BERNICE LIND

Built
1977
Last inspected
13 January 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 13 January 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2004–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK4147
655015
Flag
UNITED STATES
Maury page id
psix-655015

Documentation record

Registered dimensions (L × B × D)59.5 ft × 22.7 ft × 8.0 ft
Registered tonnagegross 72 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNATIONAL STEEL AND SHIPBUILDING COMPANY · SAN DIEGO, CA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 2 April 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Simplified, Gross Ton
57 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 50 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GATOR Freight Barge · MISLE 185515 · 12 December 2017 · activity 6383692201 Freight Barge · MISLE 45253 · 9 December 2012 · activity 4499709SJ 144 Freight Barge · MISLE 210294 · 23 January 2004 · activity 1995862

Inspection history · 17

13 January 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8058829
15 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7875719
28 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7658677
3 March 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7409517
10 December 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7366193
16 September 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7313937
31 March 2021 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7166597
2 February 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7134816
31 October 2019 Administrative Inspection · Deficiency Check · Initial Certification · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6846528
10 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6558332
16 August 2018 Administrative Inspection · In-Service Inspection · Initial Certification · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6518865
14 May 2018 Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6419624
12 December 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6383692
24 January 2014 Marine Casualty Follow Up
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4788670
9 December 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4499709
3 August 2012 Deficiency Check · Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4403698
23 January 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1995862

