MTM MUMBAI

MTM MUMBAI is a 2003 tank ship. The Coast Guard has recorded 49 inspections since 2003, most recently in February 2023, along with 19 deficiencies and 9 operational controls.

Records from 2003 to 2023. Most recent: inspection, 8 February 2023.

Built
2003
Last inspected
8 February 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9242338 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V2085
656938
Flag
SINGAPORE
—
Maury page id
psix-656938

Inspections, by type

…with no type recorded19
Years with a record 16 calendar years (2003–2023)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29200 - Regulatory (Subpart C or D), Gross Ton
29220 - Convention (Subpart B), Gross Ton
11943 - Regulatory (Subpart C or D), Net Ton
54417 - Displacement, Ton
44996 - Dead Weight, Ton
11943 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 49

8 February 2023 Deficiency Check · COC-CHEM Renew · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7629236
7 February 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7633118
5 November 2021 In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7345864
9 August 2021 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7281203
17 September 2019 COC-CHEM & TVE Annual · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6809196
15 September 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6813121
2 July 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6733775
24 August 2018 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6521753
17 December 2017 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6325535
16 August 2017 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6242192
16 August 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6274903
24 March 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6110082
23 May 2016 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5886253
21 May 2016 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5910614
23 February 2016 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5816830
15 February 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4244667
15 February 2012 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4244834
26 September 2011 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4154774
19 October 2010 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3867280
28 December 2009 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3655828
20 November 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3366493
24 October 2008 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex II Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3350534
22 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3275652
14 March 2008 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3164847
15 November 2007 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3094185
5 November 2007 COC-CHEM Renew · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3093105
18 October 2007 Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3082276
30 January 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2864340
29 January 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2863231
16 January 2007 Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2857189
2 May 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2638417
1 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2637472
20 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2537865
4 November 2005 COC-CHEM Renew · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2528221
15 August 2005 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2464259
18 June 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2399932
15 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2391551
19 October 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2224193
18 October 2004 Random ISPS/MTSA/PSC
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2223714
1 October 2004 COC-CHEM Annual
Type not classified · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2210745
8 July 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2126159
18 February 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2008882
17 February 2004 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2007892
8 December 2003 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1960644
15 November 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1947625
14 November 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1947781
30 October 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1938809
16 October 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1929842
16 October 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1932406

