MAURY USCG vessel records Sign in
← All vessels

TRANS CATALONIA

TRANS CATALONIA is a 2000 tank ship. The Coast Guard has recorded 48 inspections since 2000, most recently in October 2021, along with 24 deficiencies and 9 operational controls.

Records from 2000 to 2021. Most recent: inspection, 10 October 2021.

Built
2000
Last inspected
10 October 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9176694 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SINGAPORE
—
Maury page id
psix-6630

Inspections, by type

…with no type recorded15
Years with a record 15 calendar years (2000–2021)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5941 - Convention (Subpart B), Net Ton
19715 - Dead Weight, Ton
26941 - Displacement, Ton
13005 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ANDREW K Towing Vessel · MISLE 349103 · 26 July 2011 · activity 4095952GOLDEN MILLER Tank Ship · MISLE 390044 · 26 July 2011 · activity 4095952

Inspection history · 48

10 October 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7330133
19 September 2021 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7313901
20 September 2020 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7061635
18 September 2020 MARPOL Annex VI Survey · Ballast Water Examination · PSC B · COC-GAS Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7060680
24 November 2018 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6585701
6 August 2017 PII Safety Exam · Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6230422
23 June 2014 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 4899341
17 June 2014 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4890963
26 July 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4095952
11 February 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3943508
13 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3532935
12 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3535465
8 May 2009 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3470557
23 October 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3350088
9 May 2008 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3202493
29 April 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3195064
24 February 2008 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3149939
5 October 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3074068
1 June 2007 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2948864
9 March 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2884854
3 August 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2735364
25 July 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2726432
17 May 2006 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2651961
11 January 2006 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2578690
17 July 2004 ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2136228
20 May 2004 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2076564
27 February 2004 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2014252
28 December 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1970208
25 November 2003 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1954500
30 September 2003 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1917507
17 July 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1898013
4 July 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1834799
13 May 2003 Security Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1792766
9 May 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1789874
19 March 2003 Security Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1759518
17 March 2003 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1758573
9 March 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1754704
3 March 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1755718
1 January 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1725111
19 October 2002 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1692775
3 August 2002 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1656202
28 May 2002 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1622450
16 March 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1494528
30 July 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 292384
17 July 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 291985
4 July 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 279390
11 May 2000 Type not recorded
No type recorded · Activities Europe · Activity 277630
11 May 2000 Administrative
Administrative · Activities Europe · Activity 1049408