Deficiency record · 50

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2025 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Lazarette bilge suction did not have pumping capability due to unknown causes. Portable two inch pump was on-board, but hoses were ashore. Hoses were brought to the vessel and portable pump test was satisfactory. Deficiency cleared on the spot. 46 CFR 143.275
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2025
Resolution: Hoses were brought to the vessel and portable pump test was satisfactory. Deficiency cleared on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2025 Resolved
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. Personnel duties for man-overboard and abandon ship are not posted. Post personnel duties for man-overboard and abandon ship to the satisfaction of the Marine Inspector (MI). 46 CFR 140.405 (c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 25 February 2025
Resolution: Operator emailed new station bill with required duties included.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 13 January 2025 Resolved
Records of drills and instruction must be maintained and must include: (1) The date of the drill and instruction;(2) A description of the drill scenario and instruction topics;(3) The personnel involved. Drill records did not include description or personnel involved. Provide drill records that include description and personnel involved to the satisfaction of the MI. 46 CFR 140.420 (g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 25 February 2025
Resolution: Operator emailed drills over that include details and personnel involved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel under normal and emergency conditions. The starboard engine solenoid valve bracket is broken. Repair solenoid valve bracket to the satisfaction of the MI. 46 CFR 143.205 (a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 15 January 2025
Resolution: Operator provided photographs (attached) with new bracket installation.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 January 2025 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Identified Excessive rust build-up and scaling under the engine room fire pump on the interior hull. Clean area to good metal and apply protective coating to the satisfaction of the MI. 46 CFR 140.605 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 24 January 2025
Resolution: received photo evidence of requirements of 835 being met, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 January 2025 Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel under normal and emergency conditions. Port and starboard exhaust penetrations to the second deck are wasted around the penetration welds. Submit repair proposal to repair the compromised welds to the satisfaction of the MI. 46 CFR 143.205 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 27 January 2025
Resolution: Submitted photos of repairs all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2025 Resolved
The owner or managing operator must implement procedures to identify and mitigate safety hazards. Railing on the second deck, starboard side, is wasted in two locations where the rail meets the deck. Repair railing to the satisfaction of the MI. 46 CFR 140.510 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 27 January 2025
Resolution: Submitted photos of repairs all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 13 January 2025 Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel under normal and emergency conditions. Identified several areas on the engine mounts where the "Chockfast" is cracked and wasted. Replace the wasted areas to the satisfaction of the MI. 46 CFR 143.205 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 5 February 2025
Resolution: Submitted photos of replaced chockfast, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 January 2025 Resolved
The owner or managing operator must implement procedures to identify and mitigate safety hazards. Hot water heater in the engine room is not secured with an adequate securing device. Replace current securing device with one of adequate strength to the satisfaction of the MI. 46 CFR 140.510 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2025
Resolved 15 January 2025
Resolution: Operator provided photos (attached) showing straps of adequate strength.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 April 2024 Resolved
The owner, managing operator, or master of a towing vessel must ensure that the vessel's lifesaving and fire suppression and detection equipment complies with the applicable requirements of parts 141 and 142 of this subchapter and is in good working order. The vessel has a fire pump that is not required due to its excepted status that is leaking from its gasket. 46 CFR 140.650
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2024
Resolved 8 May 2024
Resolution: Witnessed repaired fire pump. No longer leaking.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 March 2023 Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 3ft in length, but not more than 6ft securing the water light around the body of the life buoy. The vessel's life buoys did not have a lanyard securing the water light around the body of the lifebuoy. 46 CFR 141.360(c)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 12 April 2023
Resolution: Received photo of secured water light.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 28 March 2023 Resolved
Personnel dispatched from the vessel or that are working in an area on the exterior of the vessel without rails and guards may wear a work vest approved by the Commandant under 46 CFR 160.053. When worn at night, the work vest must be equipped with a light that is securely attached to the front shoulder area of the lifejacket. Multiple work vests were missing a light attached to the work vest. 46 CFR 140.430 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 12 April 2023
Resolution: Received photo with work vest with light.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 March 2023 Resolved
Each window or portlight, and its means of attachment to the hull or the deckhouse, must be capable of withstanding the maximum expected load from wind. MI observed a cracked aft window on the bridge. 46 CFR 144.920 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2023
Resolved 12 April 2023
Resolution: The cracked aft window has been rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021 Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket, approved under approval series 160.002, 160.005, 160.055, 160.155, or 160.176, for each person on board. Vessel only had four Type I approved lifejackets on board, and was missing four lifejackets. Vessel restricted from carrying more than four persons. 46 CFR 141.340(a)
Action required: 705 - Other - as specified
Resolved 20 April 2021
Resolution: Received electronic documentation depicting the purchased and labeled PFDs with working lights and whistles.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 March 2021 Resolved
Electrical panels or other enclosures containing more than one source of power must be fitted with a sign warning persons of this condition and identifying where to secure all sources. Main electrical panel in the engineroom missing required signage noting where to secure power sources. 46 CFR 143.250(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 20 April 2021
