MAURY USCG vessel records
← All vessels

STOLT KASHI

STOLT KASHI is a 2003 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in July 2025, along with 19 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 2 July 2025.

Built
2003
Last inspected
2 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 July 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9266243
655074
Flag
LIBERIA
Maury page id
psix-655074

Documentation record

Tonnage as PSIX records it15895 - Convention (Subpart B), Gross Ton
25148 - Dead Weight, Metric Ton
32899 - Displacement, Metric Ton
7838 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

2 July 2025 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8172967
22 May 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8140902
20 January 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7851995
17 January 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7618454
2 March 2021 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7146958
15 December 2020 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7111035
21 February 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6909625
22 March 2019 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6647264
25 February 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6631699
1 March 2018 ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6362795
20 February 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6357043
8 February 2018 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6351646
24 February 2017 ISPS II Exam · Deficiency Check · COC-CHEM & TVE Annual · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6093890
14 February 2016 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5809837

Deficiency record · 19

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 May 2025 Resolved
Alternatively, the secondary means may consist of pressure sensors fitted in each tank with a monitoring system in the ships cargo control room. Such monitoring equipment shall also provide an alarm facility which is activated by detection of over pressure or under pressure within a tank. PSCO observed audible and visual alarms for all cargo tanks disabled in CCR. Additionally cargo tank 11CP had no readings for pressure ullage and temperature. After trouble shooting by ships crew no tanks have read outs. 74SOLAS(20)VII/10.1; IBC 8.3.3.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 May 2025 Resolved
Cargo tanks shall be fitted with one of the following gauging devices .3 Closed device - which penetrates the tank but which is part of a closed system and keeps tank content from being released. PSCO observed inconsistent gauging readings across stowage plan, cargo tank monitoring system, and cargo control workstation, variations were between 3 and 9% across all tanks. 74SOLAS(20) VII/10.1; IBC 13.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2025
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 22 May 2025 Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. In addition, it shall be provided with alarm arrangements to indicate when this level cannot be maintained. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 parts per million. In considering the design of such equipment and approvals, the Administration shall have regard to the specification recommended by the Organization. PSCO observed inoperable recording device for the vessel's OWS. The crew did provide a flag dispensation but were not properly following the protocols required by the dispensation. MARPOL ANNEX I/14.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2025
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 22 May 2025 Resolved
Any failure of the oil filtering equipment shall be recorded in the Oil Record Book Part I. PSCO observed no entry in Oil Record Book Part I pertaining to the OWS recorder failure on 16APR2025. Additionally PSCO observed multiple entries attesting to satisfactory test of OWS and monitoring equipment after reporting inop recording device. MARPOL ANNEX I/17.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 May 2025 Resolved
A chemical tanker shall comply with the requirements of the International Bulk Chemical Code...Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. PSCO observed tank radar ground wires missing and also fitted with improper wire size. Ship's crew had replaced original ground wires with improperly sized replacements. 74SOLAS(20) VII/10.1; IBC 10.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2025
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 22 May 2025 Resolved
The system shall be capable of maintaining the atmosphere in any part of any cargo tank with an oxygen content not exceeding 8% by volume and at a positive pressure at all times in port and at sea except when it is necessary for such a tank to be gas-free. PSCO observed that the inert gas generator was not capable of maintaining an oxygen content below 8%. 74SOLAS(2001) II-2/62.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 May 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed leaking pneumatic line on valve controller for IG Blower A. Leak was vaporizing substance around valve controller. 74SOLAS(20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2025
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 22 May 2025 Resolved
In meeting these requirements, Company shall ensure that, .1 Inspections are held at appropriate intervals, .2 any nonconformities are reported, with possible cause if known, .3 Appropriate corrective action is taken. The technical and operational nature of the deficiencies 1-7 provide objective evidence of a failure or lack of effectiveness, of the implementation of the ISM Code. An internal ISM Audit by the company with a report of findings satisfactory to the OCMI must be submitted within 90days. 74SOLAS(20) IX/13.1, ISM Code 10.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 July 2025
