HS CARMEN is a 2003 tank ship. The Coast Guard has recorded 4 inspections since 2016, most recently in November 2017, along with 4 deficiencies and 1 operational control.
Records from 2016 to 2017. Most recent: operational control imposed, 24 November 2017.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it131067 - Displacement, Ton 113033 - Dead Weight, Ton 62254 - Regulatory (Subpart C or D), Gross Ton 33873 - Regulatory (Subpart C or D), Net Ton 62254 - Convention (Subpart B), Gross Ton 33873 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
24 November 2017Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6312000
24 November 2017Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6312264
24 November 2017Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6312282
11 August 2016COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5990647
PSC Issued FORM B on 24NOV17 to the HS CARMEN IMO 9242120 for the #1 cargo pump leaking. Pump was not stopped as per the manufacturers instructions upon discovery of a leak the pump shall be shut down.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2017
Resolved 26 November 2017
Resolution: recieved class report attesting repairs.
Documentation › Safety Management System › Response Measures Documentation
Issued 24 November 2017Resolved
The company and ship shall comply with the requirements of the International Safety Management Code. The vessel's SMS requires an hourly inspection of the cargo pump room during cargo operations. During on of the inspections the watchstander reported that the #1 cargo pump was leaking. Per the manufacturer's instructions, upon discovery of a leak the pump is to be stopped and an investigation done to determine cause. Although a leak was reported, the pump was not shutdown and continued to be used for cargo ops. Recommend ISM audit be conducted. 74SOLAS(14) IX/3.1
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2017
Resolved 28 November 2017
Resolution: Recieved Flag report attesting to fact audit was conducted.
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations...Cargo pump #1 is leaking product. 74SOLAS(14) I/1
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2017
Resolved 25 November 2017
Resolution: Recieved class report attesting to repairs.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 24 November 2017Resolved
The last 1.0 meter of vapor piping must be painted in the sequence of red/yellow/red. The width of the red bands must be 0.1 meter and the width of the middle yellow band must be 0.8 meter. The vapor piping is missing a red band. 46 CFR 39.2001(h)
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 25 November 2017
Resolution: Recieved class report attesting to repairs.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National