DOGHOUSE

DOGHOUSE is a 2003 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in April 2026, along with 66 deficiencies and 1 casualty investigation in 2008.

Records from 2008 to 2026. Most recent: inspection, 2 April 2026.

Built
2003
Last inspected
2 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF2822
662296
Flag
UNITED STATES
Maury page id
psix-662296

Documentation record

Registered dimensions (L × B × D)54.0 ft × 17.0 ft × 7.0 ft
Registered tonnagegross 43 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHARRIS BOATWORKS INC · MARSHALLBERG, NC, UNITED STATES · built 2003
Hull materialWood
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portWANCHESE, NC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 6 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Simplified, Gross Ton
34 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

2 April 2026 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8324655
10 March 2026 Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8322892
25 February 2025 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8081411
23 February 2024 Drydock Exam · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7867543
27 February 2023 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7642533
14 February 2023 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7636005
30 January 2023 Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7630967
19 May 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7454636
13 April 2022 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7421647
26 May 2021 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7219026
20 April 2021 Appeal
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7180087
15 April 2021 DAPI Audit · Annual Inspection · Special
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7174538
6 January 2021 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7120692
9 November 2020 Type not recorded
No type recorded · USCGC NATHAN BRUCKENTHAL (WPC-1128) · USCG East District (CGD-E) · Activity 7092625
25 February 2020 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6915828
29 May 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6697774
14 March 2019 Type not recorded
No type recorded · USCGC NATHAN BRUCKENTHAL (WPC-1128) · USCG East District (CGD-E) · Activity 6648005
18 December 2018 Examination of Repairs · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6599823
17 April 2018 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6398578
22 February 2018 Type not recorded
No type recorded · USCGC LAWRENCE O. LAWSON (WPC 1120) · USCG East District (CGD-E) · Activity 6364650
22 June 2017 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6188364
13 April 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6123968
7 December 2016 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6054039
31 July 2016 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5940950
26 April 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5862623
22 February 2016 Type not recorded
No type recorded · USCGC NANTUCKET (WPB 1316) · USCG Southeast District (CGD-SE) · Activity 5825776

