Records from 2004 to 2026. Most recent: inspection, 27 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
27 March 2026
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8361613
29 July 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8198348
21 February 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7868050
1 September 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7782261
28 August 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7778607
20 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7653749
23 August 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7541464
6 October 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7327639
6 April 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7173661
30 October 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7087264
10 August 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6935894
30 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6932951
11 February 2019
Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6623762
7 June 2018
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6442288
12 April 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6392552
4 April 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6385247
13 April 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6136589
7 July 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5936791
18 March 2016
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5838068
28 May 2014
DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4864714
27 February 2012
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4251887
27 September 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4155388
26 August 2011
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4127649
3 September 2010
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3846756
19 March 2010
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3698811
25 March 2009
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3418526
11 March 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3162329
18 June 2007
Type not recorded
No type recorded · Station Curtis Bay · USCG East District (CGD-E) · Activity 2965844
3 May 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2921398
10 July 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2708718
2 May 2006
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2602825
5 April 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2329582
2 April 2004
Hull Examination · Plan Review "T" Boat · Initial Certification · Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2035951
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 27 March 2026
No resolution recorded
Be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Life float was not onboard the vessel at the time of inspection. Vessel may not carry passengers during cold water months.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 27 March 2026
No resolution recorded
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Number of persons allowed on upper deck was not marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 July 2025
No resolution recorded
The color of the buoyant apparatus must be primarily vivid reddish orange. The name of a vessel must be clearly marked or painted in clearly legible letters and numbers. On each life float and buoyant Apparatus. Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this subchapter on each side and ends.
The life float color was found faded, worn and discolored and retro reflective tape faded beyond effective use.
46CFR160.010-4(n) 46CFR 185.604(a) 46CFR 160.010-4(p)
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 July 2025
No resolution recorded
A vessel must be provided with bilge pumps IAW table 46CFR 182.520(a). On a vessel of at least 7.9 meters (26ft.) in length, a visual and audible alarm must be provided at the operating station to indicate a hight water level in each of the following normally unmanned spaces. Bilge pump in gen space only showed light when in manual mode and not in auto mode. Pump would pump auto mode but no light illuminated. Provide proof pump and lights work as perscribed
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2025
No resolution recorded
Flexible nonmetallic hose is meet SAE J 1942 standard, Hose fiting must meetSAE J 1945 standard.
Fuel hose(s) in fuel tank space were found with waste & corrosion
Replace as original.46CFR.720(e) 46CFR182.720(e)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2025 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 May 2024
Resolution: Retro tape was added to the life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Bilge pump and high water level alarm in the fuel compartment inoperable.
46CFR182.520(a)
46CFR182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2023
Resolved 1 September 2023
Resolution: Received video evidence of the operable high water level alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2023
Resolved
A vessel must have one or more ring life buoys. Ring life buoy on board is missing its plug.
46CFR180.70(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2023
Resolved 1 September 2023
Resolution: Reveived photographic evidence of the plug in the life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 August 2023
Resolved
The color of the buoyant apparatus must be primarily vivid reddish orange. The name of a vessel must be marked or painted in clearly legible letters and numbers:On each life float and buoyant apparatus. Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this subchapter on each side and end. The life float's color was wasted and eroded in different areas of the life float. The name of the vessel was not marked on the lifefloat and the retroreflective tape was wasted.
46CFR160.010-4(n)
46CFR185.604(a)
46CFR160.010-4(p)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2023
Resolved 10 October 2023
Resolution: Received photographic evidence the lifefloat has been painted, remarked, and the retro was replaced.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 August 2023
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum
number of passengers allowed on an upper deck must be
indicated at the entranceway to that deck.
46CFR185.602(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2023
Resolved 10 October 2023
Resolution: Received photographic evidence of the correct max passengers marked on the upper deck.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 August 2023
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Vessel's name was not marked on lifefloat paddles and it did not have a water light.
46CFR185.604(g)
46CFR180.175(d)
Action required: 10 - Deficiency Rectified
Due 28 August 2023
Resolved 28 August 2023
Resolution: Vessel's owner stenciled the vessel's name on the paddels as required and installed the waterlight as required on the lifefloat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 April 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces as described in this section. High water alarms did not function in cabin and forward cabin locations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2021
Resolution: Alarms fixed and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 April 2021
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Submersible electric bilge pumps in cabin and forward cabin locations did not work correctly.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2021
Resolution: Electric submersible bilge pumps fixed and test SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 April 2021
Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. Paddles were not lashed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 20 April 2021
Resolution: MI observed paddles correctly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 April 2021
Resolved
Each flare carried to meet this section must be stowed in a portable watertight container marked as required by §185.614 of this chapter, carried at the operating station. Container was not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 20 April 2021
Resolution: Water tight container purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 April 2021
Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 3/8 inch lanyard, resistant to deterioration from ultraviolet light, and at least 18 feet in length. Line was not of the required length.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 20 April 2021
Resolution: Line extended to proper length.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 April 2021
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Masthead light lens was shattered.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 20 April 2021
Resolution: Masthead light replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2021
Resolved
Electrical equipment on a vessel must be installed and maintained too protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Loose wiring observed throughout the engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 20 April 2021
Resolution: Loose wiring properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 October 2020
Resolved
Each vessel constructed of a material other than wood certificated to operate on a lakes, bays, and sounds route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. One of the two 15 person life floats was wasted. Total persons allowed during cold water months is reduced to 30.
