Documentation record
Registered dimensions (L × B × D)64.8 ft × 23.6 ft × 5.5 ft
Registered tonnagegross 39 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALL AMERICAN MARINE INC · BELLINGHAM, WA, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portLAHAINA, HI
Endorsements, as the file codes themcw_un, fi, reg
DocumentationValid · issued 28 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Simplified, Gross Ton
31 - Simplified, Net Ton
68342 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 25 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 25
29 January 2026
Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8303540
21 January 2025
Damage Survey · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8067229
11 December 2024
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8045981
12 September 2024
In-Service Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8001758
1 August 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7961797
6 December 2023
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7833560
9 November 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7591787
9 September 2022
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7554755
22 August 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7538387
15 February 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7396391
23 November 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7356527
22 November 2021
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7362192
30 March 2021
In-Service Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7165902
29 October 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7086528
10 September 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7055595
13 August 2020
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7032449
6 March 2020
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6922016
26 November 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6864114
19 November 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6583869
9 November 2018
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6578200
6 September 2018
Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6515415
11 January 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6336688
13 September 2017
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6266139
1 December 2016
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306034
15 August 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5969900
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 January 2026
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temp, and lube oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Digital display at operating station for port engine not working. Make display operational to include RPM, Temp., and oil pressure. 46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2026
Resolved 4 February 2026
Resolution: Swapped out faulty relay. Display working as intended.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2024
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Light cover in port engine room missing. 46 CFR 183.410(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2025
Resolved 8 January 2025
Resolution: New light cover installed. All sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 December 2024
Resolved
On a vessel of more than 65 feet in length carrying more than 49 passengers, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure on not less than 60 PSI at the pump outlet. The fire pump outlet pressure gauge providing inaccurate readings, requires replacement. Gauge replaced, pump tested and providing adequate pressure (60psi) to fire main. No further requirements. No further requirements.
46 CFR 181.300(b)
Action required: 10 - Deficiency Rectified
Resolved 11 December 2024
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 August 2024
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Corrosion identified on port hull transom. Submit repair proposal to the attending MI.
46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 27 August 2024
Resolution: Completed 18"x52" insert. Vac-box and dye penetrant used as NDT. Repairs found satisfactory
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 August 2024
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Two cracks identified on vessel. One located on the port shaft strut, and one located in the port side hold amidships. Submit repair proposal to the attending MI.
46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 5 August 2024
Resolution: Grinded out cracks with relief cuts and drill stops. Re-welded. Used dye pen NDT to verify good weldment.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 August 2024
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Localized pit identified in the port side hold next to AC raw water intake valve. Submit repair proposal to the attending MI.
46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 5 August 2024
Resolution: Grinded out and conduted base metal repair on localized pit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 December 2023
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Aluminum steering connector rod tab from ram to cross connect is corroding and pitting where dissimilar metals meet. Replace corroded material to good aluminum or provide alternate system that operates as intended.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2024
Resolved 11 December 2023
Resolution: New connecting rod bolted in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 November 2021
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and is operation for the purpose intended. Windlass is not operational. Provide operational windlass.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 15 December 2021
Resolution: Windlass installed and operational.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 November 2021
Resolved
A pre-engineered fixed gas fire fighting extinguishing system must be installed in accordance with the manufactures instructions. Fireboy port side requires reset by pressing stop button to engage override while starboard side override operates without pressing stop button. Make both systems operate identically for use in emergent situations and ensure they are installed IAW manufacturer.
46 CFR 181.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2021
Resolved 15 December 2021
Resolution: Both fire systems installed the same and IAW manufacturer.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 October 2020
Resolved
Port side fire pump does not have operational gauge at fire pump. The pump outlet must be fitted with a pressure gauge. Provide operational pressure gauge at pump outlet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2020
Resolved 10 November 2020
Resolution: Gauge provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2020
Resolved
Port side MTU engine control box supported by bungee cords. Bracket/bolts broken. Properly secure/mount MTU engine control box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2020
Resolved 10 November 2020
Resolution: Engine control box mounted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 September 2020
Resolved
A pre-engineered fixed gas fire extinguishing system must (Be capable of manual actuation from outside the space in addition to automatic shutdown by a heat detector. Port engine room fireboy had glass ampule cracked and liquid drained out rendering incapable of automatic activation.
46 CFR 181.420(a)(2)
46 CFR 181.420(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2020
Resolved 10 September 2020
Resolution: New fire boy installed and tested.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 9 November 2018
Resolved
Public address system was inoperative. Repair in accordance with 46 CFR 184.610.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 November 2018
Resolution: Public address system repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2018
Resolved
Conduct post dry dock sea trial to satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 6 October 2018
Resolved 17 October 2018
Resolution: [name withheld], and caterpillar tech conducted sea trial to verify maintenance conducted during dry dock meets warranty.
Construction/Loadline › Hull › Weld
Issued 13 September 2017
Resolved
Affect proper repairs to the weld along the interior starboard side plating locating in the collision bulkhead of the port hull to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2017
Resolved 19 September 2017
Resolution: Cracked weld seam renewed following an approved weld procedure. Tested satisfactroy.
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 August 2016
Resolved
Replace cracked longitudinals in portside void forward of collision bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2016
Construction/Loadline › Hull › Hull Plating
Issued 15 August 2016
Resolved
Provide plan proposal for insert repair on port side lazarette bottom plate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2016