Deficiency record · 24

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 21 September 2021 Resolved
PSCO's observed 12 ppm VOC reading of butadiene around cargo tank hatch 7 stbd. Master shall provide operational and repair proposal to MSU Port Arthur, Class and Administration prior to cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 21 October 2021
Resolved 10 October 2021
Resolution: CARGO TANK WAS GAS FREED AND GASKETS WERE REPLACED. FOLLOWING REPLACEMENT A PRESSURE TEST WAS CONDUCTED SATISFACTORILY.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 September 2021 Resolved
Exhaust fan for the gas free room not operational.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 5 October 2021
Resolved 10 October 2021
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 September 2021 Resolved
1,3 Butadiene leak was found by Marine Chemist at the port side manifold, with highest concentrations 20ft forward of manifold.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2021
Resolved 21 September 2021
Resolution: Cleared via Class Report.
Deck/Cargo › Cargo Stowage › General
Issued 13 July 2009 Resolved
While discharging 2-ethyl-hexyl nitrate the vessel experiences a flash/flame alarm without cause. The vessel is required to submit a report of investigation concerning the incident. The report should address: 1.Chemical analysis of product. 2. Temp recorded at or near the incident. 3. Findings from inspection and testing of ships cargo systems. See Form B for full details.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 August 2009
Resolved 29 July 2009
Resolution: Received detailed investigation of over pressurization, attached in documentation section of this activity. Vessel shall follow best practices as shown in appendix 10B when transferring 2-Ethyl Hexyl Nitrate.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 5 October 2007 Resolved
Vessel lost stbd anchor while anchoring in Galveston Fairway Anchorage.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2007
Resolution: Received satisfactory class report.
Construction/Loadline › Structures › Superstructure
Issued 17 May 2006 Resolved
Foundation stanchion under cargo motor room was found to be broken . Requested class to inspect.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 3 August 2006
Resolution: Received satisfactory class report.
Deck/Cargo › Cargo Stowage › General
Issued 17 May 2006 Resolved
Vessel could not provide cert of inhibation in reference to sub O endorsment. IGC 17.8
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 August 2006
Resolution: Received copy of inhibition certificate.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 May 2006 Resolved
Fracture found on cargo deck light on starboard side over manifold. IGC 10.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 17 May 2006
Resolution: Fixture replaced prior to departure.
Construction/Loadline › Structures
Issued 20 May 2004 Resolved
Ventilation Dampers to engine room inoperable. 74Solas II-2/16.9 LEGACY COMPONENT DESC: Ventilators
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2004
Resolution: Received Class report attesting to satisfactory repairs to ventilation dampers.
Deck/Cargo › Vapor Control Systems
Issued 20 May 2004 Resolved
Vapor Control piping not properly labeled. 46 CFR 39
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 24 May 2004
Resolution: Received Class report attesting to proper painting of vapor control piping.
Construction/Loadline › Structures › Door
Issued 20 May 2004 Resolved
Motor room door not self-closing. IGC 3.6.2
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Resolution: Received Class report attesting to satisfactory repairs to motor room door.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 25 November 2003 Resolved
Repair #5 cylinder on main diesel engine to the satisfaction of class. LEGACY COMPONENT DESC: Cylinder
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2003
Fire Fighting
Issued 4 July 2003 Resolved
Crew was not able to demonstrate proper operation of Moss Gas Detection System, Crew to demonstrate operation to the satisfaction of Class Surveyor at next US Port.
Action required: 705 - Other - as specified
Due 7 July 2003
Resolved 14 July 2003
Resolution: Recieved class report, dated 14JUL03, stating MOSS gas detector was tested and found to be operating satisfactory
Lifesaving › Inflatable Liferafts
Issued 4 July 2003 Resolved
Crew is using the handrails to bring davit life raft along side. Crew to install some means to bring liferaft along side ad per LSA Code 4.1.4.1.2 to the satisfaction of Class Surveyor.
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 14 July 2003
Resolution: Recieved class reported, dated 14JUL03, stating two cleats were installed in order to hold life raft in place during launching.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 4 July 2003 Resolved
Two crewmembers did not have the proper Flag Endorsements. Endorsements onboard were older than 3 months as per STCW I/10.5. Copies of the new application for endorsements were faxed to vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2003
Resolved 4 July 2003
Lifesaving
Issued 17 July 2001 Resolved
AIR LOCK DOORS NOT SELF-CLOSING (IGC 3.6.2): INSTALL DOOR CLOSERS TO SATISFACTION OF CERTIFICATE OF FITNESS ISSUING AUTHORITY.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Deck/Cargo
Issued 11 May 2000 Resolved
PROVIDE TOXIC VAPOR DETECTOR SENSORS FOR PORTABLE INDICATORS.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Deck/Cargo
Issued 11 May 2000 Resolved
PROVE PROPER OPERATION OF FIXED GAS DETECTION SYSTEM.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Deck/Cargo
Issued 11 May 2000 Resolved
PROVE PROPER OPERATION OF OPEN/CLOSED INDICATORS ON BOTH LIQUID PIPES AT STARBOARD MANIFOLD.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Engineering
Issued 11 May 2000 Resolved
PROPERLY MARK EMERGENCY SHUTDOWN ON BRIDGE THAT IS CURRENTLY UNMARKED AT MAIN STEERING STATION.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Deck/Cargo
Issued 11 May 2000 Resolved
LABEL ALL EMERGENCY SHUTDOWN STATIONS SO THEY CAN BE VISIBLE FROM WORK AREAS BY CARGO CONTAINMENT SYSTEM AT MANIFOLDS.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Deck/Cargo
Issued 11 May 2000 Resolved
PROVE PROPER OPERATION OF AIR INTERLOCK AUDIBLE & VISUAL ALARMS AT MOTOR ROOM ENTRANCE.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Documentation
Issued 11 May 2000 Resolved
PROVIDE CERTIFICATE OF FINANCIAL RESPONSIBILITY PRIOR TO ENTRY TO U.S. WATERS.
Condition: Unknown
Due 11 June 2000
Resolved 9 June 2000
Documentation
Issued 11 May 2000 Resolved
PROVIDE PROOF OF FLAG STATE OR CLASS APPROVAL OF SOPEP PRIOR TO ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 11 June 2000
Resolved 9 June 2000

Ownership record