Resolution: Received electronic documentation depicting the required signage.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 November 2019 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: auxiliary generator engine low lubricating oil pressure, auxiliary generator high cooling water temperature and low hydraulic steering fluid levels. No alarms for the generator or hydraulic steering fluid were available at the operating station. Provide a visible and audible means to notify when the essential systems develop a problem.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Conducted operational test at the operating station.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 5 November 2019 Resolved
Each towing vessel must be fitted with a general alarm that is capable of notifying persons in the engine room. The bell failed to work in the engine room. Demonstrate the bell sounding to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 16 January 2020
Resolution: Video provided showing proper alarm volume.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2019 Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Multiple holes located above the bridge console allowing for the intrusion of water. Seal with a material that provides a water barrier and will protect the electrical equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2019 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Burned wires located under the bridge console. Replace damaged wires.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified wires were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2019 Resolved
Electrical conductors passing through watertight bulkheads must be installed so that the bulkhead remains watertight. Electrical equipment running through the bulkhead from the lazarette to the engine room failed to maintain watertight integrity. Seal using approved material.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified watertight boundary was being maintained.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 November 2019 Resolved
Lifebuoys must have the following attachments and fittings: at least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one is carried, at least one lifebuoy must not have a lifeline attached. At least two lifebuoys on a towing vessel greater than 26 ft must be fitting with a floating electric water light approved under 161.010 or 161.110. Each floating electric water light must have a lanyard of at least 3 ft but no more than 6 ft. Lifelines were not secured around the body of the lifebuoys and only one lifebuoy had a waterlight. The lanyard for the waterlight provided was well under 3 ft in length. Provide lifebuoys that are outfitted IAW 46 CFR 141.360.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified proper assembly.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 November 2019 Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Multiple holes located in the bulkhead separating the engine room from accommodation spaces. Properly seal holes to ensure fire boundary.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 16 January 2020
Resolution: Photos provided showing closure of multiple holes in engine room.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 November 2019 Resolved
A towing vessel must carry adequate and up-to-date charts, including electronic charts acceptable to the Coast Guard. The Coast Guard encourages the use of a back-up arrangement when using electronic charts. A secondary system may be an additional ENC display or currently corrected paper charts. Provide a back-up arrangement for your electronic charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified back-up method.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 November 2019 Resolved
Each towing vessel must perform the applicable tests in Table 143.245 (b). The tests required by this section must be recorded in accordance with part 140 of this subchapter. Pre-underway checklists covered most items in Table 143.245 (b), however some items are required to be tested on a less frequent basis. Provide a sufficient method of ensuring all tests are conducted IAW 46 CFR 143.245 to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified check lists to ensure tests are being conducted IAW Table 143.245(b)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 November 2019 Resolved
Records of drills and instruction must be maintained in the Towing Vessel Record or official logbook. The record must include: the date of the drill and instruction, a description of the drill scenario and instruction topics, and the personnel involved. Vessel has been out of service and no record of drill was available for review. Provide a means for recording drills to the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified drill records.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 November 2019 Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. Visual examinations of towing gear were not recorded. Provide a means for recording information required to the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified towing gear record.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 31 October 2019 Resolved
Each VTS User shall carry on board and maintain for ready reference a copy of VTS rules. No VTS rules kept on board. Provide a current copy to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified presence of VTS rules.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 October 2019 Resolved
Any towing vessel with alternating watches or overnight accommodations must identify the duties and duty stations of each person onboard during an emergency including: Responding to fires and flooding, emergencies that necessitate abandoning the vessel, taking action during heavy weather, taking action relative to the tow, taking action in the event of failure of propulsion, steering, or control system, managing individuals onboard who are not crewmembers, managing any other event or condition which poses a threat to life, property or the environment. The emergency duties and sttions must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. Provide updated emergency duties and stations to meet the requirements set forth in 46 CFR 140.405.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 8 January 2020
Resolution: Verified station bill presence and accuracy.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 November 2018 Resolved
Each towing vessel must have either a self priming, power driven, fixed fire pump, a fire main, and hoses and nozzles or a portable pump. Crew could not energize fire pump. Prove proper operation of fire pump prior to conducting operations. 46 CFR 142.325
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 November 2018
Resolved 5 November 2019
Resolution: Vessel has an operational fire pump onboard.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 November 2018 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. Fuel return line for the No. 1 diesel generator was leaking diesel from the valve near the port side forward bulkhead. 46 CFR 143.220(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 20 November 2018
Resolved 8 January 2020
Resolution: Verified no leak present.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2018 Resolved
Welding procedures and welder performance utilized in the fabrication of vessels and their various systems and components subject to Coast Guard inspection shall be qualified as required by the applicable subchapter. Pressure vessel located in the engine room has a pinhole where the mount connects the body of the pressure vessel. Replace or repair pressure vessel using properly qualified welder. 46 CFR 2.75-70(a)
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 20 November 2018
Resolved 5 November 2019
