Inspection record

Last inspected 13 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC5128
664615
Flag
UNITED STATES
Maury page id
psix-664615

Documentation record

Registered dimensions (L × B × D)82.6 ft × 28.0 ft × 11.0 ft
Registered tonnagegross 77 / net 52
ITC dimensions (L × B × D)82.6 ft × 28.0 ft × 11.0 ft
ITC tonnagegross 233 / net 77
BuilderROBERT E DERECKTOR INC · MAMARONECK, NY, UNITED STATES · built 2005
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portATLANTIC HIGHLANDS, NJ
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 2 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it77 - Convention (Subpart B), Net Ton
52 - Regulatory (Subpart C or D), Net Ton
233 - Convention (Subpart B), Gross Ton
77 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 25 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 25

13 April 2026 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8346799
8 May 2025 Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8131965
10 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8108918
30 May 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7922741
5 June 2023 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7703916
6 March 2023 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7645207
22 July 2022 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7513734
25 June 2021 Damage Survey · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7235663
18 June 2021 Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7232770
6 May 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7229521
24 February 2021 Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7145331
19 October 2020 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7079745
27 June 2020 Special · Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6991966
12 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6952193
12 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6952231
29 April 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6946142
14 May 2019 Special · Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6684984
2 May 2019 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6674475
10 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6660520
5 June 2018 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6417928
4 January 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6332674
10 May 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6149456
2 March 2017 Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6097502
12 June 2016 Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5907065
10 May 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5873386

Deficiency record · 14

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 April 2026 Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of power, to include vital systems. STBD generator shutdown intermittently, and does not stay on. Repair prior to passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2026
Resolution: Generator was repaired. Water pump and thermostat needed replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2024 Resolved
All electrical equipment including switches, fueses must be sutable for voltage and current utilized. the Digital Multimeter on the Main Electrical transfer power pannel was found not working. 46 CFR 183.220(b) - 50 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2024
Resolution: Provided invoice of new part and picture evidence of multi-meter working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 May 2024 Resolved
A vessel must have two independent means of controling each propulsion engine. Starboard engine backupcontrol was throwing error code #11. - 46 CFR 184.620(a) - 50 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2024
Resolution: Provided report from engine tech.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 5 June 2023 Resolved
46 CFR 185.602
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 27 June 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 June 2023 Resolved
EMERGENCY EXIT, KEEP CLEAR
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 27 June 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2023 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must be made with the approval of the cognizant OCMI. Provide repair plan for STBD side exhaust pipe installation and make each stage of the weld process available for inspection before vessel departs from the drydock facility.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 March 2023
Resolution: Inspected back gouge and final weld. Verified Dye Penetrant NDT. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2023 Resolved
The construction of the vessel must allow for the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to hull integrity. An inset and crack were found just below deck level on the port portion of the bow. Submit repair plan for rectification, and complete repairs once approved in accordance with USCG guidance. Complete prior to launching vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 March 2023
Resolution: Inspected back gouge and final weld. Verified Dye Penetrant NDT. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 March 2023 Resolved
The construction of the vessel must allow for the safe operation of the vessel in accordance with the terms of its Certificate of Inspection, giving consideration to hull integrity. Bolts were found missing on bow rub rail, leaving open penetrations in forward void space. Replace bolts prior to launching vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 8 March 2023
Resolution: Inspected bow internals. Verified bolts had been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure. Heavy corrosion was found on horn air and drain piping in the aft portion of the port and STBD engine rooms. Replace rotted flex hose sections and any piping underneath if wasted. Remove corrosion from air/drain piping and attest to current condition of piping.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 15 March 2023
Resolution: Recieved documentation showing piping had been cleaned and flex hose had been repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 March 2023 Resolved
Piping for fixed firefighting systems must be protected from corrosion. CO2 piping in aft portion of the port and STBD engine rooms was heavily corroded. Remove corrosion from piping and attest to current condition of piping.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 15 March 2023
Resolution: Corrosion was removed. No substantive damage was found. Piping was subsequently painted to limit future deterioration.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 March 2023 Resolved
Fire hazards and unsafe conditions including debris accumulation must be corrected. Required protective devices must be in satisfactory condition. Structural fire protection in aft portion of port and STBD engine rooms was deteriorated and accumulated heavy carbon build up. Cables for lowering structural fire boundary for the aft hatch to the port engine room were seized with corrosion. Replace damaged structural fire protection and release cable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 15 March 2023
Resolution: Pull cable was replaced. Structural fire protection was replaced and protective cladding was added to protect it.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 July 2022 Resolved
The discharge ends of vent pipers must be fitted with flame screens. Flame screen on starboard side vent hanging off.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 19 August 2022
Resolution: Operator submitted satisfactory pictures.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 June 2021 Resolved
Master reported grounding. Complete damage survey, report findings, provide repair plan if needed to the satisfaction of the local OCMI. Prior to Passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2021
Resolved 25 June 2021
Resolution: Damage survey completed. Both propellers were changed out and operational tested underway. See narrative for further details. AN7235663
Lifesaving › Inflatable Buoyant Apparatus › Capacity
Issued 12 June 2016 Resolved
Vessel is limited to 100 persons in total including crew. Vessel must have a reinspection when new IBA is insaled for 150 persons.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2016
Resolved 22 June 2016
Resolution: New 150 person IBA installed.