Records from 2003 to 2025. Most recent: inspection, 25 December 2025.
Inspection history · 28
25 December 2025
COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8284265
13 September 2021
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7311063
2 October 2020
PSC B · COC-CHEM Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7069912
30 July 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7020111
20 March 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6929518
2 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6826680
14 September 2019
ISPS III Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6808485
6 August 2019
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6774830
23 January 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6614214
16 October 2018
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6560784
22 October 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6292715
9 June 2017
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6170763
5 January 2010
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3658932
13 May 2009
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3474056
13 February 2009
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3417523
21 July 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3275211
16 January 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3135154
1 November 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3091656
19 October 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3082955
13 October 2007
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3078958
8 May 2007
ISPS II Exam · Ballast Water Examination · NPV Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2924175
14 October 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2800156
10 October 2006
Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2797839
27 September 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2792228
20 June 2006
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2685626
4 October 2005
ISPS II Exam · COC-CHEM Annual
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2508139
27 October 2004
ISPS II Exam · COC-CHEM Annual
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2229356
3 October 2003
Certificate of Compliance
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1924623
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 September 2019
Resolved
10119: Rudder, propeller, thrust, pitch and operational mode indicators or other means to determine and display rudder angle, all to be readable from the conning position. PSCO observed during steering test that all rudder angle indicators on bridge did not match each other or indicator on steering gear system. Bridge indicators varied from 1deg to 6deg off from steering system and each other. SOLAS 74a (09) V/19.2.5.4 16a.c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2019
Resolved 2 October 2019
Resolution: See narrative for details. Class report uploaded to documents.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 1 November 2007
Resolved
The primary pitch control unit failed; resulting in not pitch control signal from bridge to engine room. Vessel must repair prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2007
Resolution: Received satisfactory class report.
Navigation › Piloting/Steering › Gyro Compass
Issued 19 October 2007
Resolved
Received Letter of Deviation request from vessel for malfunctioning gyrocompass.
Action required: 705 - Other - as specified
Due 19 October 2007
Resolved 20 October 2007
Resolution: Received technician report attesting to the proper operation of the vessel''s gyrocompass.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 13 October 2007
Resolved
0220- Masters STCW certificate required by regulation V/I was issued / validated August 2002. STCW Qualification is required at intervals not less than five years, STCW I/II.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2007
Resolution: Received fax from Flag State via agent attesting to proper validation of STCW in accordance with regulations V/1.2 of the I.M.O. STCW 95
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 13 October 2007
Resolved
0220- Third Mates GMDSS and Cargo Certificate, IV/2 and VI, respectively are not reflected on third mate's flag endorsement as required by STCW regulation I/10 regarding flag state endorsement of STCW certificates issued by other administration. STCW I/10.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 October 2007
Resolution: Received fax from Flag State via agent attesting that the 3rd mate has a application for flag endorsement that includes certificate of competence, GMDSS, Oil Tanker Safety and Chemical Tanker Safety.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 13 October 2007
Resolved
0135 Flag State to clarify English translation of special condition number one (i.e. first listed) on VSL Safe Manning Certificate so English text matches the Italian text properly relating content there of. SOLAS 74 V/14.2 (2004 Cons.)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2007
Resolution: Received class report clearing the above deficiency.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 October 2007
Resolved
1860 Vessel has only one of two required O2 (oxygen) meters required by the IBC code. SOLAS 74 VII/10 (2004 cons.) IBC Code 13.2 (1998 ed.)
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 18 October 2007
Resolution: Received class report clearing the above deficiency.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 October 2007
Resolved
1860 One of two explosive gas meters required does not show accurate reading. Meter cannot be calibrated on board and manual instructions indicates sensor is bad. Meter reads 47/48% LEL but should read 50%. SOLAS 74 VII/10 (2004 cons.)
IBC Code 13.2 (98 ed.)
Action required: 15 - Rectify deficiencies by next port
Resolved 13 October 2007
Resolution: Proved proper operation.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 13 October 2007
Resolved
1099 Vessels Vapor Control System High Pressure Alarm was not properly set. PC Valves release at 200 m/bar, alarms are required to be set at 180 m/bar according to vessels approved Vapor Control System Manual and 46 CFR 39.20-13. alarms were set at 196 m/bar. Class to attest to proper setting of vapor control system alarms. 46 CFR 39.20.13, SOLAS IX/3, ISM Code 10.1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 18 October 2007
Resolution: Received class report clearing the above deficiency.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 10 October 2006
Resolved
Unable to provide evidence of current certification of the Vapor Collection System by the class society. Vessel is not authorized to load cargo requiring VCS until certification is provided to the U.S. Coast Guard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2006
Resolution: Received email with the attached RINA vapor collection system certification. The ship is authorized to load cargoes requiring VCS at this time. The next Coast Guard Unit available to do so, is to annotate the ship''s Certificate of Compliance.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 20 June 2006
Resolved
Master reports that one GPS unit is inoperable.
Due 21 June 2006
Resolved 20 June 2006
Resolution: Master indicated that they had 3 other GPS''s on board.