46CFR180.207
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2021
Resolved 6 October 2021
Resolution: O/Op advised life float was not replaced. Amended COI to reflect cold water restriction of 30 totals persons aboard and reduced life float count.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 August 2020
Resolved
Each vessel constructed of a material other than wood certificated to operate on a lakes, bays, and sounds route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. Vessel's life float was wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 1 November 2020
Resolution: New def issued to reflect reduction in pax count to account for 1 remains SAT life float.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2019
Resolved
Vessel navigation lights must be in compliance with navigation rules. Prove proper operation of anchor light.
46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2019
Resolved 15 May 2019
Resolution: Vessel Owner provided proof of operational anchor light - ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2019
Resolved
Vessel must carry 3 hand red and 3 orange smoke flares or substituted red flares. All distress signals onboard are expired. Provide adequate /required distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2019
Resolved 15 May 2019
Resolution: Vessel Owner provided proof of 6 newly purchase red flare distress signals - ALL SAT.
Lifesaving › Lifefloat › Serviceable
Issued 12 April 2018
Resolved
Replace or repair 01 15-person life float. Passenger count is reduced to 28 passengers and 2 crew until this is resolved.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2018
Resolved 7 June 2018
Resolution: Verified installation of new 15 person life float.
Lifesaving › Lifefloat › Float-free Link
Issued 12 April 2018
Resolved
Apply retro-reflective tape and properly mark 15-person life float. Properly attach weak link to vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2018
Resolved 7 June 2018
Resolution: Verified reto reflective tape and installation of weak-link to vessel.
Engineering › Bilge Water Management System › Not Operational
Issued 12 April 2018
Resolved
Prove proper operation of forward high level alarm.
Action required: 705 - Other - as specified
Due 26 April 2018
Resolved 12 April 2018
Resolution: Verified proper operations of forward bilge high level alarm.
Communications › Alarms/Indicators › High Water Alarm
Issued 13 April 2017
Resolved
Fuel tank space high water alarm does not operate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 13 April 2017
Resolution: O/O proved proper operation.
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 April 2017
Resolved
Replace retroreflective tape on life floats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 13 April 2017
Resolution: Retroreflective tape was replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 July 2016
Resolved
Anchor light needs to be replaced.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 13 July 2016
Resolution: Received photo of functioning anchor light. Deficiency cleared.
Lifesaving › Lifefloat › Markings
Issued 26 August 2011
Resolved
Both life floats need new SOLAS reflective tape.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2011
Resolved 1 September 2011
Resolution: Installed new SOLAS reflective tape.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 26 August 2011
Resolved
Missing CO2 Fire Extinguisher type II in the open bridge. Install new fire extinguisher.
Due 2 September 2011
Resolved 1 September 2011
Resolution: Installed new fire extinguisher in the flying bridge.
Engineering › Steering Gear System › Rudder
Issued 26 August 2011
Resolved
Port side rudder post leaking. Adjust to minimize water leak.
Condition: Improper/Lack of Maintenance
Due 2 September 2011
Resolved 1 September 2011
Resolution: Tighten port rudder.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 August 2011
Resolved
Loose wires behind breaker panel and operator's console. Remove wires or connect them to their proper connection.
Condition: Improper/Lack of Maintenance
Due 2 September 2011
Resolved 1 September 2011
Resolution: Removed loose electrical wires.
Lifesaving › Lifefloat › Paddle
Issued 3 September 2010
Resolved
4' paddle missing from life float. Replace and ensure that oars are lashed as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2010
Resolution: Received a receipt from the owner showing that a new 4'' oar has been purchased for the vessel''s life float.
Documentation › Certificates/Documents › FCC SSL
Issued 3 September 2010
Resolved
FCC Safety Certificate expired, contact an FCC rep for recertification.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2010
Resolved 13 September 2010
Resolution: Received a current FCC Safety Certificate from the vessel owner showing that the vessel is now in compliance.
