MAURY USCG vessel records
← All vessels

KAVO AETOS

KAVO AETOS is a 2003 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in September 2025, along with 7 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 18 September 2025.

Built
2003
Last inspected
18 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 September 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9290232
660765
Flag
MARSHALL ISLANDS
Maury page id
psix-660765

Documentation record

Tonnage as PSIX records it52384 - Dead Weight, Metric Ton
60772 - Displacement, Metric Ton
30054 - Convention (Subpart B), Gross Ton
18207 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

12 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

18 September 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8237077
23 April 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8117555
22 April 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8116740
28 April 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7440163
13 June 2020 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6975388
4 June 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6967831
3 June 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6967224
30 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6963980
30 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6964026
28 July 2017 Ballast Water Examination · ISPS II Exam · COE-Administrative · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6223923
13 February 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6086336
1 October 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6010736

Deficiency record · 7

Engineering › Fuel Oil Service System › Tank
Issued 13 February 2017 Resolved
1499-Other (Prop. & Aux. Machinery)-Every steam pipe and every fitting connected shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected; There is a pinhole leak in the steam coil of the number three fuel oil tank.-74 SOLAS (04)II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 March 2017
Resolved 13 June 2020
Engineering › Steam Boiler (propulsion) › Piping
Issued 13 February 2017 Resolved
1499-Other (Prop. & Aux. Machinery)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board; oil was discovered inside the cascade tank due to a leak inside the number three fuel oil tank. 74 SOLAS (04)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 March 2017
Resolved 13 June 2020
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 October 2016 Resolved
2550-Maintenance of shipping equipment-PSCO found a small square block of wood in the quick closing valve for the ME and GE fuel service tank. Attached to the block of wood was a small lanyard which was secured to the piping. 2nd A/E stated the block of wood was placed in the quick closing valve to prevent it from closing and causing a black out. SOLAS 74 (2014) XI-1/4 30a.
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 4 October 2016
Resolution: Class attended vessel. Conducted review of situation that lead to crew blocking fuel valves and conducted satisfactory test of valve operation.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 1 October 2016 Resolved
0610-Lifeboats-PSCO observed that the port side lifeboat steering system was not functioning as designed. During rotation of the steering wheel by the 3rd Officer the rudder was not turning with the steering wheel. SOLAS 74 (am) III/20.2 17a.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2016
Resolution: Hydraulic hose identified as leaking. Hose replaced and steering tested to the satisfaction of Class surveyor.
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 1 October 2016 Resolved
0650-Lifebuoys-PSCO observed both lifebuoys on the port and starboard bridge wings installed in a quick release arrangement and provided with self-activated smoke signal and self-igniting light were 3kg. SOLAS 74 (am) III/34 17a.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2016
Resolution: Bridge lifebouys replaces with appropriate 4kg lifebouys.
Operations/Management › Pollution › Control of Garbage
Issued 1 October 2016 Resolved
2120-Garbage-PSCO observed all plastic garbage storage locations full. Provide receipts for the discharge of garbage to a reception facility prior to departure. MARPOL V/9.1 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2016
Resolution: Garbage put to shore and receipts submitted to Coast Guard
Engineering › Steering Gear System › Power Unit
Issued 1 October 2016 Resolved
1499-Other (Prop. & Aux. Machinery)-PSCO observed that the level of the hydraulic oil storage tank was low and insufficient to recharge the power actuating system. Rectify by 8Oct16. SOLAS 74 (am) II-1/12.3 a.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 October 2016
Resolved 4 October 2016
Resolution: Steering gear hydraulic oil storage tank filled to capacity (350l) which is in excess of one steering pump requirement (208l)

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.