SOLARIS

SOLARIS is a 2004 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in February 2026, along with 48 deficiencies, 1 operational control and 2 casualty investigations between 2007 and 2008.

Records from 2007 to 2026. Most recent: inspection, 23 February 2026.

Built
2004
Last inspected
23 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

8990483
WDQ2041
661347
Flag
UNITED STATES
Maury page id
psix-661347

Inspections, by type

Years with a record 11 calendar years (2016–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)106.6 ft × 26.0 ft × 7.0 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)106.6 ft × 26.0 ft × 7.0 ft
ITC tonnagegross 355 / net 108
BuilderFREEPORT SHIPBUILDING HULL #267 INC · FREEPORT, FL, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT WALTON BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it355 - Convention (Subpart B), Gross Ton
74 - Regulatory (Subpart C or D), Gross Ton
108 - Convention (Subpart B), Net Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 21

23 February 2026 Deficiency Check · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8314686
9 February 2026 Annual Inspection · Deficiency Check · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8308644
5 March 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8088959
20 February 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8082221
7 November 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8031874
11 March 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872664
11 January 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7848494
15 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7651451
2 January 2023 Drydock Exam · Hull Examination · Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7624647
14 March 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7411558
9 February 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7138538
15 January 2021 Administrative Inspection · Deficiency Check · In-Service Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7125174
11 January 2021 Drydock Exam · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7122839
2 March 2020 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6918723
20 March 2019 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6641846
31 October 2018 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6571797
2 March 2018 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6364958
22 August 2017 Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6243797
27 December 2016 Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6062718
5 December 2016 Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6053041
8 March 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5828804

