MAURY USCG vessel records Sign in
← All vessels

FRANCES

FRANCES is a 2003 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2005, most recently in May 2025, along with 25 deficiencies, 1 operational control and 1 casualty investigation in 2007.

Records from 2005 to 2025. Most recent: inspection, 28 May 2025.

Built
2003
Last inspected
28 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC6238
658939
Flag
UNITED STATES
367053360
Maury page id
psix-658939

Inspections, by type

…with no type recorded1
Years with a record 15 calendar years (2005–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 18.0 ft × 5.0 ft
Registered tonnagegross 37 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHASKET HILDRETH · PORTLAND, ME, UNITED STATES · built 2003
Hull materialSteel
PropulsionSail
Hull shapeBox
Hull configurationMonohull
Hailing portPORTLAND, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC6238MMSI 367053360 · active · compulsorily equipped · granted 12 April 2025, expires 29 June 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 23

28 May 2025 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8146106
3 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8104534
8 August 2024 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7981013
25 August 2023 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7786175
18 May 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7694041
25 August 2022 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7543541
24 June 2022 DAPI Audit
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7486228
29 April 2021 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7185822
22 May 2020 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6957738
18 July 2019 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6755182
16 August 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6525553
18 August 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6244653
23 May 2017 Administrative Inspection · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6143131
5 July 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5922725
27 June 2012 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4356346
9 January 2012 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4221766
9 July 2008 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3260247
27 July 2007 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3020728
25 July 2007 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3007309
18 April 2007 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2910165
5 June 2006 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2671261
23 February 2006 Construction Oversight
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2590691
13 June 2005 Hull Examination · Initial Certification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2383496

Deficiency record · 25

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 June 2025 Resolved
Provide a preventive maintenance plan for your sail rigging log. Should include specific intervals for regular maintenance and inspections.
Due 19 June 2025
Resolved 12 June 2025
Resolution: Preventive maintenance plan provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2025 Resolved
Provide a non-corrosive clip for your ring buoy light where it wraps around the body of the ring buoy.
Due 19 June 2025
Resolved 12 June 2025
Resolution: Clip provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 June 2025 Resolved
Properly mount your port and starboard sidelights on vessel. Lights are currently tied to shrouds.
Due 19 June 2025
Resolved 12 June 2025
Resolution: Lights mounted on side boards.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 August 2022 Resolved
Complete DSC test on VHF radio to receive an acknowledgement from USCG.
Action required: 705 - Other - as specified
Due 25 August 2022
Resolved 25 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 August 2022 Resolved
Replace fuel seperator in yawl boat with an approved filter.
Action required: 705 - Other - as specified
Due 25 October 2023
Resolved 25 August 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 August 2022 Resolved
Provide ballast map during dry dock.
Action required: 705 - Other - as specified
Due 25 October 2023
Resolved 25 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2021 Resolved
STBD nav light and stern light INOP.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 6 July 2022
Resolution: Lights fixed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 April 2021 Resolved
Vessel missing up-to-date navigational charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 6 July 2022
Resolution: Charts provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2021 Resolved
Vessel does not have suitable strainers installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 6 July 2022
Resolution: Duplicate def.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 1 August 2019 Resolved
Vessel has holes in watertight bulkheads. Fill holes and make watertight.
Due 1 October 2019
Resolved 6 July 2022
Resolution: Holes filled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2019 Resolved
Bilge piping does not have proper strainers. Install strainers.
Action required: 10 - Deficiency Rectified
Due 1 October 2019
Resolved 20 August 2024
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 5 July 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 5 July 2016
Resolved 1 August 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 5 July 2016 Resolved
Provide current FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 5 September 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 5 July 2016 Resolved
Provide GPS input to DSC VHF-FM radio and program MMSI into DSC VHF-FM radio.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 1 August 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 July 2016 Resolved
Stow batteries inside of a battery box and secure battery box from movement.
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 1 August 2016
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 9 July 2008 Resolved
Provide current drug testing roster.
Action required: 705 - Other - as specified
Due 23 July 2008
Resolved 28 August 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 July 2008 Resolved
Provide segregation between child and adult PFDs.
Action required: 705 - Other - as specified
Due 23 July 2008
Resolved 1 August 2008
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 9 July 2008 Resolved
Properly rig IBA weak link, painter line, tie down strap and hydrostatic release unit. Corrected on the spot.
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 9 July 2008
Resolution: Corrected on the spot.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 July 2008 Resolved
Secure overboard discharge valve for type III MSD while within three miles from shore as discussed with the CG Marine Inspector. Corrected on the spot.
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 9 July 2008
Resolution: Corrected on the spot.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 24 July 2007 Resolved
Provide means to secure overboard discharge valve on MSD and post polution placard.
Action required: 705 - Other - as specified
Due 24 August 2007
Resolved 31 July 2007
Resolution: Received call from vessel representative [name withheld] that MSD overboard discharge valve is locked and polution placard is posted.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 July 2007 Resolved
Prove enrollment in Drug and Alcohol consortium.
Action required: 705 - Other - as specified
Due 24 August 2007
Resolved 24 July 2007
Resolution: Operator [name withheld] faxed current enrollment to inspections office.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 24 July 2007 Resolved
Properly rig the hydrostatic release on the Inflatable Buoyant Apparatus.
Action required: 705 - Other - as specified
Due 24 August 2007
Resolved 24 July 2007
Resolution: Discussed with the crew proper rigging of the IBA. IBA was secured to the vessel improperly bypassing the hammar hydrostatic release. Crew properly rigged IBA sea painter and IBA securing strap with hydrostatic release on the spot.
Construction/Loadline › Hull › Weld
Issued 18 April 2007 Resolved
Repair welds as pointed out by CG Marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 11 May 2007
Resolution: Several welds had pinholes and excessive porisity. O/O had welds ground out and rewelded.
Construction/Loadline › Penetrations › Valve Flange
Issued 18 April 2007 Resolved
Replace MSD throughhull valve. Valve wasted and does not fully close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 11 May 2007
Lifesaving › Lifefloat › Float-free Link
Issued 5 June 2006 Resolved
Vessel has two 15 person lifefloats not attached to the vessel and no weak link.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 5 June 2006
Resolution: Assisted vessel owner with proper installation of life float storage. Owner purchased proper weak link and attached to vessel. Sea painter with lifefloats now rigged properly for float free arrangement.

Casualty record · 1

27 July 2007Routine · role: Involved in a Marine Casualty · activity 3020728
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.