket carried on board IAW 46 CFR 180.75 LEGACY COMPONENT DESC: Lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2003
Lifesaving › Buoyant Apparatus
Issued 18 December 2003 Resolved
Mark the name of the vessel on each of the life float paddles IAW 46 CFR 185.604
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 18 December 2003 Resolved
Provide certification of inspection for the fixed fire fighting system IAW 46 CFR 176.810 (b)(2) LEGACY COMPONENT DESC: Tanks
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2003
Documentation › Certificates/Documents
Issued 18 December 2003 Resolved
Provide an FCC safety certificate IAW 46 CFR 184.502 LEGACY COMPONENT DESC: FCC SSL
Due 5 January 2004
Resolved 22 December 2003
Documentation › Markings/Placards
Issued 18 December 2003 Resolved
The following items were not posted in the appropriate position: 1) stability letter 2) emergency broadcast placard 3) MARPOL placard 4) oil pollution placard 5) life jacket donning placard 6) life jacket location placards 7) max passenger for upper deck markings
Due 5 January 2004
Resolved 22 December 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 18 December 2003 Resolved
Mount the bridge portable fire extinguisher LEGACY COMPONENT DESC: Mounting Bracket
Due 5 January 2004
Resolved 22 December 2003
Fire Fighting › Miscellaneous Items
Issued 18 December 2003 Resolved
Affix lanyard and mark vessels name on the three fire buckets.
Due 5 January 2004
Resolved 22 December 2003
Engineering › Bilge Water Management System
Issued 18 December 2003 Resolved
Provide a hand portable bilge pump LEGACY COMPONENT DESC: Pump
Due 5 January 2004
Resolved 22 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 18 December 2003 Resolved
Mount a suitable guard for the starboard engine belt drive system LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 5 January 2004
Resolved 22 December 2003
Operations/Management › Drills/Instruction
Issued 19 November 2003 Resolved
Conduct fire and man overboard drills to satisfaction of local OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2004
Resolved 22 December 2003
Operations/Management › Drug and Alcohol Testing
Issued 19 November 2003 Resolved
Demonstrate compliance with 46 CFR 16 drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2004
Resolved 22 December 2003
Operations/Management › Passenger Operations
Issued 19 November 2003 Resolved
Conduct new to zone inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2004
Resolved 22 December 2003

Casualty record · 10

6 March 2004Routine · role: Involved in a Marine Casualty · activity 2288288
5 December 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3912254
24 February 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4539686
11 November 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5764822
14 October 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6034326
15 February 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6642121
6 December 2019Routine · role: Involved in a Marine Casualty · activity 6885384
14 September 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7321848
6 June 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7542026
9 August 2023Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7776138
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record