Records from 2017 to 2022. Most recent: inspection, 1 April 2022.
Inspection history · 8
1 April 2022
COC-CVE Annual
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7411837
8 October 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7329143
18 February 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7155211
10 July 2019
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6744130
22 June 2019
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6725583
7 June 2019
COC-CVE Initial · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6686827
31 August 2018
COC-CVE Initial
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6528533
21 September 2017
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6323439
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 1 April 2022
No resolution recorded
"Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the Administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm..." Oily water separator, 15 ppm meter, had an expired calibration certificate with incorrect (MEPC.107(49)) standard tested and noted instead of Installed MEPC.60(33).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2022 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 April 2022
No resolution recorded
"The owner of a vessel to which this section applies shall...maintain on the vessel equipment and meterials for performing a medical examination in sexual assault cases to evaluate the patient for trauma, provide medical care, and preserve relevant medical evidence." Vessel has no available sexual assault kits on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 April 2022
No resolution recorded
"Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: The doors shall be self-closing." A46, A57, A63, A43, A17, A94, A45, A36, A34, A93, & A40 Fire Screen Doors would not close and latch after release.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2022 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 July 2019
Resolved
1430-ELECTICAL INSTALLATIONS SHOULD BE SUCH THAT ALL ELECTICAL AUX SERVICES NECESSARY FOR MAINTAINING THE SHIP IN NORMAL OPERATION AND HABITABLE CONDITIONS WILL BE ENSURED WITHOUT RECOURSE TO THE EMERGENCY SOURCE OF ELECTICAL POWER. A MAIN SOURCE OF ELECTRICAL POWER OF SUFFICIENT CAPACITY TO SUPPLY ALL THOSE SERVICES MENTIONED IN REG 40.1.1 SHALL BE PROVIDED. THIS MAIN SOURCE OF ELECTRICAL POWER SHALL CONSIST OF AT LEAST TWO GEN SETES. THIS SHIP HAS ONLY ONE MAIN GENERATOR OPERATIONAL AND INTENDS TO USE THE EMERGENCY GEN AND SHAFT GENERATOR AS ALTERNATE MEANS OF RESTORING POWER AND MAINTAINING NORMAL OPERATIONS IN THE EVENT OF A BLACK SHIP CONDITION. CLASS (DNV-GL) IS IN AGREEMENT WITH THIS COURSE OF ACTION. 74 SOLAS 14 CONS CHP. II-1/41.1.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 10 July 2019
Resolved 10 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 June 2019
Resolved
1430-ELECTICAL INSTALLATIONS SHOULD BE SUCH THAT ALL ELECTICAL AUX SERVICES NECESSARY FOR MAINTAINING THE SHIP IN NORMAL OPERATION AND HABITABLE CONDITIONS WILL BE ENSURED WITHOUT RECOURSE TO THE EMERGENCY SOURCE OF ELECTICAL POWER. A MAIN SOURCE OF ELECTRICAL POWER OF SUFFICIENT CAPACITY TO SUPPLY ALL THOSE SERVICES MENTIONED IN REG 40.1.1 SHALL BE PROVIDED. THIS MAIN SOURCE OF ELECTRICAL POWER SHALL CONSIST OF AT LEAST TWO GEN SETES. THIS SHIP HAS ONLY ONE MAIN GENERATOR OPERATIONAL AND INTENDS TO USE THE EMERGENCY GEN AND SHAFT GENERATOR AS ALTERNATE MEANS OF RESTORING POWER AND MAINTAINING NORMAL OPERATIONS IN THE EVENT OF A BLACK SHIP CONDITION. CLASS (DNV-GL) IS IN AGREEMENT WITH THIS COURSE OF ACTION. 74 SOLAS 14 CONS CHP. II-1/41.1.1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 June 2019
Resolved 9 July 2019
Resolution: Class report received. E-mail sent to vessel 09JUL19.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 7 June 2019
Resolved
Each loading arm and each transfer pip system, including each metallic hose, must not leak under static liquid pressure at least 1 1/2 times the MAWP. The frequency of this test must be conducted annually. Provide proof of hydrostatic test for metallic hose used for oil transfers on board the vessel. Complete annual hydro test prior to next bunker operation in the United States.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 11 June 2019
Resolution: Master provided satisfactory pressure test of fuel, sludge and lube oil pipes in the bunker station completed.