← All vessels
NORDIC RUTH
NORDIC RUTH is a 2000 tank ship. The Coast Guard has recorded 36 inspections since 2001, most recently in February 2017, along with 26 deficiencies and 8 operational controls.
Records from 2001 to 2017. Most recent: inspection, 8 February 2017.
- Built
- 2000
- Last inspected
- 8 February 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 26 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9208473 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V2537
6571
Flag
SINGAPORE
—
Maury page id
psix-6571
Inspections, by type
…with no type recorded15
Years with a record
12 calendar years (2001–2017)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8835 - Convention (Subpart B), Net Ton
44304 - Displacement, Ton
35820 - Dead Weight, Ton
23842 - Convention (Subpart B), Gross Ton
44304 - Displacement, Ton
35820 - Dead Weight, Ton
23842 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 36
8 February 2017
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6080830
8 February 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6082791
28 December 2011
Ballast Water Examination · COC-CHEM Renew · ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4214864
9 August 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4110105
20 January 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3929823
16 January 2011
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3927556
19 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3872725
1 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3860967
1 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3863173
13 February 2010
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3679568
4 January 2010
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3658623
8 July 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3528111
6 March 2009
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3428608
26 November 2008
Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3369971
8 November 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3359422
27 January 2008
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3137104
6 December 2007
Ballast Water Examination · ISPS II Exam · COC-CHEM Renew · MARPOL Annex V Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3104176
20 September 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3062257
10 February 2007
Random ISPS/MTSA/PSC · MARPOL Annex II Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2870085
9 February 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2867201
17 October 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2802172
16 October 2006
MARPOL Annex I Examination · COC-CHEM Annual · MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam · ILO-147 Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2801432
5 October 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2794183
5 October 2006
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2794336
30 September 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2790454
8 November 2005
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2530599
13 October 2005
MARPOL Annex II Examination · MARPOL Annex V Examination · COC-CHEM Renew · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2513404
17 June 2004
MTSA/ISPS Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2101084
15 June 2004
MARPOL Annex I Examination · MARPOL Annex V Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2098802
5 January 2004
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1974717
29 December 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1970516
30 October 2002
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1698582
13 May 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1615990
15 February 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 287388
4 January 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 285608
4 January 2001
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 825515
Deficiency record · 26
Navigation › Piloting/Steering › Gyro Compass
Issued 9 August 2011
Resolved
Vessel reported inoperable gyro compass.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 16 January 2011
Resolved
Any certificate required by the Convention must be kept available in its original form on board the ship on which the holder is serving. The master did not have an original copy of his flag state endorsement onboard nor did the second engineer. Both had copies without an dated application to accompany it. STCW 95 I/2.9 (17b)
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 16 January 2011
Resolved
Oil tankers 150 GT and above shall be equipped with an oil discharge monitoring and control system approved by Administration. Vessel was unable to demonstrate proper operation of the system. MARPOL ANNEX I/REG 31.1 (30b)
Lifesaving › Lifeboat › Hatches
Issued 16 January 2011
Resolved
When access to the lifeboat is provided by hatches, hatches are required to make the lifeboat watertight when closed. The starboard lifeboat hatch on the outboard side does not close properly and the bow hatch is leaking rain water into the lifeboat. 74 SOLAS (04 ed) III/31.1.1.1 LSA Code 4.6.2.2 (30a)
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 16 January 2011
Resolved
Each cargo tank of a tankship must be equipped with intrinsically safe high level alarm that alarms before high level alarm but not lower than 95%. Cargo Oil Tanks 2P and 5P were malfunctioning. 46CFR 39.20-17 (17A)
Deck/Cargo › Inert Gas System › IGS Blower
Issued 16 January 2011
Resolved
Tankers of 20,000 DWT and upwards shall be installed with IGS for the protection of the cargo tanks IAW FSS Code. Vessel was unable to demonstrate compliance due to inoperable boiler. SOLAS 74 (04 ed.) II-2/4.5.5.1.1 (17a)