Deficiency record · 66

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2024 Resolved
Vessel owner must ensure that inspection and tests are performed on portable fire extinguishers. Vessel's fire extinguishers have not had annual servicing required by NFPA 10. Ensure fire servicing is completed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2024
Resolved 15 March 2024
Resolution: Annual servicing conducted on portable fire extinguishers.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 March 2024 Resolved
Radio Safety Telephoney Certificate is expired. IAW 47CFR80
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 15 March 2024
Resolution: Radio equipment inspected by FCC inspector and certificate issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2024 Resolved
Life jacket lights are expired. Ensure lights are affixed to all life jackets. While on an Oceans route, vessel may not exceed 11 persons on board.
Action required: 705 - Other - as specified
Due 4 April 2024
Resolved 27 March 2024
Resolution: New light have been installed on all life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2024 Resolved
Life buoy battery must be replaced annually.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 15 March 2024
Resolution: Battery replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 March 2024 Resolved
Life float paint is faded and is missing separators between floats.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 15 March 2024
Resolution: Paint applied and canvas separator installed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 March 2024 Resolved
First aid kit has expired medications. Ensure first aid kit meets requirements in 46CFR160.041.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2024
Resolved 15 March 2024
Resolution: New first aid kit purchased and placed in service.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2024 Resolved
Alcohol test strips must be kept onboard vessels if they are further than 2 hrs from port. Alcohol test strips are expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 27 March 2024
Resolution: Alcohol test strips are on board.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 February 2023 Resolved
Install fire detection in forward accommodation space, head, store room and salon. Ensure system is audible from operating station. Vessel is limited to Limited Coastwise Route; not more than 20 miles from a harbor of safe refuge. IAW 46CFR181.405.
Action required: 705 - Other - as specified
Due 14 February 2023
Resolved 27 February 2023
Resolution: Fire Detection Installed. Witnessed Operation. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 February 2023 Resolved
01 life float onboard has faded paint. Retro is inadequate and is missing a float light. Ensure dunnage is installed to separate life floats. IAW 46CFR180.200/46CFR180.137(F)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2023
Resolved 27 February 2023
Resolution: Owner repainted, installed retro, light, dunnage. Verified while in attendance all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 February 2023 Resolved
Ring buoy has faded retro. Battery for float light is not marked and vessel name is faded on life ring. IAW 46CFR180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2023
Resolved 27 February 2023
Resolution: Mariking corrected. Verified on scene.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 February 2023 Resolved
High water alarm visual indicator is non-operable at operating station. IAW 46CFR182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2023
Resolved 27 February 2023
Resolution: Repaired. Verified operation while attending.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 14 February 2023 Resolved
MF Radio is inoperable and Radio Telephony Certificate is expired. Vessel is limited to operations no more than 20 miles from shore.
Action required: 705 - Other - as specified
Due 14 February 2023
Resolved 27 February 2023
Resolution: Certificate renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2023 Resolved
Electrical hazards throughout. Wire supports in engine room must be installed every 24 inches. Dead end wiring in head. Outlet cover in accommodation space. IAW 46CFR183.220/46CFR183.340(B)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2023
Resolved 27 February 2023
Resolution: Electrical hazards fixed. Verrified while attending.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 February 2023 Resolved
Vessel is required to undergo a dry dock and internal structural examination at least once every two years. Vessel is passed due date for dry dock and internal structural examination as listed on the COI. Vessel may operate as an uninspected passenger vessel per COI and carry no more than six passengers until dry dock and internal structural exam is completed and credited by Coast Guard Marine Inspectors IAW 46CFR176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2023
Resolved 7 February 2023
Resolution: Vessel completed credit DD/ISE.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 April 2022 Resolved
For a life float - Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition; MI found one unapproved buoyant apparatus while conducting COI. **Vessel is limited to 15 total persons onboard while on oceans route until additional approved life float is installed that meets approval 160.027. Full passenger count is authorized as per 46CFR180.204(d)(2) while not more than 3 miles from land.** Life Float install/approval shall be as per 46CFR180.200(a)(2) and 46CFR202(a)(2).
Action required: 705 - Other - as specified
Resolved 19 May 2022
Resolution: Company had additoinal life float that was taken off vessel for grab line replacement. Objective evidence provided and def cleared.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 April 2022 Resolved
EPRIB Battery expired and Antenna found wasted. Vessel restricted to no more than 3NM from shore IAW 46CFR180.64.
Action required: 705 - Other - as specified
Resolved 20 April 2022
Resolution: Owner operator provided objective evidence of compliance, registration, testing and mounting.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 April 2022 Resolved
[name withheld] life float cracking in several areas. Make repairs as per manufacturer recommendations IAW 46CFR180.200(a)(2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 20 April 2022
Resolution: Life float repairs conducted using JIM BUOY repair kit as per objective evidence.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 April 2022 Resolved
