MAURY USCG vessel records Sign in
← All vessels

ZATARA

ZATARA is a 2003 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2009, most recently in July 2026, along with 92 deficiencies and 1 operational control.

Records from 2009 to 2026. Most recent: inspection, 22 July 2026.

Built
2003
Last inspected
22 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK7237
658120
Flag
UNITED STATES
368082470
Maury page id
psix-658120

Inspections, by type

…with no type recorded2
Years with a record 17 calendar years (2009–2026)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.5 ft × 23.0 ft × 8.4 ft
Registered tonnagegross 28 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAINE CAT · BREMEN, ME, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 8 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
22 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7237MMSI 368082470 · active · compulsorily equipped · granted 20 March 2019, expires 20 March 2029
WDE7576MMSI 367394950 · expired · compulsorily equipped · granted 12 February 2009, cancelled 20 April 2019 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 38

22 July 2026 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8434667
10 September 2025 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8229508
10 August 2025 Type not recorded
No type recorded · Station San Juan · USCG Southeast District (CGD-SE) · Activity 8206621
31 July 2025 Deadweight Survey · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8196768
28 January 2025 Damage Survey · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8071373
7 May 2024 COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7895257
12 September 2023 Deficiency Check · Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7734796
1 August 2023 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7734746
18 May 2023 Damage Survey · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7691764
3 March 2023 In-Service Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7647118
1 August 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7518490
28 January 2022 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7378026
3 August 2021 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7275843
16 October 2020 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7078270
28 July 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7018407
22 June 2020 Drydock Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6983980
20 August 2019 Deficiency Check · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6790163
15 May 2019 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6684986
7 May 2019 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6678543
17 September 2018 Drydock Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6540368
8 August 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6504902
12 October 2017 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6289011
1 August 2017 Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6227191
12 September 2016 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5996288
10 August 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5967623
6 August 2015 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5207358
15 May 2014 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4858574
25 May 2012 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4329456
18 May 2012 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4314107
28 February 2012 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4252362
1 February 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4235956
14 September 2011 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4144091
29 November 2010 Deficiency Check · In-Service Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3900084
15 March 2010 Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3696555
31 January 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3673942
11 May 2009 Deadweight Survey · Deficiency Check · COI Inspection · Plan Review "T" Boat · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3472449
28 April 2009 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3467079
26 January 2009 Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3400484

