Records from 2003 to 2018. Most recent: operational control imposed, 7 March 2018.
Inspection history · 19
7 March 2018
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6367583
27 February 2018
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6362796
3 June 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6159429
27 May 2016
Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5879452
15 August 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5216528
16 March 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4817072
3 March 2014
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4800936
7 February 2012
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4252687
13 January 2011
ISPS I Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3920602
12 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3920601
5 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3921350
30 September 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3335583
16 February 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3148445
4 August 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2156174
28 July 2004
ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2148348
29 December 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1980600
23 October 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1934701
21 October 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1934985
20 October 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1936025
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 3 June 2017
Resolved
9900 - To discharge ballast water into waters of the U.S., a vessel subject to 151.2025 of this subpart must either ensure that the BW meets the BW discharge standard as defined in 151.2030(a) to the schedule in paragraph (b). The vessel did not utilize a Coast Guard approved BWMS or AMS to treat BW before discharging into U.S. waters. The vessel is beyond its compliance date. 33 CFR 151.2035-40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 June 2017
Resolved 27 February 2018
Resolution: Vessel received extended compliance date from CG-OES.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 27 May 2016
Resolved
0750 - Fire Prevention - "A" Class Divisions shall be so constructed as to be capable of preventing the passage of smoke and flame. Penetrations were made in the B, C, and D deck cable trunks for WiFi installation, which allow for the passage of smoke. SOLAS 74 (2001 Cons.) II-2/3.3 - 16AC
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 28 May 2016
Resolution: Received ABS Class surveyor report attesting to the satisfactory repairs carried out to the compromised electrical penetrations on the B, C, and D deck cable trunks.
Documentation › Logs/Records › Oil Record Book
Issued 13 January 2011
Resolved
1710 - Oil record book - Oil record book part I shall be completed from a tank to tank basis, whenever the following takes place in the engine room: collection and disposal of oil residues. The oil record book is showing the incinerator exceeding its maximum burn rate in accordance with the IOPP form A. - MARPOL 2006 cons. I/16
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 June 2011
Resolution: Vessel provided class report stating that the previous IOPP supplemental form was stating the incorrect information. Class issued a new IOPP Certificate with the correct maximum capacity for the incinerator at 360 kW instead of 30 Lh. Deficiency Clear.