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Combustible Gas Indicator
Issued 16 January 2011
Resolved
Tankers shall be equipped with at least one portable instrument for measuring flammable vapor concentrations and suitable means shall be provided for calibration of such instruments. Vessel was unable to demonstrate proper calibration of portable instruments. 74 SOLAS (04 ed) II-2/4.5.7.1 (17A)
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 January 2011
Resolved
Nautical publications necessary for the intended voyage shall be adequate. Vessel does not have U.S. Coast Pilot on board readily available. 74 SOLAS (04 ed) V/27 / 33CFR164.33(a)(2) (17C)
Lifesaving › Hand Flares › Storage
Issued 16 January 2011
Resolved
Pyrotechnics shall be container in a water resistant contianer. Bridge pyrotechnics are not in a water resistant container. 74 SOLAS (04 ed) III/5.3 / LSA Code 3.1 (17C)
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 16 January 2011
Resolved
Vessel is required to be capable of transmitting and receiving for distress and safety purposes on all safety and distress frequencies when provided with a MF/HF radio installation. Vessel's MF/HF installation has been inoperable since October 2010 and has been incapable of transmitting and receiving distress transmissions. 74 SOLAS (04 ed) IV/10.2.1 (17C)
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 January 2011
Resolved
Each vessel of 10,000 GT or more must have a second marine radar system that operates independent of the first. Vessel's secondary radar was not operable upon Port State Control Inspection. 33 CFR 164.37(a)
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 January 2011
Resolved
Vessel shall have decontamination showers and eye wash stations on deck and shall be operational in all ambient conditions. Two deck showers were tested and neither were found readily available for use due to the closure of isolation valves. 74 SOLAS (04) VII/10.1 / IBC Ch.14.3.4 (10c)
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pressure/Vacuum Relief Valve
Issued 16 January 2011
Resolved
A secondary means of allowing full flow relief of vapor, air, or inert gas mixtures shall be provided to prevent over-pressure or under pressure in the event of failure of the arrangement of P/V valve. Vessel's crew was unable to demonstrate proper operational testing of pressure vacuum alarms.74 SOLAS (04 ed) II-2/II.6.3.2 (17a)
Construction/Loadline › Markings › Load Line Mark
Issued 4 January 2010
Resolved
Deck line is painted the same color as the hull. The vessel's load line marks painting is also worn off.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 January 2010
Resolved
Vessel's port side hand rails in the vicinity of fendering equipment are crushed.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 4 January 2010
Resolved
Vessel's incinerator is missing the blower's shield/cover, preventing the incinerator from effectively operating as designed. MARPOL 73/78, Annex VI, Reg. 16
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 4 January 2010
Resolved
Vessel's high level alarms on the #2 starboard and #5 port cargo tanks are inoperative. Vessel shall make repairs to the satisfaction of the certificate issuing authority prior to loading cargo.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 4 January 2010
Resolved
Vessel failed to provide a second source of energy for starting the emergency generator due to the generator's batteries being inoperative.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 July 2009
Resolved
Received Inbound Letter of Deviation for Inoperable Primary Marine Radar. Prior to departure vessel must submit a tech report attesting to the proper operation of the radar.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 November 2008
Resolved
The vessel secondary radar is not operable. The is required to submit a tech report attesting to the proper operation of the secondary radar.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 6 December 2007
Resolved
Ensure proper operation of hi-level & overfill warning system for tanks 1P and 2S. May provide statement from class or flag to CG to show completion, or have local CG Marine Inspector verify.
Deck/Cargo › Cargo Heating › General
Issued 6 December 2007
Resolved
Make permanent repairs to steam lines on cargo deck where leaks exist. May provide a statement from class or flag to show completion, or have local CG Marine Inspector verify with cargo heating system running. Two leaks observed on steam main line adjacent to catwalk: (1) IVO Pt slop; (2) IVO #5 Pt.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 16 October 2006
Resolved
While conducting deck walk completed random sampling of cargo tanks, found 6S 15.8%, 2S 15.7%, 1P 10.5%. FSS Code requires tanks to be below 8% at tank and under pressure. Have ship start IG system and have tanks brought below 8% Oxygen at tanks. SOLAS 74/2004 II-2/4, FSS Code Chap 15, 2.1.3.2. Issued NOV for Failure to maintain adequate IG on tanks.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 October 2006
Resolved
Ships Oily Water Separator has a pin hole leak on the discharge line to the overboard valve. Make permanent repairs to the satisfaction of class.
Fire Fighting › Fire Hydrants › Location/Position
Issued 13 October 2005
Resolved
Found fire hydrant being blocked by a pipe storage rack in the Inert Gas Room, "A" Deck, frame #21. Remove pipe rack or relocate hydrant.
Deck/Cargo
Issued 4 January 2001
Resolved
Vessel to have on board sufficient O2 botles to calibrate IGS O2(calibration) analyser and hand portable O2 meters Prior to next U.S. Port, after departing Puert Rico.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.