Deficiency record · 92

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 July 2025 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Vessel's port life float had cracks and was in poor condition. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2025
Resolved 8 September 2025
Resolution: Corrected with repair kit.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 January 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. A pinhole was found in the starboard side aft steering rook due to delamination of the FRP. Conduct repairs of FRP in kind, and contact USCG Marine Inspector to oversight the repairs; including when the vessel returns to the water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2025
Resolved 30 January 2025
Resolution: FRP repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 May 2024 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station. A light to indicate discharge and an audible alarm that sounds upon discharge. Vessel did not have a working indicating light and an no working indicating light. 46 CFR 181.420(b)(1)&(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 21 May 2024
Resolution: Conducted deficiency check with vessel representative new indicating ligth panels installed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 May 2024 Resolved
Separation of machinery and fuel tank spaces from accommodation spaces. Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. 46 CFR 177.405(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 8 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 May 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Instructions were not posted at the operating station. 46 CFR 185.510(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 21 May 2024
Resolution: Conducted deficiency check with vessel representative instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. There were 04 life jackets deteriorated and wasted. Passenger count reduced from 22 adults to 18 adults. 46 CFR 180.71(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 8 May 2024
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 May 2024 Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR part 80. The battery on the amp meter needs to be replaced and the VHF radio speaker was not working properly. 46 CFR 184.502 47 CFR part 80
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 21 May 2024
Resolution: Conducted deficiency check with vessel representative new VHF radio installed in kind.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions and minimize accidental personnel contact with energized parts; and prevent electrical ignition of flammable vapors. There were unidentified power cables loose and unattended that were not. 46 CFR 183.200 (c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 21 May 2024
Resolution: Conducted deficiency check with vessel representative and cables removed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 May 2024 Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. These stops may be structural or internal to the main steering gear. STBD side rudder post aluminum and had a bend. Port side was made fiberglass which was broken. 46 CFR 182.610 (e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 21 May 2024
Resolution: Conducted deficiency check with vessel representative corrected post to be the same material.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 1 August 2023 Resolved
11122 - Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The vessel's EPIRB battery is not operational. Vessel is restricted to operating within 3 NM from coast line. Replace EPIRB. 46 CFR 180.64 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 November 2023
Resolution: New EPIRB purchased and registered. Beacon ID 2DDAA F85E1 3FDFF
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2023 Resolved
11117 - Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring life buoy's grab line were of white nylon rope. Reaplace grab line with approved line. 46 CFR 180.70 (b) 10 C
Action required: 10 - Deficiency Rectified
Resolved 1 August 2023
Resolution: Crew replaced grab line with approved black polypropylene line.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 August 2022 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be serviceable condition must be repaired or replaced. Lifeline on ring life buoy was deteriorated by UV light and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 5 August 2022
Resolution: Lifeline replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 August 2022 Resolved
Each ring life buoy must be marked with Type II retro-reflective material. Retro-reflective material on ring life buoy was deteriorated and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 5 August 2022
Resolution: Retro-relective material replaced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 August 2021 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessel's shutoff valve on port side is not clearly labeled. In addition, remove old fuel shutoff pull point and labeling for the removed generator installation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 17 August 2021
Resolution: Fuel shutoff was labeled properly and old fuel shutoff installation was removed. Pictures were sent to confirm.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 August 2021 Resolved
Containers must be of a bright color and be clearly marked in legible contrasting letters at least 0.5 inches high with "DISTRESS SIGNALS". Container was not marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 17 August 2021
Resolution: Container was marked with proper labeling, pictures were sent to confirm.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 August 2021 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Name of vessel was not marked on either of the 04 paddles.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 17 August 2021
Resolution: Paddles were labeled with vessel name, pictures were received confirming.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 August 2021 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Non permanent type wing nuts were found on battery connections. Replace with proper connectors.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 17 August 2021
Resolution: Connections were replaced, pictures sent to confirm.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 July 2020 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Demonstrate proper operation of port-side midship high water visual and audible alarm.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2020
