← All vessels
ETT-1000
ETT-1000 is a 2004 tank barge. The Coast Guard has recorded 27 inspections since 2004, most recently in June 2025, along with 8 deficiencies.
Records from 2004 to 2025. Most recent: inspection, 16 June 2025.
- Built
- 2004
- Last inspected
- 16 June 2025
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1151119
664856
Flag
UNITED STATES
Maury page id
psix-664856
Inspections, by type
…with no type recorded1
Years with a record
18 calendar years (2004–2025)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)195.0 ft × 35.0 ft × 12.0 ft
Registered tonnagegross 687 / net 687
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · PORT ALLEN, LA, UNITED STATES · built 2004
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it687 - Simplified, Net Ton
687 - Simplified, Gross Ton
687 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 27
16 June 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8160947
5 June 2024
Deficiency Check · Drydock Exam · Internal Structural Exam · COI Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7927653
17 May 2024
Annual Inspection · Permit to Proceed
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7914292
17 October 2022
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7579146
20 December 2021
Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7370707
22 December 2020
Deficiency Check · In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7115472
10 February 2020
Examination of Repairs · Annual Inspection · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6906288
16 July 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6752716
16 October 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6562274
30 August 2018
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6527634
31 October 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6298559
14 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6057575
19 September 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6004659
13 November 2015
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5762906
14 July 2014
Examination of Repairs · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4922031
6 January 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4778095
9 October 2012
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4457145
16 September 2011
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4146978
23 June 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3774430
25 May 2010
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3747088
28 July 2009
Internal Structural Exam · Hull Examination · Examination of Repairs · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3543217
18 October 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3082682
17 October 2007
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3081869
28 February 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2879473
25 May 2005
Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2368023
5 April 2004
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2038390
13 January 2004
Deadweight Survey · COI Inspection · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2001940
Deficiency record · 8
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 May 2024
Resolved
The Officer in charge of marine inspection may require a vessel to be dry docked or taken out of service to further asses the extend of damage to the hull. 7 feet of water ingress discovered in #2 void, vessel requires dry dock at Berry Bros in Morgan City, LA to determine cause of flooding. VSL to transit to Bourg facility to offload cargo, then proceed to Morgan City for reapairs upon first availability.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 22 December 2020
Resolved
The hull and deck houses shall be of steel or iron construction except that the pilothouse and decks over quarters may be constructed of wood. Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American bureau of Shipping or other recognized classification society.
Vessel has significant wastage of the original scantling.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 February 2020
Resolved
OCMI may require vessel to dry dock to further assess the extent of the damage and to effect permanent repairs.
Examination of Port and Starboard #2 and #3 void tanks revealed 5 feet of standing water from an unknown breach in the vessel's watertight envelope.
Vessel must remain at dock until the source of water ingress is identified, the extent of damage is assessed, a voyage plan is developed, and documentation is submitted to the Coast Guard. Upon submission the Coast Guard will provide authorization to transit to dry dock to effect repairs. 46 CFR 31.10-2(c)
Operations/Management › Vessel Activity › Loading
Issued 14 December 2016
Resolved
Vsl was loaded and operating outside its COI.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 September 2016
Resolved
COD provided to Marine Inspector was expired.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 20 September 2016
Resolved
COFR provided to Marine Inspector was expired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 October 2007
Resolved
Past due for annual insp.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 13 February 2004
Resolved
Provide copy of VRP approval letter.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.