MAURY USCG vessel records
← All vessels

REEF CLEANER

Built
2003
Last inspected
2 August 2018
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 August 2018
…with no type recorded2
…past their stated due date6
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI2307
658062
Flag
UNITED STATES
Maury page id
psix-658062

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INC · FT PIERCE, FL, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPENSACOLA, FL
Endorsements, as the file codes themcw_un, rec
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 7 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each, 6 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

2 August 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6498854
20 October 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6291886
23 October 2016 Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 6027886
23 October 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6029642
13 July 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5939706
16 June 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5909715
14 March 2016 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5841692

Deficiency record · 15

Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 October 2017 No resolution recorded
PFD instructions do not match PFDs stored onboard vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Personnel › Training › Medical, Person in Charge/Management
Issued 31 October 2017 No resolution recorded
Master of vessel had not taken DAPI supervisor training IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Interface Detector
Issued 31 October 2017 Resolved
Machinery space high water bilge alarm inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 31 October 2017
Resolution: Procured and installed new bilge alarm float switch.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 31 October 2017 No resolution recorded
No emergency instruction placed at the operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Documentation › Markings/Placards › Warning Signs
Issued 31 October 2017 No resolution recorded
No employee assistance hotline numbers posted IAW 46 CFR 16.401.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Hose
Issued 31 October 2017 No resolution recorded
Fwd bilge pump discharge line protruding through fwd watertight bulkhead in space; discharge line must discharge in same space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2018 — due date passed with no resolution recorded
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 31 October 2017 No resolution recorded
Buoyant apparatus' must be secured together if using one weak link, fitted with type II reto reflective tape, and lines need securing with weak link (breakable) securing device.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 June 2016 Resolved
Unable to produce COD. Provide proper documentation
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 22 June 2016
Resolution: Provided proper COD.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 June 2016 Resolved
Waterlight battery expired. Replace with proper and updated battery
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 22 June 2016
Resolution: Replaced battery.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 22 June 2016 Resolved
Fire extinguisher at operating station not serviced up to date. Replace fire extinguisher
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 22 June 2016
Resolution: Replaced fire extinguisher with new one.
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 June 2016 Resolved
Bilge indication light inoperable make operable. Make periodic rounds until repaired
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 13 July 2016
Resolution: All bilge operation indicator lights operational.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 22 June 2016 Resolved
Provide documentation of supervisory training for master
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 14 July 2016
Resolution: Proof of completion of supervisor training completed.
Lifesaving › Lifefloat › Paddle
Issued 22 June 2016 Resolved
Paddles were not lashes to lifefloat secure paddle to life float
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 22 June 2016
Resolution: Paddles were secured to life float.
Navigation › Piloting/Steering › Marine Charts
Issued 22 June 2016 Resolved
Marine charts need to be updated
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 13 July 2016
Resolution: All charts made current.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 June 2016 Resolved
Downing placard needs to be updated with all life jacket downing instructions
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 14 July 2016
Resolution: Donning placard for life jackets posted.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.