Resolution: AUDIT ATTACHED TO MISLE.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 May 2025 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outwards that has a 12.7 mm diameter and is at least 25.4 mm in length. PSCO observed #3 Vapor connection on port side with a less than 1" stud. 46CFR39.2001(j)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 20 January 2024 Resolved
A chemical tanker shall comply with the requirements of the international bulk chemical code and shall, in addition to the requirements of regulation I/8, I/9, and I/10 as applicable, of surveyed and certified as provided for in that condition. 74 SOLAS 20 VII/10.1. Suitably marked decontamination showers and eyewash shall be available on deck in convenient locations. The showers and eye wash shall be operational in all ambient temperatures. PSCO was not able to observe operable showers or eyewash stations due to frozen lines. IBC CODE 14.3.4; Rectify Prior to Departure; to the satisfaction of the Administration and the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
Resolution: Flag report recieved to the satisfaction of the Coast Guard.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 20 January 2024 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed leak in forward steam line; 74 SOLAS 04 II-1/33.1; Rectify prior to departure; To the satisfaction of Administration and Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2024
Resolved 20 January 2024
Resolution: Flag report recieved to the satisfaction of the Coast Guard.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 25 February 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2019
Resolved 26 February 2019
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 25 February 2019 Resolved
The Inert Gas System shall be capable of inerting each tank to a level at which combustion cannot be supported. Vessel's crew could not demostrate proper operation of the Inert Gas Generator. 74SOLAS(2001)II-2/62.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 22 March 2019
Resolution: Received class report attesting to the repairs. See documents.
01 - Certificates & Documentation › 013 - Documents › Cargo record book
Issued 25 February 2019 Resolved
After completion of any NLS cargo operation, the operation shall be promptly recorded in the cargo record book. The February 9th loading of Urea Solution and Urea Ammonium Nitrate Solution were not recorded in the cargo record book. MARPOL II/15.2
Action required: 10 - Deficiency Rectified
Due 25 February 2019
Resolved 25 February 2019
Resolution: [name withheld] corrected cargo record book log entries on the spot with documented quick notes he took during the February 9th loading.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 February 2019 Resolved
The owner of a foreign flag vessel wishing to have the Coast Guard conduct a Certificate of Compliance (COC) examination must proceed as follows: (a) Notify the Officer in Charge, Marine Inspection of the port where the vessel is to be inspected at least 7 days before the vessel arrives and arrange the exact time and other details of the examination.
Action required: 10 - Deficiency Rectified
Due 26 February 2019
Resolved 26 February 2019
Resolution: Exam conducted. Vessel issued LOW.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 1 March 2018 Resolved
Vessel current CSR #10 Amendments does not accurately reflect the vessel's Document of Compliance (ISM-DOC) audit authority. Vessel's DOC is issued by Liberia with an audit conducted by DNV-GL. Current CSR reflects DOC was issued by Liberia with an audit by Lloyds Register. SOLAS (2014) CH XI-1/Reg 5.3.12
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 3 March 2018
Resolution: Vessel was issued a new CSR to reflect changes
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 24 February 2017 Resolved
1899 - The IGS shall be capable of delivering IG with O2 content of not more than 5% by volume in the IG supply main to the cargo tanks at any required rate of flow. During operational test of the IGG, the O2 analyzer displayed 0.0% due to the high concentration of soot after the scrubber. Ship could not prove inert gas was not more than 5% by volume. 74 SOLAS (01) II-2/62.3.2 17AC
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 28 February 2017
Resolution: SEC HOU-GAL PSC received a class report from Lloyd's attesting to the repair and proper operation of the entire IGG system.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 24 February 2017 Resolved
1899 - Special consideration shall be given to the design and location of scrubber and blowers with relevant piping and fittings in order to prevent flue gas leakages into enclosed spaces. IG main line after gas regulating valve IWO start air receivers is wasted and would not prevent flue gas from leaking into the engine room. 74 SOLAS II-2/62.8.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 28 February 2017
Resolution: SEC HOU-GAL PSC received a class report from Lloyd's attesting to the repair and proper operation of the entire IGG system.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 24 February 2017 Resolved
1840 - A tank overflow alarm must be audible and visual in that part of the deck where the containment systems are located and at the point where cargo loading is controlled on the tankship. The audible alarm was not working on deck during the exam. Crew repaired prior to completion of exam. 46 CFR 153.408(e) 10C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2017
Resolved 24 February 2017
Resolution: Crew repaired prior to completion of exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.