Resolution: Two new pressure vessels were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2018 Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Lazarette and engine room bilge suction do not have installed check valves. Install check/foot valve in lazarette and engine room bilge lines. 46 CFR 143.275
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 20 November 2018
Resolved 5 November 2019
Resolution: Verified check valves are installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 November 2018 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists on an essential system develops problems that require attention. The following alarms must be provided: High bilge levels. Vessel is not outfitted with bilge alarms. Install bilge alarms in each compartment below the main deck. 46 CFR 143.230(a)(5)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 20 November 2018
Resolved 5 November 2019
Resolution: Bilge alarms were installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 November 2018 Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of 142.225 of this subchapter. There are approximately 20 gallons of engine oil stored next to the starboard engine. Relocate oil to a suitable location. 46 CFR 143.220(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 5 November 2019
Resolution: Engine oil was removed from the engine room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2018 Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. Crew could not provide documented maintenance plan for the fuel system. Implement a fuel system maintenance plan in accordance with Subchapter M regulations. 46 CFR 143.255(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 3 December 2019
Resolution: Reviewed fuel system maintenance plan.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 20 November 2018 Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Starboard engine is missing guard around exposed belt. Install proper guard. 46 CFR 140.505(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2018
Resolved 5 November 2019
Resolution: Guard was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 20 November 2018 Resolved
Each vessel fitted with installed bulwarks around the exterior of the main deck must have sufficient freeing ports or scuppers or a combination of freeing ports and scuppers to allow water to run off the deck quickly without adversely affecting the stability of the vessel. Vessel recently installed bulwarks around the vessel and does not have sufficient drainage. Install proper drainage around the maindeck. 46 CFR 144.320(a)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 20 December 2018
Resolved 8 January 2020
Resolution: Verified sufficient drainage.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 October 2018 Resolved
AIS PLACEMENT NOT PROVIDED: incomplete dimension information (AIS Antenna Position “X” equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 January 2020
Resolution: New AIS installed after deficiency issue date.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 August 2018 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing in case of fire each doorway, ventilator, and annular space around funnels and other opening into such spaces. Current arrangement has two air intake vents on stern of main deck and two vents in the engine exhaust stack that do not have methods for closing in the event of fire. 46 CFR 144.605
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: Demonstrated operation of vent closures.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 August 2018 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by using individual battery operated detectors meeting UL 217. Provide documentation for galley and berthing smoke detectors proving they meet UL 217. 46 CFR 142.330(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: Documentation provided.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 August 2018 Resolved
All vessel equipment must be used IAW the manufacturer’s recommended practice and in a manner that minimizes risk of injury or death. This includes machinery equipment. Air filters on both engines excessively covered in air debris. Clean or replace air filters. 46 CFR 140.505(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: Replaced air filters on both engines.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 August 2018 Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Engine room has two small holes in the lower engine room bulkhead. Properly seal holes to ensure fire boundary. 46 CFR 144.405
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: Holes were filled.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 August 2018 Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 1 in. high: WATER TIGHT DOOR-KEEP CLOSED or WATERTIGHT HATCH-KEEP CLOSED. Watertight doors and hatches not properly marked. 46 CFR 144.610(e)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: Proper labels were put on watertight doors and hatches.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 August 2018 Resolved
Each escape hatch and emergency exit used as a means of escape must be marked on both sides in clearly legible letters at least 2 in. high: EMERGENCY EXIT, KEEP CLEAR. Emergency exits not properly marked. 46 CFR 144.610(f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: New doors and labels were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 August 2018 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Properly secure dead end wires on bridge near port radio. 46 CFR 143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: Dead end wires near port radio were secured however, issued new deficiencies for electrical equipment in the vicinity of the bridge console.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 August 2018 Resolved
Towing vessels of 65 feet or less in the length must carry at least the minimum number of hand-portable fire extinguishers set forth in Table 142.230(d)(1). BII extinguisher is not mounted on proper bracket. 46 CFR 142.230(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: BII extinguisher is mounted properly.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 August 2018 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting not installed on internal working and living areas. 46 CFR 143.410
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: Tested emergency lighting.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 August 2018 Resolved
Each mattress must comply with either the consumer product safety commission standard for mattress flammability or IMO Resolution A.688(17). Provide documentation proving mattresses meet this part. 46 CFR 144.430
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 20 November 2018
Resolution: Operators removed mattresses since vessel does not utilize them as berthing.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 August 2018 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. Vessel did not have paperwork onboard to prove compliance with DAPI program. 46 CFR 16.201
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: Provided paperwork to prove compliance with DAPI program.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 August 2018 Resolved
All non-recreational, non-military vessels less than 79 feet in length that are operating in a capacity as a means of transportation are eligible for coverage under this permit. Vessel does not have a sVGP onboard. 2014 sVGP 1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2018
Resolved 5 November 2019
Resolution: Discussed with operator and the sVGP requirement was repealed. It is no longer required.