Records from 2016 to 2022. Most recent: inspection, 18 October 2022.
Inspection history · 23
18 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579524
4 July 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7244033
21 May 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7202930
19 May 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7200884
29 April 2021
Deficiency Check · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7181656
11 April 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6655586
1 August 2018
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6496388
28 July 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6493313
24 July 2018
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6489032
23 July 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6482309
14 July 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6466553
11 July 2018
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6474050
22 June 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6448112
21 June 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6456480
10 October 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6284826
6 September 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6260701
16 August 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6242577
16 April 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6127092
10 April 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6120513
28 August 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5985259
19 August 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5977001
8 June 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5901457
3 June 2016
ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5896038
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 30 April 2021
Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS. THE CO2 SYSTEM RECEIVED SUBSTANDARD SERVICING ON 3/17/2021. USCG IDENTIFIED 6 HEAVILY CRACKED AND KINKED HOSES.
THE SYSTEM NEEDS TO BE SERVICED BY A 3RD PARTY MARITIME FIREFIGHTING SERVICING COMPANY WITH ALL REPAIRS MADE THAT RETURN THE SYSTEM TO FULL OPERATION. THE TECHNICAL REPORT NEEDS TO BE SUBMITTED TO CLASS FOR INITIAL APPROVAL AND CLASS WILL SUBMIT TO USCG FOR FINAL APPROVAL.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2021
Resolved 1 May 2021
Resolution: SERVICING COMPANY COMPLETED FULL TEST/INSPECTION ON HIGH PRESSURE CO2 SYSTEM.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2021
Resolved
THE MEANS OF CONTROL OF ANY GAS FIXED FIRE FIGHTING SHALL BE ACCESSIBLE AND EASY TO OPERATE. AT EACH LOCATION THERE SHALL BE CLEAR INSTRUCTION FOR THE OPERATION OF THE SYSTEM. PLACARDING AT THE REMOTE OPERATING STATION IS NOT CLEAR ON HOW TO SEND CO2 TO THE ENGINE ROOM.
Action required: 10 - Deficiency Rectified
Due 30 April 2021
Resolved 30 April 2021
Resolution: PLACARDING ADDED TO THE STATION
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2021
Resolved
The main steering gear and rudder stock shall be capable of putting the rudder over from 35 degrees on either side to 30 degrees on the other side in no more than 28 seconds. During operational test onboard time exceed over 60 seconds.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 29 April 2021
Resolved 29 April 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 April 2021
Resolved
The following basic principals underlie the regulations as appropriate having regard to the type of ships and the potential fire hazard involved, including containment and extinction of any fire in the space of origin. The CO2 room contains multiple bottles with kinked and damaged hose lines.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2021
Resolved 4 July 2021
Resolution: HOSES REPLACED AND SYSTEM INSPECTED BY 3RD PARTY SERVICING COMPANY. CONDITION OF CLASS ISSUED FOR BANK FEEDING THE CARGO HOLDS VALID UNTIL 01JUL2021.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 April 2021
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Inflatable liferafts were installed with straps around the liferaft containers which would prevent deploying of the liferafts.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 April 2021
Resolved 29 April 2021
Resolution: Ship's crew removed the straps that were found around liferaft containers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2018
Resolved
After any survey of the ship under regulations 7,8, 9 and 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey. PSCO noted main engine RPM equipment panel not functioning as designed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 July 2018
Resolved
Machinery spaces of category A shall be adequately ventilated to ensure that when machinery or boilers are operating and adequate supply of air is maintained to the spaces for the safety and comfort of personnel and the operation of the machinery. PSCO observed that the main ventilation ducting in engine is deteriorated and not supplying an adequate supply of air to the spaces as originally designed. SOLAS 74 (04) II-1/35
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2019
Resolution: Received class report attesting to operation of the ventilation ducts.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 11 July 2018
Resolved
An engineers’ alarm shall be provided to be operated from the engine control room and shall be clearly audible in the engineer’s accommodations. PSCO observed that the alarm is in a fault condition and is always on. SOLAS 74 (04) II-1/38
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2019
Resolution: Received class report attesting to repairs.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 11 July 2018
Resolved
An alarm system shall be provided indicating any fault requiring attention and shall be capable of sounding an audible alarm in the main machinery control room and indicate visually each separate alarm function at a suitable position. PSCO observed that the alarm monitoring panel section 6 and 9 in the main machinery control room is inoperable.
SOLAS 74 (04) II-1/51
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2019
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2018
Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. PSCO observed that the circuit breaker supplying power to the microwave oven in the galley is overheating and tripping causing a potential electrical and fire hazard.
SOLAS 74 (04) II-1/40.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 July 2018
Resolved
Electrical installations shall be such that all electrical auxiliary services necessary for maintaining the ship in normal operational and habitable conditions shall be ensured without recourse to the emergency source of power. PSCO observed that the No. 2 ship service generator was inoperable after numerous failed attempts to start.