Deficiency record · 48

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 February 2026 Resolved
A fire pump must have the minimum capacity of 50gpm and not less than 60psi at the pump outlet. When the fire pump is supplying one fire hose it drops from 70psi to 25psi.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2026
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2026 Resolved
The vessel must be equipped with arrangement for draining any watertight compartment. There are numerous void spaces with bilge piping suction lines that was not capable of pumping water from the compartment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2026
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2026 Resolved
Fuel shut off valves must be provided to stop fuel flow. When operating the valve from outside the space, as well as at the valve, the valve rotates 360 degrees. It does not stop in the closed position.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2026
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 February 2026 Resolved
The following operational hazards must be corrected: 1. Both shaft seals are excessively leaking 2. The port sea strainer is excessively leaking 3. The bilge pump excessively leaks when in operation
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2026
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 February 2026 Resolved
The following operational hazards must be corrected: 1. The PA system cannot be heard from inside the main deck heads. 2. The ER needs the elighting to be permanently installed. 3. Install a guard on the port side fan motor pully. 4. Correct the exhaust leak in the lazarette. 5. Complete an overhaul of the sewage collection system to include drains, piping, retention devices, etc.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 23 February 2026
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 20 February 2025 Resolved
Vital system piping must be ferrous material and subject to vessels pressure of more than 150psi. The fire main relief line has two pinholes.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2025
Resolved 5 March 2025
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 January 2024 Resolved
46 CFR 177.100 - The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel was being pushed by ITV DELTA when they allided with a pier. The vessel sustained a 1/8" X 14" wide inset. Vessel needs to repair the inset at next scheduled drydock due 31JAN25.
Action required: 705 - Other - as specified
Due 31 January 2025
Resolved 20 February 2025
Resolution: Completed repairs during 2025 DD.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 January 2023 Resolved
The installation of the portable fire extinguishers must be to the satisfaction of the Officer in Charge, Marine Inspections. Several portable fire extinguishers were found to be mounted in an improper bracket. Provide evidence of extinguishers mounted in the required brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2023
Resolved 15 March 2023
Resolution: Owner procured several fire extinguisher brackets and had them installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 January 2023 Resolved
Each vessel must have permanent draft marks at each end of the vessel or have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. A loading mark must be a horizontal line of at least 8 inches in length and 1 inch in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2023
Resolved 30 January 2023
Resolution: Received photos of draft marks added.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 14 March 2022 Resolved
Inspect vessel interior in accordance with 46 CFR 176.802. Multiple forepeak gusset welds were deteriorated. Repair by conclusion of 2023 drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 January 2023
Resolution: Gusset welds repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 February 2021 Resolved
Reduce excessive use of power strips throughout vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2021
Resolution: Power strips removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2021 Resolved
All Air Conditioner motors need to be hard wired to controllers vice pig tails.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 March 2021
Resolution: Pumps hardwired to controllers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2021 Resolved
Properly secure air conditioner sea strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2021
Resolution: Strainer properly secured.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 February 2021 Resolved
Renew wasted metal or adjust engine room air dampners air tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 March 2021
Resolution: Wasted metal replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 February 2021 Resolved
Prove proper operation of fuel tank sight glass self closing valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2021
Resolution: Self closing valves were installed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 9 February 2021 Resolved
Provide proof of proper operation of vessel PA system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 March 2021
Resolution: PA system was repaired and operating properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2021 Resolved
Reduce excessive storage from voids throughout.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 March 2021
Resolution: Excess storage removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 February 2021 Resolved
Provide proof of valid radio safety certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2021
Resolution: Radio Cert provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 February 2021 Resolved
Provide proof of proper DSC radio programing
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 March 2021
Resolution: DSC programmed into radio.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2021 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Witnessed unauthorized repairs to hull plating while conducting a round at Blakely Boat Works. Vessel is not authorized to leave drydock or enter the water until all repairs to all safety contingent items are inspected and deem satisfactory to the OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2021
Resolution: Completed satisfactory hull plate renewals.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 March 2019 Resolved
PA system on main deck cannot be controlled from the pilot house. A vessel with more than one deck must have a public address system operable from the operation stations
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2019
Resolution: Vessel's audio tech found problem and satisfactory tested system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2019 Resolved
Port generator canot be operated with machinery guard in place due to the guard hitting the pulley system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2019
Resolution: Vessel's mechanic removed guard bent the support tabs and reinstalled. Test ran generator all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 March 2019 Resolved
STBD generator's water temp gauge inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2019
Resolved 11 April 2019
Resolution: Gauge was installed and verified to be operating.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 March 2019 Resolved
Engine room breaker panel had open blanks covered with electrical tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2019
Resolved 11 April 2019
Resolution: Proper blank covers were installed in place of electrical tape.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2019 Resolved
Generator panel power notification lights burnt out.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2019
Resolved 11 April 2019
Resolution: Bulbs were replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 March 2018 Resolved
Replace fire caulk on wire penitration between holds 2/3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 13 March 2018
Resolution: New fire caulk was installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 March 2018 Resolved
Provide 2 correct batteries for the liferingg lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 13 March 2018
Resolution: new approved batteries were installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 2 March 2018 Resolved
Provide bar fire extinquisher with a fixed mounting bracket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 13 March 2018
Resolution: corrected
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 March 2018 Resolved
Provide cover for electrial outlet on the stern near the coke machine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 13 March 2018
Resolution: a cover was installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 August 2017 Resolved
Provide 4 DOT approved alcohol test equipment.
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 14 September 2017
Resolution: Vessel provided alcohol test equipment
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 August 2017 Resolved
Provide burn gel in medical kit
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 14 September 2017
Resolution: Vessel provided burn gel
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 August 2017 Resolved
Properly label emergencvy exits
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 14 September 2017
Resolution: Vessel labeled emergency exits
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 August 2017 Resolved
Properly secure and store all gear in wedding hole and front hole compartments. Ensure spaces maintain adequate space for entry and emergency response.
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 14 September 2017
Resolution: Vessel properly stowed all gear
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 21 January 2017 Resolved
Ensure floor covering meets CG standards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 22 August 2017
Resolution: Vessel installed proper deck covering
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 March 2016 Resolved
Remove wing nuts from batteries in ENG room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 17 March 2016
Resolution: removed
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 8 March 2016 Resolved
install Blanks into Circuit Pannel board
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 17 March 2016
Resolution: installed
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 March 2016 Resolved
Remove portable lights in ENG room or make permenent
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 17 March 2016
Resolution: removed
Engineering › Fuel Oil Service System › Hose
Issued 8 March 2016 Resolved
Install chaffing gear on fuel hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 17 March 2016
Resolution: installed
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 8 March 2016 Resolved
re-Pack stern tube seals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 10 March 2016
Resolution: Repacked
Electrical › Lighting (service) › Lighting Fixture
Issued 8 March 2016 Resolved
Repair aft flood light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 17 March 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 8 March 2016 Resolved
Exhust fan above stove clean grease.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 10 March 2016
Resolution: cleaned
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 March 2016 Resolved
Remove freezer from under Galley, near vessel MSD
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2016
Resolved 10 March 2016
Resolution: removed.
Lifesaving › Lifebuoys › Serviceable
Issued 8 March 2016 Resolved
replace Life Ring Buoy on aft deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2016
Resolved 10 March 2016
Lifesaving › Lifebuoys › Approval
Issued 8 March 2016 Resolved
Life ring Buoy needs Refetive tape.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2016
Resolved 10 March 2016
Stability › Watertight Integrity › General
Issued 8 March 2016 Resolved
remove water from fwd and aft spaces on vessel. clean water tight hact gaskets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2016
Resolved 10 March 2016
Resolution: cleaned
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 March 2016 Resolved
provide first aid kit for vessel.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2016
Resolved 10 March 2016
Engineering › Fuel Oil Service System › Valve
Issued 8 March 2016 Resolved
lable fuel shut off valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 17 March 2016
Resolution: labled
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 March 2016 Resolved
Eng Room general house keeping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 17 March 2016

Casualty record · 2

26 May 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3105727
25 May 2008Routine · role: Involved in a Marine Casualty · activity 3218849
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.