Records from 2016 to 2025. Most recent: inspection, 19 August 2025.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.0 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS, INC. · TARPON SPRINGS, FL, UNITED STATES · built 1988
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationTwin Hull
Hailing portRIVIERA BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
19 August 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8207154
14 November 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8034897
27 August 2024
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7991118
31 May 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7701658
15 November 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7594825
16 August 2022
Administrative Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7534964
15 November 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7350954
19 August 2020
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7037287
4 August 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7024078
22 November 2019
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6860543
30 November 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6589853
4 October 2018
Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6554578
21 August 2018
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6518751
5 December 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6318264
27 October 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6030811
30 August 2016
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5993128
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 August 2025
Resolved
A submersible electric bilge pump may be used provided that: A positive shutoff valve is installed at the hull penetration. Valves have a piece of hose between hull and valve.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2025
Resolved
Gauges to indicate cooling water discharge temperature and lubricating oil pressure shall be provided for all
propulsion engines and located so as to be in view of the operator. Gauges do not show water temp or oil pressure.
Old "T" 46 CFR 182.15-5
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 August 2025
Resolved
A submersible electric bilge pump may be used provided that: the pump is permanently mounted. Aft STBD pumps not mounted.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2025
Resolution: Mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 November 2022
Resolved
Life ring not properly mounted. Life ring to be mounted in a way that it can be rapidly cast loose. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 22 November 2022
Resolution: Life ring mounted SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 November 2022
Resolved
Life ring lifeline not of the proper type or length. Attach at least 60' of buoyant lifeline that is resistant to deterioration from ultraviolet light to the life ring.
46 CFR 180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 22 November 2022
Resolution: Lifeline proper type and length.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 November 2022
Resolved
Life ring floating waterlight lanyard is not of the proper length. Length must be at a minimum of 3' and maximum length of 6'. 46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 22 November 2022
Resolution: Lanyard proper length.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 November 2022
Resolved
Emergency instructions are not posted. Post vessel's emergency instructions at operating station. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 22 November 2022
Resolution: Emergency instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 December 2019
Resolved
Life ring grab line parted when pulled on. Replace grab line or replace life ring. 46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 December 2019
Resolution: Life ring replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 30 August 2018
Resolved
Make permanent repairs to holes in deck and rotted wood above port pontoon amidships and above stbd pontoon just forward of watertight hatch. Repairs to be made at next yard period.
46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 31 October 2018
Resolution: Repairs made to wasted deck areas.