MAURY USCG vessel records Sign in
← All vessels

SPLENDID ACE

SPLENDID ACE is a 2003 freight ship. The Coast Guard has recorded 38 inspections since 2003, most recently in May 2026, along with 10 deficiencies and 1 operational control.

Records from 2003 to 2026. Most recent: inspection, 26 May 2026.

Built
2003
Last inspected
26 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9252228 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
657002
Flag
JAPAN
—
Maury page id
psix-657002

Inspections, by type

…with no type recorded6
Years with a record 18 calendar years (2003–2026)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it56556 - Convention (Subpart B), Gross Ton
18502 - Convention (Subpart B), Net Ton
19879 - Dead Weight, Ton
34528 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

26 May 2026 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8380760
12 November 2025 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8265174
17 October 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7809803
10 October 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7571213
8 November 2021 PSC B · MARPOL Annex VI Survey · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7347117
13 July 2020 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6999748
14 March 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6926517
24 January 2020 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6895454
16 December 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6871106
9 May 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6678870
4 September 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6531516
8 June 2017 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6170266
13 April 2017 ISPS III Exam · In-Service Inspection · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6124016
13 April 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6205197
24 February 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6094107
17 October 2016 ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6023592
11 July 2016 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5934745
7 July 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5932892
4 May 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5862909
16 October 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5001365
19 July 2012 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4383464
3 July 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4364740
7 January 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3919501
13 December 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3115104
6 November 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3093667
17 October 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2802665
31 March 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2613413
4 October 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2507727
19 August 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2468078
17 August 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2466460
28 May 2005 In-Service Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2467492
7 February 2005 PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2288248
29 December 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2266265
24 November 2004 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2247504
16 September 2004 Random ISPS/MTSA/PSC
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2197341
14 August 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2166166
28 June 2004 ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2110126
14 October 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1928290

Deficiency record · 10

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 December 2019 Resolved
The machinery and associated piping system shall be of a design and construction adequate for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed 06 ratchet straps securing F/O line to MDE for added support do to vibration. 74 SOLAS(04) II-1/26.1 40ac
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 January 2020
Resolution: Received report and photos from vessel attesting to permanent repairs of the MDE fuel line supports.
Engineering › Steering Gear System › Power Unit
Issued 8 June 2017 Resolved
WHEN A MAIN STEERING GEAR SYSTEM IS COMPRISED OF TWO OR MORE POWER UNITS, AND AUXILIARY SYSTEM NEED NOT BE FITTED, PROVIDED THAT THE MAIN STEERING SYSTEM IS ARRANGED THAT AFTER A SINGLE FAILURE IN ONE OF THE POWER UNITS THE DEFECT CAN BE ISOLATED SO THAT STEERING CAPABILITY CAN BE MAINTAINED OR SPEEDILY REGAINED. STEERING GEAR SYSTEM #2 FAILED TO OPERATE DURING DEPARTURE TESTS AND IS CURRENTLY...
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2017
Resolution: Received class and tech reports attesting to the repair and satisfactory working condition of the steering system
Engineering › Compressed Air System (start air) › Valve
Issued 13 April 2017 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel lost propulsion while completing mooring evolution. Crew determined the #4 starting air valve/pilot air line union failed. Permanent repairs were made and CG observed satisfactory test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 April 2017
Resolution: Union was replaced and test was completed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 May 2016 Resolved
1730 - Oily Water Seperating Equipment - The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. Effluent continues to discharge overboard after oil content exceeds 15ppm. MARPOL I/14.7
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Ship was able to repair valve to proper operating condition.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 May 2016 Resolved
0950 - Electric Equipment in General - All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Newly installed security monitoring system is installed with exposed electrical connections unsecured on deck in steering gear room. 74 SOLAS 2004 con. II-1/45.1.3
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 15 May 2016
Resolution: Recieved report attesting to repair of battery storage box and secured wiring.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 4 May 2016 Resolved
0799 - Other - The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met:the fire integrity of divisions shall be maintained at openings and penetrations. Newly installed wiring penetrating fire boundary was resealed with non-fire retardent materials. 74 SOLAS(14) II-2/9.1.3
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 4 May 2016
Resolution: Replaced with A-60 fire retardent putty.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 3 July 2012 Resolved
The machinery and associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended. Following discrepancies found: 1. Incinerator frame bent. 2. 10cm crack on upper left corner of lower chamber. 3. insulation coming off or missing on fuel piping. (40ab)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 July 2012
Resolved 19 July 2012
Resolution: NKK issued class report attesting to repairs. See attached.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 3 July 2012 Resolved
The machinery, other pressure vessels, and associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended. Hole found on top of sewage processing tank.(40ab)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 July 2012
Resolved 19 July 2012
Resolution: NKK issued class report attesting to repairs. See attached.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 3 July 2012 Resolved
The SOPEP shall consist at least of the procedures and point of contact on the ship for coordinating shipboard action with national and local authorities. The vessel is missing local contact numbers for visiting ports. (10c)
Action required: 705 - Other - as specified
Due 3 July 2012
Resolved 3 July 2012
Resolution: Discussed with Captain and chief officer about local numbers that must be added.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 3 July 2012 Resolved
The firefighting and SOLAS training manual shall be specific to the vessel in accordance to the manuals and instructions. Both manuals contain information that is not specific to the firefighting and life saving appliances onboard the ship.(10c)
Action required: 705 - Other - as specified
Due 3 July 2012
Resolved 3 July 2012
Resolution: Talked to Captain and [name withheld] about making fire fighting and life saving manuals more specific.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.