Records from 2003 to 2010. Most recent: inspection, 15 February 2010.
Inspection history · 31
15 February 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3680129
14 July 2009
ISM Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3534437
2 February 2009
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3403723
26 May 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3217665
18 September 2007
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3060638
27 June 2007
ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2975456
15 May 2007
PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2929827
16 April 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2908660
14 February 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2872063
16 October 2006
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2801369
12 October 2006
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2799305
11 October 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2798391
2 October 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2792404
25 September 2006
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2786195
19 September 2006
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2781691
19 September 2006
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2781944
3 January 2006
Random ISPS/MTSA/PSC
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2556221
26 October 2005
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2522389
25 October 2005
Special
Type not classified · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2522160
13 July 2005
PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2425214
27 June 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2405454
16 May 2005
Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2359273
3 April 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2325433
13 December 2004
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2258008
27 November 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2248618
8 October 2004
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2216576
12 June 2004
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2095993
9 June 2004
Re-Inspection · ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2093417
4 February 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2000977
3 February 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2000107
10 December 2003
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1964226
Documentation › Logs/Records › Oil Record Book
Issued 15 February 2010
Resolved
Chief Engineer failed to record discharge of oil in engine room into the oil record book.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2010
Resolution: Counseled Chief Engineer on making sure that every accidental spill or discharge is noted in the Oil Record Book as per MARPOL 74/78 Annex I.
Engineering › Fuel Oil Service System › Tank
Issued 15 February 2010
Resolved
High Fuel oil drain tank overfilled due to a high level alarm failure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2010
Resolution: High Fuel oil drain tank overfill alarm is now operational.
Electrical › Electric Generation Source (emergency) › Generator
Issued 15 February 2010
Resolved
Switchboard located in front of emergency generator and the main switchboard speed control are missing non-conductive mats or grating in the front sides.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2010
Resolution: Non-conductive mats placed on Emergency Generator & Main Switchboard Speed Control.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 15 February 2010
No resolution recorded
As per [name withheld], Chief Engineer is required to maintain maintenance records under normal responsibilities. Chief Engineer could not provide OWS records as per manufacturer's requirements.
Action required: 705 - Other - as specified
Due 15 March 2010 — due date passed with no resolution recorded
Communications › Audible Communications › Horn/Whistle
Issued 14 July 2009
Resolved
The ship's whistle was inoperable.
Action required: 705 - Other - as specified
Due 14 July 2009
Resolved 14 July 2009
Resolution: Technician was on board to correct the ship''s whistle and provide proper paperwork to USCG prior to departure.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 25 October 2005
Resolved
Demonstrate proper operation of emergency fire pump prior to departure to the satisfaction of Class of a Coast Guard inspector. Fire Pump is unable to obtain suction
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2005
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 13 December 2004
Resolved
Provide Master statement which states vessel has its permanent affix label on ARPA radar IAW 33CFR164.38. This can be provided via fax, master statement, to be sent to local COTP/OCMI within 30 days.
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 8 January 2005
Resolution: Recieved master statement via fax that states vessel has its permanent affix label on ARPA radar IAW 33CFR164.38.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 12 June 2004
Resolved
Repair damaged rubber compensator for Main Diesel Engine (MDE).
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2004
Resolved 13 June 2004
Resolution: def corrected