ENERGOS PRINCESS is a 2003 tank ship. The Coast Guard has recorded 11 inspections since 2016, most recently in September 2025, along with 2 deficiencies and 4 operational controls, 1 with no removal date recorded.
Records from 2016 to 2025. Most recent: inspection, 30 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it93899 - Convention (Subpart B), Gross Ton 93899 - Simplified, Gross Ton 18170 - Convention (Subpart B), Net Ton 107046 - Displacement, Metric Ton 77707 - Dead Weight, Metric Ton 28170 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
11 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
30 September 2025Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8244373
17 July 2025COC-GAS Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8177960
4 April 2024Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7889789
5 March 2024COC-GAS Renew · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7872040
16 October 2022COC-GAS Renew · Ballast Water Examination
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 March 2024Resolved
THE PURPOSE OF THIS REGULATION IS TO MAINTAIN AND MONITOR THE EFFECTIVENESS OF THE FIRE SAFETY MEASURES THE SHIP IS PROVIDED WITH. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: FIRE PROTECTION SYSTEMS AND FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. ; THE ACTIVIATION BOTTLES FOR THE CO2 SYSTEM ARE INSTALLED WITHIN A LOCKED BOX, TO WHICH, THE SHIP'S PERSONNEL COULD NOT PRODUCE THE KEY TO UNLOCK FOR ACCESS TO THE ACTIVATION BOTTLE. (74 SOLAS II-2/14.1.1)
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 11 March 2024
Resolved 7 March 2024
Resolution: KEY WAS CREATED FOR ACCESSING FIRE CO2 CONTROL CYLINDER BOX AND STORED PROPERLY IN BREAK-GLASS RECEPTABLE NEXT TO CABINET.
Fire Fighting › Nozzles › Condition
Issued 29 March 2016Resolved
On ships carrying flammable or toxic products or both, a water-spray system for cooling, fire protection, and crew protection should be installed. PSCOs observed numerous deck water spray nozzles did not adequately provide water coverage at the following locations: Cargo compressor room, cargo macinery room, and deck house facing the cargo area.
SOLAS 74 (14Cons.)VII/Reg 13.1,IGC Code 11.3.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 30 March 2016
Resolution: Attend the vessel and cleared the deficiency issued on 29MAR2016. Nozzels were found to contain mud from the river and which prevented adequate water coverage. Witness operation of the deck spray using fresh water. All Sat.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.