MAURY USCG vessel records Sign in
← All vessels

JOSCO NANJING

JOSCO NANJING is a 2003 freight ship. The Coast Guard has recorded 10 inspections since 2003, most recently in February 2017, along with 3 deficiencies and 3 operational controls, 1 with no removal date recorded.

Records from 2003 to 2017. Most recent: inspection, 4 February 2017.

Built
2003
Last inspected
4 February 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9281956 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
663169
Flag
HONG KONG
—
Maury page id
psix-663169

Inspections, by type

…with no type recorded5
Years with a record 5 calendar years (2003–2017)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it49216 - Dead Weight, Metric Ton
27162 - Convention (Subpart B), Gross Ton
16161 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

4 February 2017 Deficiency Check · Administrative Inspection · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6082690
3 February 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6080339
3 February 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6082528
17 August 2008 ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3299976
22 September 2005 ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2498467
20 July 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2433909
3 May 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2348526
11 October 2004 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2218536
11 December 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1962608
10 December 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1962117

Deficiency record · 3

Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 4 February 2017 Resolved
9800 Safety and Enviro Policy - The company and ship shall comply with the requirements of the international Safety Management Code. The company should establish an environmental protection policy which describes how objectives given in paragrah 1.2 will be achieved. Obj. evidence determined that company failed to provide to ship clear and doc guidance to manageme of treated sewage ISM 2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2017
Resolution: Vessel submitted class report attesting to class attendance and review of grey water management procedures while in port.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 4 February 2017 Resolved
0799 Fire Fighting Equip Following fire protection sys shall be kept in good order so as to ensure required performance if a fire occurs: .1 Structural fire protection including fire resisting divisions and protections of opening and penetrations in these divisions. Self closing A-0 door was inhibited by unapproved penetration of a sewage line. 74SOLAS(14CONS) II-2/14.2.1.1.1 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 4 February 2017
Resolution: Inspectors observed the removal of sewage line restoring the self closing condition to the A-0 boundry door to the steering gear room.
Fire Fighting › Fire Hoses › Condition
Issued 4 February 2017 Resolved
0720 - FFE- Fire-fighting systems and appliances shall be kept in good and working order and readily available for immediate use. 03 fire hoses found in severely degradaed condition. 74SOLAS(14CONS)II-2/14.2.1.2
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 4 February 2017
Resolution: Vessel crew conducted a functional test and fully replaced degraded hoses in the presence of attending marine inspectors.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.