ROSALIA D'AMATO is a 2001 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in October 2018, along with 4 deficiencies and 3 operational controls.
Records from 2016 to 2018. Most recent: inspection, 11 October 2018.
This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it87338 - Displacement, Ton 74710 - Dead Weight, Ton 40562 - Convention (Subpart B), Gross Ton 26139 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
11 October 2018Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6559275
16 August 2017Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6242717
8 August 2017ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6233848
2 August 2017Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6228253
5 October 2016Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6017101
5 October 2016Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6017406
14 September 2016ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5990954
8 September 2016Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5995064
8 September 2016Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6003411
8 September 2016Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6005345
Fire Fighting › Combustible Materials › Insulation
Issued 8 August 2017Resolved
50ac, MARPOL Annex VI Reg 16.6.1, Each incinerator subject to this paragraph shall be approved by the administration taking into account the standard specification for shipboard incinerators developed by the organization. The refractory cement covering the fire bricks is failing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 16 August 2017
Resolution: Vessel sent in class documentation. See attached.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 September 2016Resolved
PSCO observed quick closing valve on the LSFO service tank blocked open with wood wedge, rendering the valve in-operable
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 16 September 2016
Resolution: Received Class Report from RINA Surveyor. Training provided to ship's crew on using quick closing device (QCV's). QI from Gallagher Marine Systems also attended. All QCV's were tested 13 September; block had been left accidentially.
Fire Fighting › Ventilation Systems › Fans
Issued 14 September 2016Resolved
PSCO observed ventilation motor to emergency generator room has been removed and wiring was severly damaged by fire.
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 16 September 2016
Resolution: Received report from RINA surveyor. Ventilation motor with fan propeller was assembled & restored. After reinstallation of electrical motor, fan was checked and tested sat.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 14 September 2016Resolved
PSCO observed 21 food rations were no longer servicable between port and starboard lifeboats.
Action required: 705 - Other - as specified
Due 14 September 2016
Resolved 15 September 2016
Resolution: Received verification that non serviceable food rations have been replaced.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.