Resolution: All four bilge audio and visual alarms were found in good operating order.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2020 Resolved
Boundaries that separate machinery spaces from accommodation spaces must be lined with noncombustible panels or insulation approved in accordance with 46 CFR 164.009. Install removed and missing noncombustible panels in the engine room.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2020
Resolution: An approved fire insulation material was installed in both port & stbdside engine rooms, from the top of the deck to each sides of the engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2020 Resolved
The owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of machinery operation of the main propulsion machinery both ahead and astern. Demonstrate proper operation of both port and starboard main diesel engines during sea trials.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2020
Resolution: Both main diesel engines were found operational.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 28 July 2020 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necesitate abandoning the ship or the recovery of persons who have fallen overboard. Conduct a man overboard and abandon ship drills for the satisfaction of an USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2020
Resolution: Due to heavy sea conditions due to a tropical wave passing theough the island and based of the safe operational history of the vessel owner, it was decided due to safety to stay in port and discuss the drills.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 July 2020 Resolved
A vessel on a Limited Coastwise route must carry six hand orange smoke distress signals approved in accordance with 46 CFR 160.021 in subchapter Q. Vessel must be equipped with six hand orange smoke distress signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2020
Resolution: Distress signals were purchased and placed on board.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 28 July 2020 Resolved
The VHF-DSC radio should be properly connected to a GPS Receiver or have a VHF-DSC marine radio with integral GPS. Demonstrate that current radio is connected to a GPS receiver or install a VHF-DSC radio with integral GPS and have the MMSI number entered in the radio. 47CFR80.905
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 16 September 2020
Resolution: Vessel owner replaced existing VHF radio with a new VHF GPS ready integral radio.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 July 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date U.S. Coast Pilot and COLREGS. Provide an updated U.S. Coast Pilot and Navigation Rules (COLREGS).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 5 August 2020
Resolution: Publications were placed on board, they were stowed in the office during the dry dock process.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 28 July 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 17 September 2020
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 May 2019 Resolved
On 14May2019 received the report from the operations manager of East Island Excursions, that port side rudder hit the ground in shallow water and came free from the rudder shaft. The rudder was retrived and brougth to the shop in Puerto del Rey to effect repairs. Stbd rudder has a minor damage (the chipped off tip of the bottom corner) Upon the inspections of the port rudder shaft on the ZATARA, the shaft was found in a good condition. The rudder was in the repair shop with the plan to split it open, clean and bond it back to the shaft. Significant pitting on both propellers was also found.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2019
Resolved 16 May 2019
Resolution: On 17May Captain Master of East Island Excursions sent email, stating: "Today at 4:45 we made the splash of the boat Zatara. We did a Sea Trial to verify the maneuverability of the boat and confirm that it can turn on both sides with its rudder."
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 7 May 2019 Resolved
Each opening in a deck or a bulkhead that is exposed to weather must be fitted with a weathertight or a watertight closure device. None of the four hatches on the port side and starboard side are weather tight. The hatches are either missing clips or being help down with elastic bungee cords.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 27 June 2019
Resolution: Recieved photgraphic evidence of new handles in place and not damaged or missing.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 7 May 2019 Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. The last step leading into passenger area on the starboard side needs to be secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 19 July 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 7 May 2019 Resolved
An emergency instruction placard must containing the information pertaining to the specific vessel if an emergency were to occur. Update Emergency List to say “installed fire system” and remove the word “louvers”
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 9 May 2019
Resolution: Updated emergency list to proper verbage.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2018 Resolved
Make through-hull fittings available for inspection.
Action required: 705 - Other - as specified
Resolved 28 September 2018
Resolution: Vessel owner sent in invoice of replaced valves.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 August 2018 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery space, bilge. The visual and audible alarm does not work, but the bilge pumps are operational. Crew will regularly check bilge pump spaces.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 August 2018
Resolved 2 October 2018
Resolution: vessel fixed the wiring for the bilge and high water level alarm
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 October 2017 Resolved
Secure batteries in engine compartment
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 18 October 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 12 October 2017 Resolved
Prove proper operation of visual and audible alarms at the operating station of bilge alarm
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 October 2017 Resolved
Label PFD storage for child and adult
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 18 October 2017
Lifesaving › Lifefloat › Paddle
Issued 12 October 2017 Resolved