Communications › Audible Communications › Bell
Issued 25 March 2009
Resolved
Ships bell missing from control station. Aquire & install ships bell prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2009
Resolution: Ships bell purchased and being maintained onboard.
Communications › Alarms/Indicators › High Water Alarm
Issued 25 March 2009
Resolved
High water alarms in forward compartment and upper cabin compartment weak and barely audible. Replace as new prior to carrying passeners.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2009
Resolution: High water alarms replaced as required.
Construction/Loadline › Structures › Superstructure
Issued 25 March 2009
Resolved
Bridge windows on port & starboard side of cabin cracked. Replace as new within 30 days to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2009
Resolved 1 June 2009
Resolution: Both bridge windows replaced as required.
Lifesaving › Hand Flares › Not on Board
Issued 11 March 2008
Resolved
Replace expired flares (2) with approved type flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2008
Resolved 13 May 2008
Resolution: Conducted def-ck and cleared above deficiency.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 March 2008
Resolved
Repair/replace waterlight for lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2008
Resolved 13 May 2008
Resolution: Conducted def-ck and cleared above deficiency.
Lifesaving › Lifefloat › Paddle
Issued 11 March 2008
Resolved
Replace broken paddle for lifefloat at least 4' long.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2008
Resolved 13 May 2008
Resolution: Conducted def-ck and cleared above deficiency.
Communications › Alarms/Indicators › High Water Alarm
Issued 11 March 2008
Resolved
Repair/replace high water alarm indicators for the engine and fuel compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2008
Resolved 13 May 2008
Resolution: Conducted def-ck and cleared above deficiency.
Stability › Watertight Integrity › General
Issued 11 March 2008
Resolved
Attach lanyard to forward hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 March 2008
Resolved 13 May 2008
Resolution: Conducted def-ck and cleared above deficiency.
Communications › Alarms/Indicators › High Water Alarm
Issued 3 May 2007
Resolved
High level alarm for engine compartment visual indicator at steering station not operating. Repair as original.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 4 May 2007
Resolution: Received fax from O/Op showing purchase of replacement part for a bove deficiency.
Engineering › Bilge Water Management System › Pump
Issued 3 May 2007
Resolved
Lovett bilge pump in fuel compartment not discharging water when tested. Repair/replace with approved U/L bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2007
Resolved 4 May 2007
Resolution: Received fax from O/Op showing purchase of replacement part for a bove deficiency.
Construction/Loadline › Structures
Issued 12 April 2004
Resolved
Prior to carrying more than 12 passengers, provide Coast Guard approved hull structure plans.
Due 30 April 2004
Resolved 27 April 2004
Electrical › Electric Supply System (service)
Issued 12 April 2004
Resolved
Provide in line fuse for battery lead located as close as possible to the batteries. LEGACY COMPONENT DESC: Battery Installation
Due 12 May 2004
Resolved 19 May 2004
Communications › Alarms/Indicators
Issued 12 April 2004
Resolved
Provide smoke detector for generator space. LEGACY COMPONENT DESC: Fire Alarm
Due 12 May 2004
Resolved 19 May 2004
Documentation › Certificates/Documents
Issued 12 April 2004
Resolved
Provide FCC station license. LEGACY COMPONENT DESC: FCC SSL
Due 12 May 2004
Resolved 19 May 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 12 April 2004
Resolved
Provide sea rails on stove.
Due 12 May 2004
Resolved 19 May 2004
Fire Fighting › Structural - B Class Divisions
Issued 12 April 2004
Resolved
Provide low flame spread boundaries around cooking appliance.
Due 12 May 2004
Resolved 19 May 2004
Navigation › Piloting/Steering
Issued 12 April 2004
Resolved
Provide Coast Pilot.
Due 12 May 2004
Resolved 19 May 2004
Engineering
Issued 12 April 2004
Resolved
Provide discharge hose on hand bilge pump long enough to pump any compartment.
Due 12 May 2004
Resolved 19 May 2004
Fire Fighting
Issued 12 April 2004
Resolved
Provide lanyard on fire buckets.
Due 12 May 2004
Resolved 19 May 2004
Lifesaving
Issued 12 April 2004
Resolved
Post life jacket donning placard.
Due 12 May 2004
Resolved 19 May 2004
Lifesaving
Issued 12 April 2004
Resolved
Prior to operating at night, provide waterlight on ring buoy.
Due 12 May 2004
Resolved 19 May 2004
Engineering
Issued 12 April 2004
Resolved
Provide second hose clamp on port MDE exhaust.
Due 12 May 2004
Resolved 19 May 2004
Accommodation/Occupational Safety
Issued 12 April 2004
Resolved
Provide captive chain/line for aft hatch.
Due 12 May 2004
Resolved 19 May 2004