Machinery guard for port and STBD MDE missing. Install proper machinery guards IAW 46CFR177.960.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 20 April 2022
Resolution: Mach. guards installed port and stbd engines. Additional repairs were made to properly secure and add foam edge proptectors on sharp edge follwoing MI inspection, SAT.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 April 2022 Resolved
Fixed fire boy servicing tag at bottle; no inspections date, and new tag required at pull station (currently has 2020 date) IAW 46CFR176.810(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 20 April 2022
Resolution: OBX fire attended vsl and placed new service tags on pull station and fixed bottle in engine room.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 April 2021 Resolved
VESSEL STERN LIGHT & MASTHEAD LIGHT ARE INOP. VESSEL RESTRICTED TO DAYLIGHT HOURS AND/OR NON-LIMITED VISIBILITY. IAW 33CFR83.22
Action required: 705 - Other - as specified
Resolved 27 May 2021
Resolution: Lights now working properly.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 16 April 2021 Resolved
PROVIDE ONBOARD UPDATED/ NEW SAFETY RADIO CERT ISSUED BY FCC FOR INSPECTION OF VHF, EPIRB AND/OR MF/INMARSAT.IAW 47CFR80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 26 May 2021
Resolution: Radio cert to be updated once new install of INMARSAT. Informed operator to provide this office of copy once received. Confirmed with FCC for order of new equipment.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 16 April 2021 Resolved
PROVIDE MARINE RADIO OPERATOR PERMIT. IAW 47CFR80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 26 May 2021
Resolution: New MROP received.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 16 April 2021 Resolved
PROVIDE EVIDENCE OF SHORE-SIDE DOCUMENTATION FOR VOYAGE PLAN AND PAX COUNT. IAW 46CFR185.502 & .503
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 26 May 2021
Resolution: Procedures provided onboard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2021 Resolved
PROVIDE ONBOARD VESSEL LOG THAT DOCUMENTS DRILLS AND EPIRB TESTS WITH DATE TESTED, DESCRIPTION, TNG TOPICS. IAW 46CFR185.728 & .520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 26 May 2021
Resolution: Log and drills now iaw with regulations.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 April 2021 Resolved
BILGE HIGH LVL ALARM (VISUAL) IS INOP, REPAIR TO SATISFACTION OF CA. IAW 46CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 26 May 2021
Resolution: Bilge high level alarm now working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2021 Resolved
BILGE AUTOMATIC DISCHARGE INDICATOR LIGHT IS INOP, REPAIR TO THE SATISFACTION OF CG. IAW 46CFR182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 26 May 2021
Resolution: Bilge indicator light now working properly.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 16 April 2021 Resolved
PROVIDE ONBOARD MUSTER & EMERGENCY INSTRUCTIONS INCLUDING CROSSING THE BAR, HAZ. WX. IAW 46CFR185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 26 May 2021
Resolution: Onboard muster and instructions now onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 April 2021 Resolved
PROVIDE MEANS OF PROTECTION FROM ROTATING MACHINERY IN E.R., SPECIFICALLY SHAFT. IAW 46CFR182.200
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2021
Resolution: Rotating machinery guards now installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 April 2021 Resolved
PROVIDE HANDLE OR SIMILAR MEANS FOR OPENING ESCAPE HATCH TO E.R. IAW 46CFR177.500
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2021
Resolution: Handle installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 April 2021 Resolved
MARK LIFEBUOY W/ VESSEL NAME. IAW 46CFR180.70
Action required: 10 - Deficiency Rectified
Resolved 16 April 2021
Resolution: Lifebuoy marked.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 April 2021 Resolved
REMOVE FUEL/OIL FROM BILGES. IAW 46CFR176.830
Action required: 10 - Deficiency Rectified
Resolved 19 April 2021
Resolution: Bilges now cleaned.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 April 2021 Resolved
PROVIDE UPDATED PUBLICATIONS TO INCLUDE CHARTS, COAST PILOT, CG LIGHT LIST, TIDE TABLES, CURRENT TABLES FOR INTENDED ROUTE(S). IAW 46CFR184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2021
Resolution: Pubs/charts now onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 16 April 2021 Resolved
PROVIDE PERMANENT MEANS OF STOWAGE OF LIFE FLOATS AND ENSURE ALL EQUIPMENT IS FITTED. IAW 46CFR180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 26 May 2021
Resolution: Operator instead returned existing life float to installed bracket. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 16 April 2021 Resolved
REPLACE WEAKLINK FOR LIFEFLOATS. IAW 46CFR180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 26 May 2021
Resolution: Weaklinks replaced. Operator will keep tags in binder onboard.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 April 2021 Resolved
PROVIDE A MEANS FOR PREVENTING VENTILLATION TO THE ENGINE SPACE IN CASE OF FIRE. IAW 46CFR182.465
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 17 June 2022
Resolution: DD Sup. approved current closures on simular vessel. SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2020 Resolved
Found expired life jacket lights. Replace all expired lights.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 February 2020
Resolution: Verified new lights on life jackets with satisfactory arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 25 February 2020 Resolved
Found survival craft not stowed and arranged satisfactory. Stow required life floats with all required equipment.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 February 2020
Resolution: Verified life floats were stowed satisfactory and arranged with all required equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2020 Resolved
Found ring life buoy not marked with name of vessel. [name withheld] IAW cite.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 February 2020
Resolution: Verified ring life buoy was marked satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 February 2020 Resolved
Found all around NAV light inoperable. Fix Light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2020
Resolution: All nav lights operational.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 February 2020 Resolved
Found COI and Stability Letter not posted. Post COI and Stability Letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2020
Resolution: COI and Stability Letter now posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2020 Resolved
