MAURY USCG vessel records
← All vessels

SILVER LADY

SILVER LADY is a 2003 freight ship. The Coast Guard has recorded 11 inspections since 2017, most recently in October 2025, along with 3 deficiencies and 3 operational controls.

Records from 2017 to 2025. Most recent: inspection, 24 October 2025.

Built
2003
Last inspected
24 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9279367
9HA4060
659964
Flag
MALTA
Maury page id
psix-659964

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 4 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it50329 - Dead Weight, Metric Ton
58136 - Displacement, Metric Ton
27989 - Convention (Subpart B), Gross Ton
17077 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 11

24 October 2025 PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8251746
24 October 2025 Bulk Liquid Transfer Monitor
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8259180
9 September 2024 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7991843
6 September 2024 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7997696
9 October 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7327798
14 July 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7255698
7 July 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7248143
21 September 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6271804
7 April 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6119598
7 April 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6124063
13 March 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6098383

Deficiency record · 3

03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 24 October 2025 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The marks shall be plainly visible. PSCO observed the deckline painted in the same color as the surrounding hull.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2025
Resolved 4 November 2025
Resolution: PSC NOLA received a class report form RINA satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 September 2024 Resolved
Each survival craft shall be stowed fully equipped as required by this chapter and the Code. Watertight receptacles containing a total of 3L of fresh water for each person the lifeboat is permitted to accommodate. PSCO discovered that both port and starboard life boats have 50L of water in which they need 75L for each lifeboat. 74SOLAS (20) III/ 13.1.4 LSA Code 4.4.8.9
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2024
Resolution: Vessel purchased and provided both photographic evidence and receipts of approved water.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 9 September 2024 Resolved
The company should establish procedures, plans, and instructions, including checklists as appropriate for key shipboard operations concerning the protection of the environment. Vessel has no sewage holding tank and class has authorized sewage to be stored in the aft peak tank via statutory certificate. However, there are no shipboard instructions on how to transfer/ dispose of the sewage from the tank nor is the situation described in the ballast water management plan. ISM Code 18 Pt. A/ 7
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 October 2025
Resolution: PSCO Observed shipboard instructions on how to transfer/dispose of sewage from aft-peak ballast tank, received class approval for the use of the tank to store sewage, and aknowledgement for the use of the aft-peak ballast tank to stor sewage in the BWMP.

Ownership record