MAURY USCG vessel records Sign in
← All vessels

REEF CLEANER

REEF CLEANER is a 2003 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2003, most recently in August 2018, along with 46 deficiencies — 6 with no resolution recorded — and 1 casualty investigation in 2016.

Records from 2003 to 2018. Most recent: inspection, 2 August 2018.

Built
2003
Last inspected
2 August 2018
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI2307
658062
Flag
UNITED STATES
366936570, 367197850, 367676840, 367712970 (licence lapsed)
Maury page id
psix-658062

Inspections, by type

…with no type recorded2
…past their stated due date6
Years with a record 12 calendar years (2003–2018)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INC · FT PIERCE, FL, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPENSACOLA, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI5883MMSI 367712970 · expired · compulsorily equipped · granted 2 February 2016, cancelled 4 April 2026
WDI2307MMSI 367676840 · expired · compulsorily equipped · granted 5 June 2015, cancelled 12 July 2025
WDD8334MMSI 367197850 · expired · compulsorily equipped · granted 20 June 2007, cancelled 26 August 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDB7111MMSI 366936570 · expired · compulsorily equipped · granted 3 April 2004, cancelled 7 June 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 19

2 August 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6498854
20 October 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6291886
23 October 2016 Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 6027886
23 October 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6029642
13 July 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5939706
16 June 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5909715
14 March 2016 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5841692
24 May 2012 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4319042
1 August 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4098280
15 July 2009 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3530219
20 February 2009 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3421041
18 June 2008 COI Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3234786
18 June 2007 Deficiency Check · In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3019628
11 May 2007 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2927183
21 April 2006 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2629345
7 February 2006 Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2580794
24 June 2005 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2399096
9 February 2004 Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1989171
30 December 2003 Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1971335