Found life jacket donning placard not posted. Post placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2020
Resolution: Life jacket donning placcard posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 February 2020 Resolved
Found expired first aid kit. Replace first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 February 2020
Resolution: Verified satisfactory first aid kit.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 February 2020 Resolved
Provide evidence of fire serving records.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2020
Resolution: Fire servicing records provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 February 2020 Resolved
Provide valid FCC Station License.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2020
Resolution: FCC Station License approved, final paperwork pending. Approval number from FCC on file.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2019 Resolved
Found floating waterlight inoperable. Repair waterlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 13 June 2019
Resolution: Waterlight repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 May 2019 Resolved
Found 15 pax lifefloat unserviceable. Replace lifefloat.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 13 June 2019
Resolution: Master procured a new lifefloat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 May 2019 Resolved
Found fire servicing expired. Complete fire servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 13 June 2019
Resolution: Fire servicing has been completed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 May 2019 Resolved
Found visual indicator for high bilge alarm inop. Repair visual indicator.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 June 2019
Resolution: Visual indicator repaired; test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2019 Resolved
Found stbd fuel fill hose cracked; replace hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 13 June 2019
Resolution: A new fuel fill hose has been installed.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 29 May 2019 Resolved
Vessel unable to get underway for drills due to maintenance work being conducted on the engines; conduct drills.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 13 June 2019
Resolution: Vessel got underway and conducted drills.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 May 2017 Resolved
Found FCC Radio Safety Certificate expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 22 June 2017
Resolution: Valid FCC Safety Radio Certificate is on board with and expiration date of 06/07/2022.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 May 2017 Resolved
Found navigation running lights inop. Vessel is restricted to daytime operations until lights have been repaired.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 22 June 2017
Resolution: New navigation lights have been installed and tested; sat.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 4 May 2017 Resolved
Found penetration in fwd engine room bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 22 June 2017
Resolution: Bulkhead penetration has been filled.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 4 May 2017 Resolved
Found MSD three way valve not functioning properly. Secure OVBD valve within 3 miles of shore and while transiting non-discharge zones.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 22 June 2017
Resolution: A new three-way valve has been installed.
Lifesaving › Lifefloat › Serviceable
Issued 4 May 2017 Resolved
Found on 15 person lifefloat no longer serviceable. Removed and destroyed life float. Vessel operations restricted to carrying not more than 15 people.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 22 June 2017
Resolution: A new lifefloat has been installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 April 2017 Resolved
Found ring life buoy not properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2017
Resolution: Ring Lifebuoy has been properly labeled.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 13 April 2017 Resolved
Found port and stbd fuel fills not bonded to fuel tanks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 June 2017
Resolved 22 June 2017
Resolution: Fuel fill connections have been bonded to the vessel's bonding strap.
Communications › Radio Communications › EPIRB
Issued 26 April 2016 Resolved
406 battery expired.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Battery was replaced and has an expiration date of 2021.
Communications › Radio Communications › EPIRB
Issued 26 April 2016 Resolved
406 hydrostatic release expired.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: The hydrostatic release was replaced and has an expiration date of Feb 2018.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 April 2016 Resolved
Current consortium enrollment not on board.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Current consortium enrollment was provided as required.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 April 2016 Resolved
Alcohol test strips expired.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: The alcohol test strip(s) were provided as required.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 26 April 2016 Resolved
CPR/First Aid card expired.
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 31 July 2016
Resolution: Provided valid CPR/First Aid card
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 26 April 2016 Resolved
Life jackets require water lights.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: All life jacket lights were replaced as required.
Lifesaving › Lifefloat › Serviceable
Issued 26 April 2016 Resolved
Life floats require new paint/retro/markings.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Both life floats were re-painted with approved paint, new retro and markings were also placed on them as required.
Engineering › Bilge Water Management System › Not Operational
Issued 26 April 2016 Resolved
High water visual alarm not operational.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: High water visual alarm was working and tested properly as required.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 April 2016 Resolved
Manual override not operating properly.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Manual over ride switch for per-engineered fireboy system was replaced and tested properly.

Casualty record · 1

31 January 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3139863
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.