Records from 2004 to 2026. Most recent: inspection, 26 March 2026.
Documentation record
Registered dimensions (L × B × D)42.0 ft × 13.0 ft × 4.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderP L JONES BOATYARD · FISHING CREEK, MD, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portROCK HALL, MD
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
26 March 2026
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8333597
24 April 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8126624
5 January 2024
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7845549
6 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7666394
28 February 2023
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7644211
8 April 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7428800
26 March 2021
Construction Oversight · Administrative Inspection · Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7163352
19 March 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7163368
22 October 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7082597
6 April 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6935877
12 March 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6921406
31 January 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6617917
27 March 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6386241
28 March 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6113414
23 February 2017
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6097609
30 March 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5845950
11 March 2014
Type not recorded
No type recorded · Station Annapolis · USCG East District (CGD-E) · Activity 4814326
26 September 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4154400
3 August 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4104122
30 March 2010
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3711206
23 February 2009
DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3422545
31 March 2008
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3174602
26 March 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3172064
29 March 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2898203
4 April 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2616699
15 March 2006
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2613420
5 April 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2331447
1 August 2004
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2242155
19 February 2004
COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2009230
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 April 2024
Resolved
A hatch cover must be secured to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Hatch covers are missing captive chains/securing devices.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 27 April 2024
Resolution: Received photographic evidence from vessel rep of securing devices for the hatch covers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2024
Resolved
A vessel must carry one floating waterlight for the ring buoy.
The battery for the floating waterlight is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 27 April 2024
Resolution: Received photographic evidence from vessel rep of new battery with 2026 expiry date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation.
Marking for fuel shutoff valves is faded and no longer fully legible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 27 April 2024
Resolution: Received photographic evidence from vessel rep of redone markings for the fuel shutoffs.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 April 2024
Resolved
At each inspection all unsafe practices must be corrected.
Flexible hose connected to thru-hull valve for water washdown station is dry rotting/cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 27 April 2024
Resolution: Received photographic evidence from vessel rep of the hose replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 April 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (3) Coast Guard Light List; (4) Tide tables. Extracts from the publications listed above for the areas to be transited may be provided.
Tide tables and light list onboard at time of inspection were not up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 27 April 2024
Resolution: Received photographic evidence from vessel rep of new up-to-date light list and tide tables.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 August 2020
Resolved
Each life float required on a vessel by this part must be approved under approval series 160.027. The life float did not have a visible nameplate displaying the data required by 46CFR160.010-8, inhibiting the ability for the life float specifications to be verified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 22 October 2020
Resolution: Life Float renewed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2020
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required and meet the minimum required classification for each space listed by Table 181.500(b) and other provisions of this section.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2020
Resolution: New 2-A:10-B:C purchased and mounted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 August 2020
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date on your COI. You failed to complete your annual inspection within the required timeframe. Failure to complete your inspection by August 31, 2020 will result in your deficiency being upgraded to Prior to Carrying Passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2020
Resolved 19 August 2020
Resolution: Inpsection conducted.
Lifesaving › Lifebuoys › Serviceable
Issued 28 March 2017
Resolved
Replace wasted life-ring
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 28 March 2017
Resolution: O/O replaced with new prior to departure from vessel.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 28 March 2017
Resolved
Replace expired battery in life-ring waterlight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 28 March 2017
Resolution: O/O replaced life-ring waterlight battery prior to departure from vessel.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 23 February 2017
Resolved
Vessel's cutlass bearing worn beyond 50% of original size. Replace/renew bearing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 February 2017
Resolution: Vessel owner replaced bearing with new cutlass bearing.
Documentation › Certificates/Documents › FCC SSL
Issued 23 February 2009
Resolved
Replace expired FCC Safety Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2009
Resolved 6 April 2009
Resolution: 06Apr09: Attende vessel as before, cleared deficiency listed above.
Lifesaving › Lifebuoys › Serviceable
Issued 23 February 2009
Resolved
Replace wasted lashings in way of life float mesh.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2009
Resolved 6 April 2009
Resolution: 06Apr09: Attende vessel as before, cleared deficiency listed above.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 February 2009
Resolved
Place Retro-reflective SOLAS tape on Life ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2009
Resolved 6 April 2009
Resolution: 06Apr09: Attende vessel as before, cleared deficiency listed above.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 April 2006
Resolved
Provide proof of enrollement in drug consortium for deck hand.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2006
Resolved 17 April 2006
Resolution: Operator provided proof of enrollement of deck hand in drug consortium.
Lifesaving › Lifefloat › Float-free Link
Issued 4 April 2006
Resolved
Prove proper installation of weak link assembly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2006
Resolved 17 April 2006
Resolution: Operator correctly configured weak link assembly.
Lifesaving › Hand Flares › Storage
Issued 4 April 2006
Resolved
Provide proof of storage container.
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 17 April 2006
Resolution: Operator provided a proper storage conatiner for flares.