SOLAS 74 (04) II-1/40.1.1 and II-1/41
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2018
Resolved
Surfaces with temperatures above 220 degrees Celsius which may be impinged as a result of an oil or fuel system failure shall be properly insulated. PSCO observed that the turbocharger to the No. 3 generator was not protected to prevent oil or fuel coming into direct contact with the turbocharger heated surface. SOLAS 74 (04) II-2/4.2.2.6
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 July 2018
Resolved
In addition to the requirements contained elsewhere in the present SOLAS regulations, ships shall be maintained in compliance with the mechanical requirements of a classification society with is recognized by the Administration. PSCO observed that the water cooling system for the emergency generator diesel engine was leaking coolant and showed signs to deterioration. SOLAS 74 (04) II-1/3-1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 11 July 2018
Resolved
Ventilator openings shall be provided with weather tight closing appliances. PSCO observed that the following ventilators closures were not weathertight due to missing or damage closing device equipment:
a)No. 2 Cargo Hold outboard vent cover is damaged with one dog bolt missing;
b)No. 1 Cargo Hold inboard vent cover is damaged with one dog bolt missing;
c)Vent closing device to AHR Tunnel ventilator is missing
ICLL(66) Regulation 19
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 July 2018
Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO observed that the fire hydrant valve handle in way of the No.3 Fire Box port side was broken which caused fire hydrant to become inoperable in an emergency situation.
SOLAS 74 (14) II-2/14.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 11 July 2018
Resolved
In addition to the requirements contained elsewhere in the present SOLAS regulations, ships shall be maintained in compliance with the mechanical and electrical requirements of a classification society that is recognized by the administration. PSCO observed that the gantry crane emergency stops are inoperable causing a potential safety hazard to the crew.
SOLAS 74 (04) II-1/3-1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 July 2018
Resolved
All survival craft shall be stowed fully equipped as required by this chapter and the code. And operational compass which is luminous or provided with suitable means of illumination. PSCO noted that the vessel had 02 loose wires hanging down form the compass, which prevented that compass from being illuminated.
SOLAS 74 (04 CONS) III/13.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 July 2018
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/41 or II-1/43, as appropriated. PSCO noted that emergency lighting was in-operational in various places around the vessel.
SOLAS 74(14 CONS) III/11.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 July 2018
Resolved
The operator of each self-propelled vessl12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these rules. PSCO noted that the vessel is missing the navigation rules.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2018
Resolution: Received Class Report and attended vessel to verify that deficiency had been properly rectified.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 22 June 2018
Resolved
ach Administration shall, for the purpose of preventing fatigue require that watch systems are so arranged that the
efficiency of all watchkeeping personnel is not impaired by fatigue and that duties are so organized that the first watch at the commencement of a voyage and subsequent relieving watches are sufficiently rested and otherwise fit for duty. Vessel is operating with an attended machinery space and only two officers in charge of an engineering watch. Previous Recognized Organization classification for periodically unattended machinery spaces was removed upon failure of vessel's watch call/alarm system. The posted schedule has each officer in charge of an engineering watch standing 12 hours of duty a day both in port and at sea. Total work hours for a 7 day period is 84 hours. Vessel cannot provide records of daily hours of rest for seafarers to PSC Officers.
Def Code - 30ac
Action required: 30 - Ship detained
Due 22 June 2018
Resolved 2 July 2018
Resolution: Vessel provided satisfactory documentation of onsigning 3rd Engineer verified by attending PSCO's.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 22 June 2018
Resolved
Administrations shall require that records of daily hours of rest of seafarers be maintained to allow monitoring and verification of compliance with the provisions of Section A-VIII/1. The seafarers shall receive a copy of the records pertaining to them, which shall be endorsed by the master and by the seafarers. Vessel cannot provide any records of seafarer rest to PSC Officers. Def Code - 17 ac
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2018
Resolved 2 July 2018
Resolution: Vessel provided satisfactory documentation of onsigning 3rd Engineer verified by attending PSCO's.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 22 June 2018
Resolved
All persons who are assigned duty as officer in charge of a watch and whose duties involve designated safety, prevention of
pollution and security duties shall be provided with a rest period of not less than 77 hours in any 7 day period. Vessel is currently operating with an attended machinery space watch schedule having only two officers in charge of an engineering watch. The posted schedule has each officer standing 12 hours of duty a day both in port and sea. Total work hours for a 7 day period is 84 hours. Vessel cannot provide records of daily hours of rest for seafarers.
Def Code - 17 ac
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2018
Resolved 2 July 2018
Resolution: Vessel provided satisfactory documentation of onsigning 3rd Engineer verified by attending PSCO's.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 22 June 2018
Resolved
In the case of a lifeboat arranged for free-fall launching, at least three months during an abandon ship drill the crew shall board the lifeboat, properly secure themselves in their seats and commence launch procedures up to, but not including, the actual release of the lifeboat. The lifeboat shall then either be free-fall launched with only the required operating crew on board, or lowered into the water by means of the secondary means of launching with or without the operating crew on board. In both cases, the lifeboat shall thereafter be maneuvered in the water by the operating crew. Due to the inoperable recovery system on the free-fall the lifeboat had not be maneuvered since September 13th, 2017. Def Code - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2018
Resolved 2 July 2018
Resolution: Vessel conducted a lifeboat abandon ship/manouvering drill by shoreside crane with satisfactory results.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 22 June 2018
Resolved
Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. The vessel's recovery system has been inoperable since December 19th 2017. The vessel's has multiple Flag State Dispensation Letters extending the date to be repaired but states when parts are available. The Master provided an email with information stating the parts are in Houston but management decided to delay repairs until another port of call.
Def Code - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2018
Resolved 2 July 2018
Resolution: Vessel completed repairs. Conducted load test with Coast Guard and Class.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 22 June 2018
Resolved
Provision shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery. PSCO observed excessive oil leaks originating from engine room machinery leading to oil accumulating in the bilge well.
Def Code - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2018
Resolved 2 July 2018
Resolution: Class Society cleared deficiency
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 22 June 2018
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker). PSCO observed paint and other flammable liquids being stowed in the bosun stores.
Def Code - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2018
Resolved 2 July 2018
Resolution: Class Society resolved