Deficiency record · 46

Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 October 2017 No resolution recorded
PFD instructions do not match PFDs stored onboard vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Personnel › Training › Medical, Person in Charge/Management
Issued 31 October 2017 No resolution recorded
Master of vessel had not taken DAPI supervisor training IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Interface Detector
Issued 31 October 2017 Resolved
Machinery space high water bilge alarm inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 31 October 2017
Resolution: Procured and installed new bilge alarm float switch.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 31 October 2017 No resolution recorded
No emergency instruction placed at the operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Documentation › Markings/Placards › Warning Signs
Issued 31 October 2017 No resolution recorded
No employee assistance hotline numbers posted IAW 46 CFR 16.401.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Hose
Issued 31 October 2017 No resolution recorded
Fwd bilge pump discharge line protruding through fwd watertight bulkhead in space; discharge line must discharge in same space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2018 — due date passed with no resolution recorded
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 31 October 2017 No resolution recorded
Buoyant apparatus' must be secured together if using one weak link, fitted with type II reto reflective tape, and lines need securing with weak link (breakable) securing device.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 June 2016 Resolved
Unable to produce COD. Provide proper documentation
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 22 June 2016
Resolution: Provided proper COD.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 June 2016 Resolved
Waterlight battery expired. Replace with proper and updated battery
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 22 June 2016
Resolution: Replaced battery.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 June 2016 Resolved
Fire extinguisher at operating station not serviced up to date. Replace fire extinguisher
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 22 June 2016
Resolution: Replaced fire extinguisher with new one.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 June 2016 Resolved
Bilge indication light inoperable make operable. Make periodic rounds until repaired
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 13 July 2016
Resolution: All bilge operation indicator lights operational.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 22 June 2016 Resolved
Provide documentation of supervisory training for master
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 14 July 2016
Resolution: Proof of completion of supervisor training completed.
Lifesaving › Lifefloat › Paddle
Issued 22 June 2016 Resolved
Paddles were not lashes to lifefloat secure paddle to life float
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 22 June 2016
Resolution: Paddles were secured to life float.
Navigation › Piloting/Steering › Marine Charts
Issued 22 June 2016 Resolved
Marine charts need to be updated
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 13 July 2016
Resolution: All charts made current.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 June 2016 Resolved
Downing placard needs to be updated with all life jacket downing instructions
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 14 July 2016
Resolution: Donning placard for life jackets posted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 15 July 2009 Resolved
Replace (03) B-II devices. Noted to be excessively pitted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2009
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 15 July 2009 Resolved
Replace (06) Child PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 July 2009 Resolved
Replace raw water hose between hull and strainer.
Action required: 705 - Other - as specified
Due 15 August 2009
Resolved 16 July 2009
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 July 2009 Resolved
Provide a 18' painter for light vs the 3' observed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2009
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 18 June 2008 Resolved
Replace sewage and raw water intake valves.
Due 18 June 2008
Resolved 19 June 2008
Construction/Loadline › Hull › Weld
Issued 18 June 2008 Resolved
Reweld bow rail - (forward two weldments).
Due 18 June 2008
Resolved 19 June 2008
Communications › Radio Communications › EPIRB
Issued 18 June 2007 Resolved
Register EPIRB with new Operator information. 46CFR180
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2007
Documentation › Certificates/Documents › FCC SSL
Issued 18 June 2007 Resolved
Obtain new FCC Station License.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2007
Navigation › Piloting/Steering › Marine Charts
Issued 18 June 2007 Resolved
Obtain Coast Pilot, Tides, Light List and Charts for new area of operation. COLREGS
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2007
Stability › Unintentional Flooding › General
Issued 18 June 2007 Resolved
Free up all thru-hull valves. 46CFR176
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 18 June 2007 Resolved
Obtain new pin for Fire Boy System as old one is wasted in place. 46CFR181
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2007
Lifesaving › Hand Flares › Quantity
Issued 18 June 2007 Resolved
Obtain (6) smoke flares. 46CFR180
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 18 June 2007 Resolved
Generate a ship's log and conduct required drills. 46CFR185
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2007
Communications › Radio Communications › EPIRB
Issued 18 June 2007 Resolved
Replace expired hydrostatic release for EPIRB. 46CFR180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2007
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 11 May 2007 Resolved
Provide 07 lights to adult lifejackets. Vessel is restricted to 15 total adults onboard until corrected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 May 2007 Resolved
Repair stern light prior to night operation.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 14 May 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 May 2007 Resolved
Provide 01 waterlight for lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Lifesaving › Lifefloat › Paddle
Issued 11 May 2007 Resolved
Provide 02 paddles for one lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Operations/Management › Drills/Instruction › Fire
Issued 11 May 2007 Resolved
Upon sale of vessel and prior to carriage of passenders contact the local OCMI and conduct a New to Zone inspection and drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2007
Resolution: MSD Panama City conducted NTZ inspection and ran satisfactory drills. See Activity #: 3019628
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 May 2007 Resolved
Provide 01 waterlight for ring lifebuoy.
Condition: Improper/Lack of Maintenance
Due 18 May 2007
Resolved 14 May 2007
Communications › Radio Communications › EPIRB
Issued 21 April 2006 Resolved
Prior to operating past your Limited Coastwise route, provide a new EPIRB battery. They have life floats to operate on a LC route, but not enough to opertate on there Oceans route.
Condition: Improper/Lack of Maintenance
Due 21 April 2006
Resolved 26 April 2006
Resolution: RECEIVED COPY OF RECEIPT FOR BATTERY.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 April 2006 Resolved
Prior to the carriage of passengers, provide a copy of your Documentation. POC left all paper work at his house, which is 40 minutes away.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 26 April 2006
Resolution: POC HAS ORDERED A NEW ONE FROM DOC OFFICE. THIS INSPECTOR HAS CONFIRMED DOC IS VALED.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 April 2006 Resolved
Prior to the carriage of passengers, provide copies of the last year drill log and EPIRB log. POC left all paper work at his house, which is 40 minutes away.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 26 April 2006
Resolution: RCVD COPIES OF LOGS.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 21 April 2006 Resolved
Prior to the carriage of passengers, provide copies of last years portable fire extinguisher inspection log. POC left all paper work at his house which is 40 minutes away.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 26 April 2006
Resolution: RCVD A LETTER SIGNED MY POC ATTESTING TO EXTINGUISHER INSPECTION.
Documentation › Certificates/Documents › FCC SSL
Issued 24 June 2005 Resolved
PROVIDE FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Due 24 July 2005
Resolved 14 July 2005
Resolution: SAT.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 24 June 2005 Resolved
PROVIDE APCA CHEMICAL TESTING PROGRAM OUTLINE INCLUDING TRAINING PAMPHLETS AND EAP.
Due 8 July 2005
Resolved 14 July 2005
Resolution: SAT
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 24 June 2005 Resolved
POST STABILITY LETTER AND COI.
Due 8 July 2005
Resolved 14 July 2005
Resolution: SAT
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 June 2005 Resolved
FALURE TO CONDUCT ANNUAL INSPECTION WITHIN 3 MONTHS BEFORE OR AFTER ANNIVERSARY DATE.
Due 4 February 2006
Resolved 4 February 2006
Resolution: CONDUCTED INSPECTION.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 9 February 2004 Resolved
PROVIDE PERMANENT LOADING MARK PER 46 CFR 185.602 TO CORRESPOND WITH MSC STABILITY LETTER DTD 6JAN2004 AT NEXT DRYDOCK.
Due 19 December 2005
Resolved 7 February 2006
Resolution: Witnessed marking.
Communications
Issued 22 January 2004 Resolved
Provide a FCC Station License and Safety radio Certificate. LEGACY COMPONENT DESC: FCC Lic. & Cert.
Condition: Unknown
Due 9 April 2004
Resolved 29 April 2004
Operations/Management › Drills/Instruction
Issued 22 January 2004 Resolved
Mount your emergency broadcast placard by radio. LEGACY COMPONENT DESC: Emergency broadcast placard
Condition: Improper/Lack of Maintenance
Due 23 February 2004
Resolved 9 February 2004

Casualty record · 1

23 October 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6029642
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record