Properly equip life float and attach to the boat.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2017
Construction/Loadline › Structures › Manhole
Issued 12 October 2017 Resolved
Re-attach hatch cover hinge on the stbd side hatch
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 18 October 2017
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 12 October 2017 Resolved
Label bilge alarm at operating station for easier identification
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 19 October 2017
Engineering › Steering Gear System › Rudder
Issued 12 October 2017 Resolved
Tighten main base rudder post
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 18 October 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 August 2017 Resolved
Provide proof of servicing for all fire extinguishers.
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 12 October 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 August 2017 Resolved
Properly secure batteries in engine compartments
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 18 August 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 August 2017 Resolved
Replace fire extinguisher brackets in Port and STBD compartments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 12 October 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 August 2017 Resolved
Replace 110V cover plate in galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 12 October 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 August 2017 Resolved
Prove proper operation of stern light and mount properly.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 18 August 2017
Electrical › Electric Supply System (service) › Cable
Issued 12 September 2016 Resolved
Porperly secure dead-end wires found on starboard side engine compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 September 2016
Resolution: Dead ended wires have been removed from the space
Sail Rigging › Mast Step › Base
Issued 12 September 2016 Resolved
Submit repair proposal prior to effecting repairs to pitted areas found by mast step.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 September 2016
Resolution: satisfactory repairs were completed to the mast
Construction/Loadline › Penetrations › Valve Flange
Issued 12 September 2016 Resolved
Replace pitted thru-hull ball valve.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 September 2016
Resolution: pitted ball valve was replaced
Construction/Loadline › Penetrations › Valve Flange
Issued 12 September 2016 Resolved
Replace plastic thru-hull fitting connections.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 September 2016
Resolution: The plastic thru-hull fitting was replaced with a metalic connection.
Stability › Watertight Integrity › General
Issued 12 September 2016 Resolved
Make watertight thru-bolt located between the weather deck and the fuel tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 September 2016
Resolution: caulking was added around thru-bolt located between the weather deck and the fuel tank space to make them water tight.
Construction/Loadline › Hull › Stringer
Issued 12 September 2016 Resolved
Repair grinded area aft of head space bulkhead in the port side hull.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 September 2016
Resolution: grinded area aft of head space bulkhead in the port side hull was repaired.
Communications › Audible Communications › Horn/Whistle
Issued 10 August 2016 Resolved
Provide an approved sound producing device.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 11 August 2016
Resolution: Provided.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 August 2016 Resolved
VHF radio must be upgraded to a VHF-DSC class A radio IAW 47 CFR 80 for Sea Area A1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 18 August 2016
Resolution: VHF Radio was upgraded to a VHF-DSC class A radio IAW 47 CFR 80 for Sea Area A1
Communications › Radio Communications › EPIRB
Issued 10 August 2016 Resolved
Update NOAA EPIRB registration to include the MMSI number .
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 August 2016
Resolved 11 August 2016
Resolution: Provided.
Stability › Watertight Integrity › General
Issued 15 May 2014 Resolved
Make forward bulkheads watertight in way of cable runs in both engine rooms.
Action required: 705 - Other - as specified
Due 22 May 2014
Resolved 21 May 2014
Communications › Audible Communications › Bell
Issued 15 May 2014 Resolved
Properly provide bell with a mouth diameter of not less than 200 mm.
Due 29 May 2014
Resolved 28 May 2014
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 15 May 2014 Resolved
Properly provide rigging inventory/maintenance program.
Due 5 June 2014
Resolved 5 June 2014
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 15 May 2014 Resolved
Provide operable water temperature and oil pressure gauges for port and starboard engines at operating station.
Due 29 May 2014
Resolved 29 May 2014
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 15 May 2014 Resolved
Properly make changes to have only one pre-engineered fixed gas fire extinguishing system protecting each engine space.
Due 28 May 2014
Resolved 28 May 2014
Fire Fighting › Ventilation Systems › Operating Controls
Issued 15 May 2014 Resolved
Prove proper ventilation of shutdown upon pre-engineered fixed gas fire extinguishing system activation.
Due 28 May 2014
Resolved 28 May 2014
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 15 May 2014 Resolved
Prove proper operation of both port and starboard pre-engineered fixed gas fire extinguishing system alarms.
Due 29 May 2014
Resolved 29 May 2014
Stability › Watertight Integrity › General
Issued 15 May 2014 Resolved
Properly replace all unapproved nonmetallic through-hull valves/fittings with Forespar Marelon 932266 IAW original drawings.
Due 31 May 2015
Resolved 3 February 2015
Resolution: Vessel replaced bilge through hull valves with bronze ones.
Navigation › Piloting/Steering › Marine Charts
Issued 18 May 2012 Resolved
Provide updated nautical chart & notice to mariners.
Action required: 705 - Other - as specified
Due 25 May 2012
Resolved 25 May 2012
Fire Fighting › Fire Hydrants › Location/Position
Issued 18 May 2012 Resolved
Prove proper labeling of location for all fire extingushers.
Action required: 705 - Other - as specified
Due 25 May 2012
Resolved 25 May 2012
Communications › Radio Communications › EPIRB
Issued 18 May 2012 Resolved
Prove up to date EPIRB registration with vessel's call sign.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2012