Deficiency record · 19

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 8 February 2023 Resolved
Ships carrying flammable products shall be equipped with at least two instruments designed and calibrated for testing for specific vapors in question. Both of the vessel's portable instruments would not calibrate according to the specifications of the span gas.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 9 February 2023
Resolution: Received class survey report attesting to the satisfactory calibration of both portable instruments by an authorized technician.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 August 2021 Resolved
Vessel's vapor recovery line was incorrectly painted.
Action required: 10 - Deficiency Rectified
Due 14 August 2021
Resolved 14 August 2021
Resolution: Vessel painted the vapor recovery line
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 17 September 2019 Resolved
The inert gas shall be designed to be capable of rendering and maintaining the atmosphere of the relevant cargo tanks non-flammable. PSCO observed the inert gas generator unable to start after shut down tests were conducted. A burner failure alarm would activate each time the crew would attempt to start the IGG. 74SOLAS(04)II-2/4.5.5.1.1, FSS Code 15.2.2.1.1 17c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2019
Resolved 17 September 2019
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 September 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The arrangements for the storage, distribution, and utilization of oil used in pressurized systems shall be such as to ensure the safety of the ship and persons onboard. PSCO discovered lube oil leak on #1 generator. 74SOLAS(04)II-2/4.2.3.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2019
Resolved 17 September 2019
Resolution: Deficiency was cleared by class.
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Pilot (air start)
Issued 15 February 2012 Resolved
Vessel experienced a loss of propulsion due to faulty main start air valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2012
Resolution: Vessel overhauled start air valves and tested propulsion forward and astern.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 19 October 2010 Resolved
Vessel span gas used for calibration of the fixed O2 measurement instrument for the IGG system expired May 2007. To the satisfaction of the attending classification society surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2010
Resolution: Received receipt of purchase for span gas.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 19 October 2010 Resolved
Vessel line throwing appliances expired October 2008. To the satisfaction of the attending classification society surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2010
Resolution: Received receipt of purchase for 4 line throwing devices.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 19 October 2010 Resolved
Found separated welds for the studs in two of the anchor chain linkages on both the port and starboard side anchors. To the satisfaction of the attending classification society surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2010
Resolution: Vessel issued an outstanding condition of class for JAN2011 for repair of the port and starboard anchor.
Lifesaving › Emergency Outfit › Protective Clothing
Issued 19 October 2010 Resolved
Vessel does not carry on board three complete sets of safety equipment as required. To the satisfaction of the attending classification society surveyor.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 October 2010
Resolution: Received class survey report that vessel''s does not carry cargoes that require the safety equipment (Chemical Suits).
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 24 October 2008 Resolved
[name withheld] could not display proper operation of Fixed Gas Detector System for measuring Lower Explosive Limits. Provide proof of [name withheld] receiving proper training in calibrating the system to the satisfaction of the Administration.
Action required: 705 - Other - as specified
Due 24 November 2008
Resolved 11 November 2008
Resolution: Rcvd fax from Company stating that [name withheld] demonstrated proper competence in calibrating both portable and fixed gas meters. Deficiency cleared. [name withheld]
Deck/Cargo › Cargo Stowage › General
Issued 24 October 2008 Resolved
Ship's portable instruments for measuring oxygen and flammable vapour concentrations are only capable of testing oxygen in cargo tanks not ballast tanks. Acquire new meters and provide proof of proper calibration prior to departure to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2008
Resolution: Rcvd fax of meters from shipping agency, meters meet all requirements.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 March 2008 Resolved
Vessel's secondary radar system is inoperative. Vessel is to make proper repairs to effected equipment and provide technicians report to local OCMI prior to departure from Port of Freeport, TX
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2008
Resolution: Received technician''s report satisfying requirement of 14MAR2008 Op Control. Secondary Marine Radar System is now working normally on all ranges. All radar and ARPA functions are proper.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 5 November 2007 Resolved
Vessel could not provide evidence of the breathing apparatus having been tested and inspection by an expert at least once a year.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 November 2007
Resolution: Attended vessel and verified annual inspection of breathing apparatus.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 October 2007 Resolved
X- BAND RADAR NOT WORKING
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2007
Resolution: RADAR REPAIRED
Construction/Loadline › Markings › Load Line Mark
Issued 4 November 2005 Resolved
Vessel's load line marking is rusted and not of contrasting color to the hull. Vessel must repaint the correct load line to ensure that is match's the Load line Certificate.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 20 November 2005
Resolution: Received Master statement via fax that load lines had been painted.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 17 February 2004 Resolved
M/V GALAHAD failed to provide proper advanced notice of arrival prior to entering the Port of Charleston.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 17 February 2004
Resolved 17 February 2004
Resolution: M/V GALAHAD provided proper advanced notice of arrival prior to entering the Port of Charleston.
Engineering › Steering Gear System
Issued 14 November 2003 Resolved
Vessel's main steering gear not operating properly. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 November 2003
Resolved 15 November 2003
Resolution: Received class report attesting to satisfactory repair and operation.
Pollution Prevention/Response › Prevention Equipment
Issued 16 October 2003 Resolved
PRIOR TO LOADING IN U.S. PROVE PROPER OPERATION OF ALL STARBOARD TANK OVERFILL ALARMS. LEGACY COMPONENT DESC: Overfill Devices
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 November 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 16 October 2003 Resolved
PROVE THAT ALL CARGO HOSES HAVE BEEN PRESSURE TESTED TO 1.5 MAWP.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.