SOLARIS is a 2004 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in February 2026, along with 48 deficiencies, 1 operational control and 2 casualty investigations between 2007 and 2008.
Records from 2007 to 2026. Most recent: inspection, 23 February 2026.
- Built
- 2004
- Last inspected
- 23 February 2026
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 48 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2007–2008
Identity
1149929
8990483
WDQ2041
661347
Flag
UNITED STATES
Maury page id
psix-661347
Inspections, by type
Years with a record
11 calendar years (2016–2026)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)106.6 ft × 26.0 ft × 7.0 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)106.6 ft × 26.0 ft × 7.0 ft
ITC tonnagegross 355 / net 108
BuilderFREEPORT SHIPBUILDING HULL #267 INC · FREEPORT, FL, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT WALTON BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it355 - Convention (Subpart B), Gross Ton
74 - Regulatory (Subpart C or D), Gross Ton
108 - Convention (Subpart B), Net Ton
50 - Regulatory (Subpart C or D), Net Ton
74 - Regulatory (Subpart C or D), Gross Ton
108 - Convention (Subpart B), Net Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 21
23 February 2026
Deficiency Check · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8314686
9 February 2026
Annual Inspection · Deficiency Check · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8308644
5 March 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8088959
20 February 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8082221
7 November 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8031874
11 March 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872664
11 January 2024
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7848494
15 March 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7651451
2 January 2023
Drydock Exam · Hull Examination · Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7624647
14 March 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7411558
9 February 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7138538
15 January 2021
Administrative Inspection · Deficiency Check · In-Service Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7125174
11 January 2021
Drydock Exam · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7122839
2 March 2020
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6918723
20 March 2019
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6641846
31 October 2018
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6571797
2 March 2018
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6364958
22 August 2017
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6243797
27 December 2016
Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6062718
5 December 2016
Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6053041
8 March 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5828804
Deficiency record · 48
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 February 2026
Resolved
A fire pump must have the minimum capacity of 50gpm and not less than 60psi at the pump outlet. When the fire pump is supplying one fire hose it drops from 70psi to 25psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2026
Resolved
The vessel must be equipped with arrangement for draining any watertight compartment. There are numerous void spaces with bilge piping suction lines that was not capable of pumping water from the compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2026
Resolved
Fuel shut off valves must be provided to stop fuel flow. When operating the valve from outside the space, as well as at the valve, the valve rotates 360 degrees. It does not stop in the closed position.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 February 2026
Resolved
The following operational hazards must be corrected:
1. Both shaft seals are excessively leaking
2. The port sea strainer is excessively leaking
3. The bilge pump excessively leaks when in operation
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 February 2026
Resolved
The following operational hazards must be corrected:
1. The PA system cannot be heard from inside the main deck heads.
2. The ER needs the elighting to be permanently installed.
3. Install a guard on the port side fan motor pully.
4. Correct the exhaust leak in the lazarette.
5. Complete an overhaul of the sewage collection system to include drains, piping, retention devices, etc.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 20 February 2025
Resolved
Vital system piping must be ferrous material and subject to vessels pressure of more than 150psi. The fire main relief line has two pinholes.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 January 2024
Resolved
46 CFR 177.100 - The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel was being pushed by ITV DELTA when they allided with a pier. The vessel sustained a 1/8" X 14" wide inset. Vessel needs to repair the inset at next scheduled drydock due 31JAN25.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 January 2023
Resolved
The installation of the portable fire extinguishers must be to the satisfaction of the Officer in Charge, Marine Inspections. Several portable fire extinguishers were found to be mounted in an improper bracket. Provide evidence of extinguishers mounted in the required brackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 January 2023
Resolved
Each vessel must have permanent draft marks at each end of the vessel or have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. A loading mark must be a horizontal line of at least 8 inches in length and 1 inch in height, with its upper edge passing through the
point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 14 March 2022
Resolved
Inspect vessel interior in accordance with 46 CFR 176.802. Multiple forepeak gusset welds were deteriorated. Repair by conclusion of 2023 drydock.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 February 2021
Resolved
Reduce excessive use of power strips throughout vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2021
Resolved
All Air Conditioner motors need to be hard wired to controllers vice pig tails.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2021
Resolved
Properly secure air conditioner sea strainer.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 February 2021
Resolved
Renew wasted metal or adjust engine room air dampners air tight.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 February 2021
Resolved
Prove proper operation of fuel tank sight glass self closing valves.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 9 February 2021
Resolved
Provide proof of proper operation of vessel PA system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 February 2021
Resolved
Reduce excessive storage from voids throughout.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 February 2021
Resolved
Provide proof of valid radio safety certificate.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 February 2021
Resolved
Provide proof of proper DSC radio programing
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Witnessed unauthorized repairs to hull plating while conducting a round at Blakely Boat Works. Vessel is not authorized to leave drydock or enter the water until all repairs to all safety contingent items are inspected and deem satisfactory to the OCMI.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 20 March 2019
Resolved
PA system on main deck cannot be controlled from the pilot house. A vessel with more than one deck must have a public address system operable from the operation stations
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2019
Resolved
Port generator canot be operated with machinery guard in place due to the guard hitting the pulley system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 March 2019
Resolved
STBD generator's water temp gauge inop.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 March 2019
Resolved
Engine room breaker panel had open blanks covered with electrical tape.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2019
Resolved
Generator panel power notification lights burnt out.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 March 2018
Resolved
Replace fire caulk on wire penitration between holds 2/3
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 March 2018
Resolved
Provide 2 correct batteries for the liferingg lights.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 2 March 2018
Resolved
Provide bar fire extinquisher with a fixed mounting bracket.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 March 2018
Resolved
Provide cover for electrial outlet on the stern near the coke machine.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 August 2017
Resolved
Provide 4 DOT approved alcohol test equipment.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 August 2017
Resolved
Provide burn gel in medical kit
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 August 2017
Resolved
Properly label emergencvy exits
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 August 2017
Resolved
Properly secure and store all gear in wedding hole and front hole compartments. Ensure spaces maintain adequate space for entry and emergency response.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 21 January 2017
Resolved
Ensure floor covering meets CG standards.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 March 2016
Resolved
Remove wing nuts from batteries in ENG room.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 8 March 2016
Resolved
install Blanks into Circuit Pannel board
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 March 2016
Resolved
Remove portable lights in ENG room or make permenent
Engineering › Fuel Oil Service System › Hose
Issued 8 March 2016
Resolved
Install chaffing gear on fuel hose.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 8 March 2016
Resolved
re-Pack stern tube seals.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 March 2016
Resolved
Repair aft flood light.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 March 2016
Resolved
Exhust fan above stove clean grease.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 8 March 2016
Resolved
Remove freezer from under Galley, near vessel MSD
Lifesaving › Lifebuoys › Serviceable
Issued 8 March 2016
Resolved
replace Life Ring Buoy on aft deck.
Lifesaving › Lifebuoys › Approval
Issued 8 March 2016
Resolved
Life ring Buoy needs Refetive tape.
Stability › Watertight Integrity › General
Issued 8 March 2016
Resolved
remove water from fwd and aft spaces on vessel. clean water tight hact gaskets.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 March 2016
Resolved
provide first aid kit for vessel.
Engineering › Fuel Oil Service System › Valve
Issued 8 March 2016
Resolved
lable fuel shut off valves
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 March 2016
Resolved
Eng Room general house keeping.
Casualty record · 2
26 May 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3105727
25 May 2008Routine · role: Involved in a Marine Casualty · activity 3218849
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.