Engineering › Fuel Oil Service System › Tank
Issued 18 May 2012 Resolved
Provide access to fuel oil tank.
Action required: 705 - Other - as specified
Due 25 May 2012
Resolved 25 May 2012
Lifesaving › Lifefloat › Serviceable
Issued 18 May 2012 Resolved
Repair or replace life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2012
Lifesaving › Lifebuoys › Serviceable
Issued 18 May 2012 Resolved
Replace retro-reflective material on liferings with SOLAS approved type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Engineering › Fuel Oil Service System › Filter
Issued 18 May 2012 Resolved
Provide flame guard for generating fuel oil filter,
Action required: 705 - Other - as specified
Due 25 May 2012
Resolved 18 May 2012
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 February 2012 Resolved
Provide proof of valid Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Resolution: COD was presented during the inspection.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 28 February 2012 Resolved
Prove pre-employment drug testing for crew members.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Resolution: Vessel owner/Rep presented evidence.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 February 2012 Resolved
Prove proper alcohol testing device on board vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Resolution: Alcohol test device was on board.
Lifesaving › Lifefloat › Retroreflective Material
Issued 28 February 2012 Resolved
Properly afix retro-reflective material on life buoys.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2012
Lifesaving › Hand Flares › Quantity
Issued 28 February 2012 Resolved
Prove proper amount of visual distress signals (flares).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Resolution: Vessel owner/rep have the correct amount.
Lifesaving › Lifefloat › Markings
Issued 28 February 2012 Resolved
Prove proper markings on life floats and paddles.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Resolution: Paddels and lifefloat were marked.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 February 2012 Resolved
Prove proper operations of all water lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Resolution: All waterlight were in operation.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 February 2012 Resolved
Prove proper operations of navigation lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Resolution: Navligths were in operation.
Navigation › Piloting/Steering › Marine Charts
Issued 14 September 2011 Resolved
Charts onboard are from 2005. Require up to date charts for area of operation.
Condition: Invalid
Due 28 September 2011
Resolved 20 September 2011
Resolution: Received confimation of puchase of updated charts.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 September 2011 Resolved
Expired eye flush/dressing packs, and expired iodine applicators. Incomplete first aid kit IAW 46 CFR Table 160.041
Condition: Improper/Lack of Maintenance
Due 21 September 2011
Resolved 20 September 2011
Resolution: Reciepts provided.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 14 September 2011 Resolved
Need to provide rigging inspection maintenance worksheet IAW Inspection Note #13.
Action required: 705 - Other - as specified
Due 14 October 2011
Resolved 20 September 2011
Resolution: Logs provided to Coast Guard.
Navigation › Piloting/Steering › Marine Charts
Issued 29 November 2010 Resolved
Provide up to date charts for the current area.
Due 6 December 2010
Resolved 9 December 2010
Lifesaving › Lifefloat › Painter
Issued 29 November 2010 Resolved
Install painter with properly sixed weak link on both lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2010
Lifesaving › Lifebuoys › Approval
Issued 29 November 2010 Resolved
Attach approved retroflective tape to both sides of each lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2010
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 29 November 2010 Resolved
Provide proof of current contract with an approved drug consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2010
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 March 2010 Resolved
Retroreflective tape was worn on lifebuoys. Crew must replace the tape in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 15 March 2010 Resolved
Complete servicing on 02 fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2010
Resolved 16 March 2010
Construction/Loadline › Structures › Superstructure
Issued 15 March 2010 Resolved
Requires initial rigging survey. Sailboat was built in 2003 and has not undergone initial survey.
Condition: Improper/Lack of Maintenance
Due 15 April 2010
Resolved 8 April 2010
Communications › Radio Communications › VHF Radiotelephone
Issued 11 May 2009 Resolved
PROVIDE A COPY OF FCC MARINE OPERATORS PERMIT.
Due 15 June 2009
Resolved 1 June 2009
Documentation › Certificates/Documents › Stability Letter
Issued 11 May 2009 Resolved
PROVIDE A COPY OF STABILITY LETTER FROM MSC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2009
Lifesaving › Hand Flares › Quantity
Issued 11 May 2009 Resolved
PROVIDE THE REQUIRED NUMBER OF SIGNALING DEVICES.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2009
Communications › Audible Communications › Horn/Whistle
Issued 11 May 2009 Resolved
INSTALL SMOKE DETECTOR (UL 217 APPROVED) IN INSPECTION TUNNEL BETWEEN ENGINE ROOMS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2009
Engineering › Fuel Oil Service System › Filter
Issued 11 May 2009 Resolved
Install approved fuel filters as per 46 CFR 182.455 (6) in the fuel supply lines to both main propulsion engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2009
Construction/Loadline › Hull › Bottom Plating
Issued 11 May 2009 Resolved
Provide proof of lay-up for the VELA VIA ON. 1149053. There are two options to satisfy this requirement: a) Provide notarized statement from owner of a sister vessel stating time & area the vessel was operated and any hull repairs in the past 5 years. Also provide a notarized statement from the builder stating the lay-up was the same as the KATHELEEN D. b) A plug may be removed from the hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2009
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 11 May 2009 Resolved
INSTALL NON-COMBUSTIBLE PANELS OR INSULATION APPROVED IAW 46CFR164.009 IN THE MACHINERY SPACE BOUNDRIES THAT SEPERATE THOSE SPACES FROM ACCOMADATION SPACES.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2009

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.