04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 March 2021
Resolved
Bilge system not working properly. Must have audio and visual indicators/alarms for each hight water alarm and a visual indicator for each automatic bilge pump when operating. Make repairs to all bilge pumps/alarms and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 2 March 2021
Resolution: Vessel installed all new wiring, bilge pumps and alarms. Tested SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 March 2021
No resolution recorded
MDE is missing the front guard over the belts and pulleys. Must have guard to protect from rotating machinery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 March 2021
Resolved
The FCC safety certificate expired Jan 2021. Must have certified FCC inspector come out and re certify radio equipment.
47 CFR 13
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 2 March 2021
Resolution: Re certified radio equipment and received FCC safety certificate
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 March 2021
No resolution recorded
First aid kit has expired items. Must replace all expired/missing items to meet requirements in 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 March 2021
No resolution recorded
Life Float has D.O.T. retro tape instead of the SOLAS as required. Must replace all retro tape with SOLAS tape. Vessel is restricted to day light hours only until fixed and cleared by the CG.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 March 2021
No resolution recorded
Life Float looked to have been spray painted with orange paint, which is an un approved repair. Must make approved repair in accordance with manufacture using international orange paint.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 March 2021
Resolved
Compass light is not working. Must make repairs to compass and test with CG Marine Inspector. Vessel is restricted to daylight hours only until fixed and cleared by CG.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 2 March 2021
Resolution: Light was repaired and tested SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 March 2021
No resolution recorded
Vessel does not have a crew training log and not properly logging fire drills and MOB drills. Need to make new log for crew training, and Fire and MOB drills.
46 CFR 185.420
46 CFR 185.520
46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 1 March 2021
Resolved
Vessel had 3 expired flares onboard. Must have at least 6 red and 6 orange or 12 red flares. Must replace expired flares prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 1 March 2021
Resolution: Went to store and bought new flares
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 March 2021
Resolved
Life float light was found to have a broken clip used to secure light to buoy. Must replace quick release clip with CG approved clip. Vessel restricted to daylight hours only until fixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 1 March 2021
Resolution: Went to store and bought new clip and re spliced to line.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 March 2021
No resolution recorded
Alcohol Swabs were expired, no proof of being able to test for Alcohol after a marine casualty. Plan is to one of the local dive shops meet at the dock if a marine casualty was to happen until they order new swabs.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 March 2021
Resolved
Anchor light was not working properly. Forward side was working but after was not. Must make repairs prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 2 March 2021
Resolution: All NAV lights were tested, SAT
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 March 2021
Resolved
EPIRB registration expired Jan 2018. Also EPIRB did not work when trying to test. Must Repair/Replace EPIRB and registrator. Vessel restricted to 3 miles from shore until fixed and cleared by the CG
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 2 March 2021
Resolution: Repairss were done and re registered. All SAT
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 January 2020
Resolved
Provide visual indicators at operating station for bilge high level alarms for all required spaces (forward, engineer room, fuel tank).
Action required: 705 - Other - as specified
Due 28 January 2020
Resolved 27 January 2020
Resolution: Lights installed for all 3 compartments
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 21 January 2020
Resolved
Demonstrate proper closure of Port Engine room ventilation, space is equipped with fixed fire fighting extinguishing system.
Action required: 705 - Other - as specified
Due 28 January 2020
Resolved 27 January 2020
Resolution: Corrected, latches and stays completely closed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 January 2020
Resolved
Provide metal supports with rubber insulation for chaffing in Engine compartment for electrical wires/cables at intervals of 18 inches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 2 March 2020
Resolution: Supports provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 January 2020
Resolved
Provide means to accurately gauge Port and STBD fuel tanks, sending units not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 February 2020
Resolution: New gauge installed on STBD tank.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2020
Resolved
Register vessel with state of Florida, provide proof of current registration.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2020
Resolution: Registered with FL
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 January 2020
Resolved
Provide valid FCC station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 January 2020
Resolution: Provided.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 26 November 2019
Resolved
Provide access to port side fuel tank for inspection by April 30, 2020. Contact local Coast Guard Marine Inspector for reinspection.
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 13 February 2020
Resolution: Vessel owner informed inspector that she had taken the port tank out of service (condemened it) and would let us know when she had the time and funds to replace.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2019
Resolved
Replace clear hydraulic hose with a hose that meets SAE J-1942.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2019
Resolved 26 November 2019
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 January 2018
Resolved
Vessel COD is expired and must be renewed prior to any operations.
Action required: 10 - Deficiency Rectified
Resolved 8 February 2018
Resolution: New COD was provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 January 2018
Resolved
Fire boy audible alarm is inoperable. Repair /renew alarm.
Action required: 10 - Deficiency Rectified
Resolved 8 February 2018
Resolution: New alarm head unit was installed and tested all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 January 2018
Resolved
Both AC and DC panels have openings, and must be enclosed to prevent electrical shock.
Action required: 10 - Deficiency Rectified
Resolved 8 February 2018
Resolution: Both panels were properly enclosed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 January 2018
Resolved
Vessel does not have a log book for survival craft maintenance. Provide monthly log.
Action required: 10 - Deficiency Rectified
Resolved 8 February 2018
Resolution: New log was created.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 January 2018
Resolved
during inspection there wa no crew available for drills. Provide crew and conduct drill with CG inspector
Action required: 10 - Deficiency Rectified
Resolved 8 February 2018
Resolution: Drills were conducted.
Lifesaving › Lifefloat › Retroreflective Material
Issued 25 January 2017
Resolved
Life float is missing some retro tape and needs new grablines.
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 10 February 2017
Resolution: Retro and grablines were renewed.
Documentation › Certificates/Documents › FCC SSL
Issued 25 January 2017
Resolved
FCC station license was not valid.
Action required: 705 - Other - as specified
Due 8 February 2017
Resolved 10 February 2017
Resolution: New FCC station license was provided.
Construction/Loadline › Hull › Side Shell
Issued 4 February 2016
Resolved
Condition: Damaged By Earlier Event
Due 22 February 2016
Resolved 22 February 2016